Any measurement range from 1 up to 100mH2O
Output Signal: 4~20mA (2-wires)+HART
The LG-20C features advanced circuitry and temperature compensation technology, which converts the liquid level measurement into a standard 4~20mA output signal. This offers strong anti-interference capability, low thermal error, and high stability, providing excellent measurement accuracy and sealing performance.
Preferred Areas of Use
-Water / filtrated sewage
-Ballast Water Tank Level Monitoring for Vessels
-Deep Well and Groundwater Monitoring
-Sewage and Flood Discharge System Monitoring
-Water Level Measurement of Rivers, Lakes, and Reservoirs
-Factory Water Tank Level Monitoring
Technical Data
Measurement Range: 1...100mH2O
Accuracy Level: 0.2
Thermal Error: ≤±0.2% F.S / 10℃ (Within the range of temperature compensation)
Thermal Compensation Range: 0~50℃
Long Term Stability: ≤±0.1% / URL (12months)
Response Time: 0.25s
Overload Capacity: 150%~200% full span
Working Temperature: -20~80℃
Power Supply: 10~32V DC [4~20mA (2-wires), HART ]
Load Resistance: RL ≤(Us-Umin) / 0.026
Probe Material: SS316L, standard
Probe Protection Class: IP68
Diaphragm Material: SS316L, standard; and Hastelloy C-276, Tantalum on option
Cable Shield: PU and PTFE
Cable Length: 5M standard; maximum length 100M