SIL2 2-Wire Passive/Active HART® Tx Current RepeaterThe Current Repeater Power Supply X1-NIS-AI-02 module is a high integrity analog input interface suitable for applications requiring SIL 2 level in safety related systems for high risk industries. It provides an isolated supply for energizing conventional two-wire passive 4-20 mA transmitters, while repeating the current to the system card. Two-wire active transmitters are also supported. The circuit allows bi-directional HART® communication for both passive and active devices. The module always sinks current and the Termination Board extends its use to source loops. An out-of-range current fault according to IEC 60947-5-6 NAMUR NE 43 standard is available with limits configurable through the optional Gateway. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction lever mechanism. This product requires a dedicated Termination Board.FEATURESSIL 2 / SC 3Installation in Zone 2 / Division 2Loop disconnection to ease maintenance operations4-20 mA 2-wire Active-Passive InputHART® compatibleOut-of-range fault according to IEC 60947-5-6 NAMUR NE 43Input and Output short circuit proofHigh AccuracyThree port isolation, Input/Output/SupplySTATUS: ACTIVECHANNELS: 1GeneralPower Dissipation0.55 W (passive Tx), 1.05 W (active Tx) @ 24 Vdc with 20 mA, 24 Vdc + 250 Ω output, typical.System SupplyVoltage24 Vdc nom (18 to 30 Vdc).Current Consumption23 mA @ 24 Vdc with 20 mA, typical.System OutTypeCurrent 4 to 20 mA. The module always sinks current and the Termination Board extends its use to source loops.Response time≤ 20 ms (4 to 20 mA or 20 to 4 mA).Current limitation26 mA typical.Maximum load600 Ω.Maximum voltage30 V.Minimum voltage15 V (including series resistance voltage drop).Field InTypeCurrent 4 to 20 mA, passive or active Tx.Passive Tx line voltage20 V minimum @ 20 mA.Active Tx voltage drop6.5 V maximum @ 20 mA.Current limitation26 mA typical.FaultTypeAn out-of-range fault with configurable limits is available on the common fault line.PerformanceRef. Conditions24 V supply, 24 V + 250 Ω output, 23 ± 1 °C ambient temperature.Linearity accuracy≤ ± 20 µA.Calibration accuracy≤ ± 20 µA.Temp. influence≤ ± 2 µA/°C.IsolationTest VoltageField In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.Environmental conditionsOperating temperaturetemperature limits –40 to +70 °C.Storage temperaturetemperature limits –45 to +80 °C.MountingTypeOn custom Termination Board.Weightabout 55 g.DimensionsWidth 10 mm, Depth 80 mm, Height 120 mm.Technical Specifications:Power Dissipation: 0.55 W (passive Tx), 1.05 W (active Tx) @ 24 Vdc with 20 mA, 24 Vdc + 250 Ω output, typical.System Supply Voltage: 24 Vdc nom (18 to 30 Vdc).Current Consumption: 23 mA @ 24 Vdc with 20 mA, typical.System Output: Current 4 to 20 mA, always sinks current, Termination Board extends use to source loops.Response time: ≤ 20 ms (4 to 20 mA or 20 to 4 mA).Current limitation: 26 mA typical.Maximum load: 600 Ω.Maximum voltage: 30 V.Minimum voltage: 15 V (including series resistance voltage drop).Field Input: Current 4 to 20 mA, passive or active Tx.Passive Tx line voltage: 20 V minimum @ 20 mA.Active Tx voltage drop: 6.5 V maximum @ 20 mA.Fault: Out-of-range fault with configurable limits on the common fault line.Linearity accuracy: ≤ ± 20 µA.Calibration accuracy: ≤ ± 20 µA.Temperature influence: ≤ ± 2 µA/°C.Isolation Test Voltage: Field In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.Operating temperature: –40 to +70 °C.Storage temperature: –45 to +80 °C.Mounting: On custom Termination Board.Weight: about 55 g.Dimensions: Width 10 mm, Depth 80 mm, Height 120 mm.