Process temperature: -20 °C - 60 °C
Precision: 0.4 %
Repeatibility: 0.1 %
... ELECTROMAGNETIC FLOWMETER
HIGH-PRECISION FLOW MEASUREMENT FOR WATER NETWORKS WITHOUT EXTERNAL POWER SUPPLY
The M5000 self-powered electromagnetic
flowmeter is designed for accurate ...
FUJI ELECTRIC France
Process temperature: -273 °C - 200 °C
Precision: 1 %
... open collector contacts
APPLICATIONS
- This flowmeter is
FUJI ELECTRIC France
Precision: 0.3 %
Repeatibility: 0.1 %
... ELECTROMAGNETIC
FLOWMETER M1000
- Bidirectional flow measurement for liquids with conductivity above 5 μS/cm, and above 20 μS/cm for demineralized water.
- Accuracy of ± 0.3% of measured flow
FUJI ELECTRIC France
Process temperature: -273 °C - 200 °C
Precision: 1 %
... FIXED ULTRASONIC FLOWMETER TIME DELTA-C – CONVERTER – FSV IP66
NON-INTRUSIVE FLOW MEASUREMENT TO IMPROVE INDUSTRIAL PROCESS RELIABILITY
The fixed ultrasonic
flowmeter ...
FUJI ELECTRIC France
Process temperature: -40 °C - 200 °C
Precision: 1 %
... strong>FIXED ULTRASONIC
FLOWMETER TIME DELTA-C – FSV IP67 CONVERTER
HIGH-PRECISION NON-INTRUSIVE FLOW MEASUREMENT FOR DEMANDING INDUSTRIAL ENVIRONMENTS
The Time Delta-C fixed ultrasonic ...
FUJI ELECTRIC France
Precision: 1 %
... FIXED ULTRASONIC FLOW METER FSV-L FOR FLOW MEASUREMENT AND ENERGY METERING
AN EXTENDED SOLUTION FOR ACCURATE LIQUID FLOW MEASUREMENT AND ENERGY PERFORMANCE ...
FUJI ELECTRIC France
Process temperature: -20 °C - 80 °C
Repeatibility: 1.5 %
... ULTRASONIC
FLOWMETER M-
FLOW PW – FLR CONVERTER
HIGH-PRECISION SOLUTION FOR LIQUID FLOW MEASUREMENTHIGH-PRECISION
The Fuji Electric M-
Flow PW Fixed ...
FUJI ELECTRIC France
Process temperature: 120 °C - 180 °C
Process pressure: 1 bar - 9 bar
... FIXED ULTRASONIC STEAM FLOWMETER – CONVERTER – FSJ
HIGH-PRECISION STEAM FLOW MEASUREMENT WITHOUT PERFORMANCE COMPROMISE
The FSJ fixed ultrasonic steam
flowmeter ...
FUJI ELECTRIC France
Process temperature: -15 °C - 85 °C
... ULTRASONIC COMPACT INTEGRATED FLOWMETER S- FLOW – FSZ A PRECISE AND COMPACT SOLUTION FOR FLOW MEASUREMENT The S- Flow – FSZ ultrasonic flowmeter is a high-precision ...
FUJI ELECTRIC France
Volumetric flow rate: 0.2 m³/h - 848.2 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... Inline Flow Sensor for Compressed Air and Gases Versatility The modular and compact EE741 is dedicated for accurate metering and monitoring of compressed air and technical gases such as O2, N2, Ar or CO2 in DN15 to DN50 pipes. Measuring ...
Volumetric flow rate: 1.7 m³/h - 263,350 m³/h
Process pressure: 0 bar - 16 bar
... Insertion Flow Sensor for Compressed Air and Gases DN50 - DN700 (2" - 28") The EE776 employs the thermal mass flow measurement principle and is suitable for pipe diameter DN50 (2") to DN700 (28"). It is ideal for monitoring ...
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the ...
Pulsar Measurement
Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
... Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer effective clamp-on ...
Pulsar Measurement
Process temperature: -20 °C - 50 °C
... applications. Area-Velocity Measurement / Open Channel Flow Measurement with No Primary Measuring Device FlowCERT can be combined with a MicroFlow for velocity measurement. Or for area-velocity flow measurement, ...
Pulsar Measurement
Volumetric flow rate: 0 m³/h - 32,979.6 m³/h
Process temperature: -40 °C - 121 °C
Process pressure: 500, 230, 285 psi
... The MDot™ is one of the most technically advanced gas flow meters specifically designed for water and wastewater. An innovative Thermal Mass Flow Meter and Temperature Transmitter that ...
Pulsar Measurement
Process temperature: -40 °C - 65 °C
Precision: 0.25 %
Repeatibility: 0.1 %
... The OCF 6.1 is an open channel flow meter that doubles as a tank level meter, making it a perfect solution for both non-contacting flow measurement and level measurement. The non-contacting ...
Pulsar Measurement
Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -40 °C - 150 °C
Precision: 1 %
... from one transducer to another. The time between transmitted and received signals is measured by the flow meter. Mount the TTFM 6.1 Transit-Time Flow Meter ultrasonic transducers on the ...
Pulsar Measurement
Process temperature: -20 °C - 50 °C
Precision: 0.25 %
Repeatibility: 0.1 %
... differential level and volume monitoring. Each channel is user-configurable to operate independently either as an open channel flow meter, a pump control system, or as a level and volume monitoring unit for liquids and ...
Pulsar Measurement
... CDI 5400 flowmeters make localized metering of air usage a practical way to manage a compressed-air system. Thermal-dispersion mass- flow technology gives the meter sensitivity to low leakage flows, ...
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group