Product OverviewA urinal flush valve designed for commercial and public restroom systems to control flushing cycles, reduce water consumption and provide reliable performance across variable inlet pressures. Available in manual, sensor-operated and solenoid-controlled versions, the WL2862 is engineered for longevity and easy maintenance.
Main Features- Controlled flush volume for water savings.
- Fast response: on ≤ 0.15 ms, off ≤ 0.5 ms.
- Low-noise operation suitable for high-traffic environments.
- Corrosion-resistant materials: stainless threads, POM components, brass solenoid housing.
- Leak-tight sealing and simple serviceability (filters, diaphragms replaceable).
- Available modes: manual, sensor (automatic), solenoid.
Datasheet (key parameters)Product name: Urinal Toilet Flush Solenoid Valve
Model: WL2862
Rated Voltage (V): DC12V
Type: Normally closed
Response Time (ms): on ≤ 0.15; off ≤ 0.5
Working Pressure (MPa): 0.02-0.8
Flow characteristics: 0.05 MPa ≥ 12 L/min; 0.1 MPa ≥ 17 L/min; 0.8 MPa ≥ 35 L/min
Medium Temperature (℃): 1-75
Medium: Water (potable)
Electrical Resistance (Ω): 27 Ω ± 0.5
Lifespan (cycles): ≥ 500,000
Materials: stainless threads, POM parts, brass solenoid components
ApplicationsDesigned for hotels, airports, shopping centers, schools, hospitals, industrial facilities and other high-traffic public restrooms. Sensor versions support water-efficient and green building projects. Also suitable for low-pressure irrigation and other water-control uses where applicable.
Advantages & Disadvantages (summary)- Advantages: consistent flush performance, improved hygiene with sensor models, water savings, configurable settings, robust for commercial use.
- Disadvantages: higher initial cost for automatic/sensor variants, periodic maintenance required, dependence on power or batteries for sensors, misconfiguration may cause over-flushing.
Troubleshooting (common issues & remedies)- No water flow: check supply valve, inlet filter and system pressure.
- Continuous flow: inspect and replace diaphragm/seal, clean internal debris, test/replace solenoid if needed.
- Weak flush: increase supply pressure if possible, adjust flow regulator, check piping for clogs.
- Leaks: tighten fittings, replace O-rings or damaged parts, replace valve body if cracked.
- Sensor faults: verify power/batteries, clean sensor lens, replace sensor module if defective.
- Loud operation: check pressure regulator, secure internal components.
Technical specifications- Model: WL2862
- Control types: manual / sensor (automatic) / solenoid
- Rated voltage (solenoid): DC 12 V
- Configuration: normally closed
- Response time: on ≤ 0.15 ms; off ≤ 0.5 ms
- Working pressure range: 0.02 – 0.8 MPa
- Flow performance: ≥12 L/min (0.05 MPa) to ≥35 L/min (0.8 MPa)
- Operating medium temperature: 1 – 75 ℃
- Medium: potable water
- Electrical resistance: 27 Ω ± 0.5
- Durability: ≥ 500,000 cycles
- Materials: stainless threads, POM plastic parts, brass solenoid components
- Typical uses: urinal/toilet flush valve, low-pressure irrigation and similar water control applications