1. Design according to ISO13849-1 (Category 4 Ple);
2. Relay output: 3NO and 1 NC auxiliary contacts;
3. Inside circuit with cross-diagnose monitoring function;
4. Visualized status indicator for easy diagnoses;
5. Input power overvoltage protection.
Standard level
• Reference standard : ISO 13849-1
• Safety level : ISO 13849-1 Category 4/Ple
Electric parameter
• Power supply : DC24V±10%
• Consumption : <3W
• Response time : <20ms
• Suction buffer time : <100ms
• Power-on restart time : <1s
• Protective circuit : Overvoltage protection, reverse polarity protection
• Safety input : Two hand button signal
• Input synchronization : ≤500ms(Typical data200ms)
• Safety output : 3NO contacts, and 1 NC auxiliary contacts
• B10 data : Rated load: 400,000 times, low load: 2,000,000 times
• Contact capacity : AC15:5A/250V;DC13:6A/24V
• Electric lifetime : ≥100,000 times (1NO:5A 250VAC,Resistive load)
• Mechanical lifetime : ≥10,000,000 times
Environment
• Vibration resistance : Frequency 10Hz-55Hz, amplitude 0.35±0.05mm, 20 times each in X,Y and Z direction
• Impact resistance : Acceleration 10g, pulse duration 16ms, 1000 times each in X, Yand Z direction
• Working temperature : -10℃~+55℃
• Storage temperature : -40℃~+85℃
• Protection level : Enclosure: IP40 Terminal: IP20
Installation/ Structure
• Installation : 35mm DIN navigation
• Wire size : 0.2~2.5mm²
• Size : 117 x 100.6 x 22.5