Thermostatic test chamber KBF 260
climatichumiditytemperature

Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature - image - 2
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature - image - 3
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature - image - 4
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature - image - 5
Thermostatic test chamber - KBF 260 - BINDER - climatic / humidity / temperature - image - 6
Add to favorites
Compare this product

Characteristics

Type
climatic, thermostatic
Controlled parameter
temperature, humidity
Test type
stability, for medicine stability
Application domain
for the pharmaceutical industry
Configuration
floor-standing, on casters
Light source
LED
Options and accessories
with temperature and climatic control, with constant temperature and humidity control, touchscreen-controlled
Other characteristics
accelerated, constant
Capacity

262 l
(69.21 gal)

Temperature

Min.: 0 °C
(32 °F)

Max.: 70 °C
(158 °F)

Power

1,400 W

Interior length

656 mm
(25.83 in)

Interior height

695 mm
(27.36 in)

Interior depth

575 mm
(22.64 in)

External length

930 mm
(36.6 in)

External height

1,396 mm
(54.96 in)

External depth

900 mm
(35.43 in)

Description

Product description
The KBF 260 is a constant climate chamber designed for ICH stability testing, long‑term, accelerated and stress tests in pharmaceutical applications. It meets ICH requirements for precision, programmability and documentation, offers flexible water supply options for varied installation sites and consumes up to 40% less energy than the previous model. Optional light modules enable conversion to an ICH photostability chamber or a plant growth chamber.

Benefits
  • Suitable for critical ICH stability tests due to high climate homogeneity even at full load
  • Reliable long‑term operation with proven compressor technology and stainless‑steel inner chamber
  • Ergonomic control: signal triangle with illuminated status and touchscreen program controller
  • Energy efficient: up to 40% lower consumption vs. predecessor thanks to inverter cooling technology

Important characteristics
  • Temperature range: 0 °C to +70 °C
  • Humidity range: 10% to 80% RH
  • APT.line™ preheating chamber technology
  • Climate‑neutral refrigerant R‑600a and inverter cooling unit
  • Door heating to prevent condensation; adjustable fan speed
  • Humidity control with capacitive sensor and steam humidification
  • HIT sandwich housing technology; stainless‑steel inner chamber; inner doors of metal‑oxide coated safety glass
  • Standard 2 stainless‑steel racks (max. 9), access port 80 × 45 mm with silicone plug
  • Floor‑standing with robust twin casters (front brakes) or optional height‑adjustable swivel casters
  • Internal data logger; measured values readable via USB; Ethernet, USB interfaces
  • Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
  • Optional light modules (ICH photostability) and LED plant growth modules

Technical specifications - Performance Data (Temperature)
Article numbers (examples): 9020‑0479, 9020‑0495
Designation examples: KBF260‑230V, KBF260UL‑120V
Option model: Standard
Temperature range: 0...70 °C
Max. heat compensation at 40 °C: 410 W

Technical specifications - Performance Data (Climate)
Temperature range with humidity: 10...70 °C
Humidity range: 10...80 % RH
Temperature uniformity at 25 °C / 60 % RH: 0.3 ± K
Temperature uniformity at 40 °C / 75 % RH: 0.2 ± K
Temperature fluctuation (25 °C / 60 % RH): 0.1 ± K
Temperature fluctuation (40 °C / 75 % RH): 0.1 ± K
Humidity fluctuation (25 °C / 60 % RH): 1.5 ± % RH
Humidity fluctuation (40 °C / 75 % RH): 1.5 ± % RH
Recovery time after 30 s door open at 25 °C / 60 % RH: 2 min
Recovery time after 30 s door open at 40 °C / 75 % RH: 3 min

Technical specifications - Electrical data
Rated voltage (examples): 220...240 V (standard), 120 V (UL variant)
Power frequency: 50/60 Hz
Nominal power: 1.4 kW
Unit fuse: 16.0 A
Phase (nominal voltage): 1~

Technical specifications - Dimensions and weights
Interior volume: 262 L
Net weight (empty): 188 kg
Load per rack: 40 kg; Permitted load: 200 kg
Wall clearance back: 100 mm; Side clearance: 180 mm
Width (net): 930 mm; Height (net): 1,396 mm; Depth (net): 900 mm

Technical specifications - Internal dimensions & fixtures
Interior width: 656 mm; Interior height: 695 mm; Interior depth: 575 mm
Inner doors: 1; Unit doors: 1
Number of shelves (std./max.): 2 / 9

Technical specifications - Environment & energy
Sound‑pressure level (25 °C / 60 % RH): 50 dB(A)
Energy consumption (25 °C / 60 % RH examples): 215 Wh/h (variant), 255 Wh/h (other variant)
Energy consumption (40 °C / 75 % RH examples): 230 Wh/h, 295 Wh/h (variant‑dependent)

Options and accessories (selection)
  • Reinforced inner chamber (permitted load with U rails 300 kg)
  • Mechanical door lock or electromechanical door lock (PIN via controller)
  • Interior climate‑resistant LED lighting
  • Height‑adjustable swivel casters; shipping pallet with unloading ramp
  • Access ports with silicone plug (30 / 50 / 80 / 100 mm; left, right, top)
  • Analog 4–20 mA output for temp/humidity; specimen temperature display (Pt100 sensor)
  • Calibration and qualification services (temperature & humidity calibration, IQ/OQ, certificates)
  • CO₂ gassing/regulation modules and CO₂ calibration (0–1% / 0–20%)
  • ICH light modules (VIS / UVA) with measurement certificate; LED plant light modules
  • Water supply options and PURE AQUA water preparation service

Characteristics / technical summary
  • Model: KBF 260
  • Article numbers (examples): 9020‑0479 (230 V), 9020‑0495 (120 V)
  • Temperature range: 0 °C to +70 °C; Humidity range: 10 % to 80 % RH
  • Interior volume: 262 L; Interior dimensions (W×H×D): 656 × 695 × 575 mm
  • Net weight (empty): 188 kg; Nominal power: 1.4 kW; Fuse: 16 A; 50/60 Hz; 1~
  • Temperature uniformity: 0.3 ± K (25 °C / 60 % RH); 0.2 ± K (40 °C / 75 % RH)
  • Humidity fluctuation: 1.5 ± % RH; Recovery times: 2 min (25 °C / 60 % RH), 3 min (40 °C / 75 % RH)
  • Refrigerant: R‑600a; Inverter cooling; Stainless‑steel inner chamber; Inner safety glass doors
  • Racks: 2 standard (max. 9); Data interfaces: Ethernet, USB; Internal data logger; Touchscreen controller
  • Safety: Class 3.3 independent temperature safety device (DIN 12880) with visual and acoustic alarms
  • Options: ICH photostability light modules, LED plant growth modules, CO₂ modules, calibration and qualification services

Exhibitions

Meet this supplier at the following exhibition(s):

Oslo Battery Days
Oslo Battery Days

24-25 Aug 2026 Oslo (Norway)

  • More information
    LAB-SUPPLY Dresden
    LAB-SUPPLY Dresden

    8-08 Sep 2026 Internationales Congress Center (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.