Type 3 surge protection unit DSLP1-120L/Y
type 2class Ifor LED lighting

Type 3 surge protection unit - DSLP1-120L/Y - CITEL - type 2 / class I / for LED lighting
Type 3 surge protection unit - DSLP1-120L/Y - CITEL - type 2 / class I / for LED lighting
Add to favorites
Compare this product

Characteristics

Type
type 3, type 2, class I
Applications
for LED lighting
Other characteristics
with fault indication, compact, thermoplastic, gas discharge tube, AC, DIN rail, single-phase, MOV
Voltage

Max.: 150 V

Min.: 120 V

Primary current

10 A

Open circuit voltage

10 kV

Description

Key features
  • SPD type 2 (or 3) for LED lighting
  • Very compact, low profile for luminaire integration
  • DIN-rail mounting (35 mm)
  • Screw-terminal or spring connection option
  • Status and end-of-life indication
  • Fail-safe disconnection from AC network at end of life
  • Compliant with EN 61643-11 / IEC 61643-11


Description
The DSLP range is an AC surge protection series designed for DIN-rail mounting to protect LED lighting systems. Devices are compact to allow integration inside luminaires and are available with screw-terminal or spring connection variants.

Electrical characteristics
  • SPD type (IEC): 2+3
  • Isolation class: I
  • Network: 120 V single-phase or 2-phase
  • AC system: TN
  • Nominal line voltage Un: 120 Vac
  • Max. AC operating voltage Uc: 150 Vac
  • Max. load current @25°C IL: 10 A
  • Temporary Overvoltage (TOV) 5 s UT: 120 Vac withstand (no disconnection)
  • Temporary Overvoltage (TOV) 120 min UT: 230 Vac disconnection (with or without safety disconnection depending on case)
  • Residual/leakage current to ground Ipe: None
  • Nominal discharge current In (15 impulses, 8/20 µs): 5 kA
  • Max. discharge current Imax (per pole, 8/20 µs): 10 kA
  • Combination waveform (IEC 61643-11) Uoc: 10 kV / 5 kA
  • Withstand on overvoltages (IEEE C62.41.1): 10 kV / 10 kA
  • Protection modes: Common and Differential mode
  • Protection level Up L/N @ In (8/20 µs): 1.5 kV
  • Protection level Up L/PE @ In (8/20 µs): 1.5 kV
  • Admissible short-circuit current Isccr: 10 000 A


Mechanical characteristics
  • Technology: MOV + GDT
  • Network connection: Screw terminal up to 2.5 mm²; earth conductor 2 mm² (recommended length 60 cm)
  • Mounting: Symmetrical DIN rail 35 mm (EN 60715)
  • Housing material: Thermoplastic UL94 V-0
  • Operating temperature Tu: -40 to +85 °C
  • Ingress protection: IP20
  • Fail-safe mode: Disconnection from AC network
  • Thermal disconnector: Internal
  • End-of-life indicator: Green LED OFF with AC cut-off
  • Operation indicator: Green LED ON
  • Dimensions: see manufacturer diagram
  • Weight: 0.062 kg


Compliance
EN 61643-11 / IEC 61643-11


Associated disconnectors
  • Internal thermal disconnector
  • Installation residual-current device (if present): Type 'S' or delayed


Technical specifications
  • Model reference: DSLP1-120L/Y
  • SPD type: IEC 2+3
  • Supported network: 120 V single-phase or 2-phase
  • Nominal line voltage (Un): 120 Vac
  • Max. operating voltage (Uc): 150 Vac
  • Max. line current (IL): 10 A
  • Nominal discharge current (In, 8/20 µs): 5 kA (15 impulses)
  • Max. discharge current (Imax, 8/20 µs): 10 kA
  • Protection level Up (L/N and L/PE @ In): 1.5 kV
  • Combination waveform withstand (IEC): 10 kV / 5 kA
  • IEEE surge withstand: 10 kV / 10 kA
  • Internal technology: MOV + GDT
  • Mounting: DIN rail 35 mm (EN 60715)
  • Ingress protection: IP20
  • Operating temperature: -40 to +85 °C
  • Housing material: Thermoplastic UL94 V-0
  • Weight: 0.062 kg

Catalogs

No catalogs are available for this product.

See all of CITEL‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.