Product information METPOINT®️ OCV completeThe METPOINT®️ OCV complete is an online oil vapour monitor for continuous measurement of residual oil vapour in compressed air (mg/m³). It provides real-time indication of oil vapour concentration and the ISO 8573 oil class to support process safety and compressed air quality monitoring.
Function and operationThe instrument uses a PID (photo-ionisation detector) with a UV lamp to detect hydrocarbon vapours. Measured values are temperature- and pressure-compensated. Continuous self-checks alternate measurements of sample air and an internally generated reference gas (produced by an integrated catalytic converter) to ensure reproducible zero-point control and long-term stability. Short measurement intervals and floating mean-value calculation reduce the impact of isolated peaks.
Key features- Continuous online monitoring of oil vapour concentration (mg/m³)
- Local display of current value, ISO 8573 oil class and system/component status
- PID sensor with temperature and pressure compensation
- Integrated reference gas generation via catalytic converter for automatic zero-point control
- Detection sensitivity down to approx. 0.001 mg/m³ (trace analysis for ISO 8573 class 1 < 0.010 mg/m³)
- Operating pressure range: 3 … 16 bar
- Standard measuring section example: DN50 (version for 16 bar available)
- Standard data transfer interfaces and alarm outputs for control-centre integration
- Robust industrial housing and flexible installation options
Advantages- Safe
- Reproducible accuracy through integrated reference gas generation
- Automatic monitoring of reference gas and sensor electronics
- Alarm message generation and transmission
- Reliable
- Wide operating pressure range (3 … 16 bar)
- Continuous online detection of oil vapour at trace levels
- Standardised data output to displays and control systems
- User-friendly
- Clear visualisation of measured values and system status
- Flexible installation and robust enclosure
Notes on sampling and measurementRepresentative sampling is essential for trace-level detection. For homogeneous flow, sample near the pipe centre. Mean-value formation over defined windows reduces false alarms from short peaks and ensures representative long-term monitoring data.
Technical specifications- Model: METPOINT®️ OCV complete
- Measurement principle: PID (photo-ionisation detector) with UV lamp
- Reference gas generation: integrated catalytic converter
- Detection sensitivity: down to approx. 0.001 mg/m³; supports ISO 8573 trace analysis (Class 1 < 0.010 mg/m³)
- Displayed values: oil vapour (mg/m³), ISO 8573 oil class, system status
- Pressure range: 3 … 16 bar
- Typical measuring section: DN50 (example configuration)
- Weight: 21 kg
- Product number / SKU: 4039709
- Interfaces: standard data transfer and alarm outputs