Controls the position of hazardous machine doors/cases with integrated self-checking Contactless coded sensor with electronic technology and relays IP68 PA6 / IP69K INOX316L Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1 Performance level and category with AWAX controller: Cat 4 up to PL=e Integrated safety level: SIL 2 according to IEC 61508
Level of performance without an external controller
PL = d
Level of performance with AWAX controller
up to PL = e
Safety category without an external controller
3
Safety Integrity Level
SIL2
Cycle after dangerous failure
B10d = 2,000,000 at 2A
Max. activation distance
10 mm, 2 mm hysteresis
Security contacts / diagnostics
AMX5 / AMX5CM12 : 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary
Security contacts AMX4
2 x NO 2A/48V redundant
Security contacts / diagnostics AMX3
1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
Detection encoding
mono-code inviolable
Indicator
LED indicates code recognition
Reset
automatic
Attachment
4 tamper-proof M4 screws (optional ref: BH4)
Mounting position
2 (double wall brackets)
Material
Electrical Connection
Water resistance
IP 68 (PA6) or IP 69K with stainless steel - new generation
Temperature
-25°C to +60°C
Marking
PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
Certification
TÜV Rheinland 01/205/5238/12
License Test
Mark 968/EL 214.01/12