1. Inquire to get latest price, goods can be finished within 2-3 working days.
2. EFP series is no dead-zone safety light curtain, in accordance with EU type 4 safety standards.
3. Adopting the internal MCU redundancy design, the safety light curtain has periodic self-inspection & mutual check function. Redundantdual output loop to ensure high security.
Parameter of safety light curtain
• Reference standard :
• EN 61496-1 (Type 4 ESPE)
• EN 61496-2 (Type 4 AOPD)
• EN ISO 13849-1 (Category 4、PLe)
• Safety level : Type 4
• Supply voltage : DC24V±20%
• Capacity : <5W
• Beam space : 10mm, 20mm
• Resolution : 15mm, 25mm
• Beams :
• 10mm beam space:16, 20……160
• 20mm beam space: 8, 10……80
• Protective height : Protective height =(N-1)*beam gap,N is beam quantity.
• Wave length : 940nm
• Response time : Response time =(N*0.1ms)+0.4ms, N is beam quantity.
• Type of output(OSSD) : PNP/NPN semiconductors,current <200mA max, residual voltage: 1 V max. leakage current: 1mA max. (Expect voltage influenced by lengthen wire).
• Protective circuit : Overload voltage protection, power supply reverse polarity protection, over current protection.
• Sensing distance : 0.1~2m、0.1~5m (remark: If have light reflection, please let us know)
• Anti-optical interference : 10000Lux
• Sensing method : Through-beam type
• Synchronization : Wire synchronization
• Enclosure material : Aluminum alloy
• Enclosure rating : IP65
• Housing cross-section : 30*28mm
• Vibration resistance : 10 Hz~55 Hz, amplitude 0.35±0.05mm, 20 times each in X, Y, Z direction