Low operating costs, modern design and up to 65 % less refrigerant, are surely enough reason to consider the arctic starrefrigeration dryer range when making a decision on your next dryer purchase requirement!
29 models with flow rates from 25 m3/h (15 cfm) to 6600 m3/h ( 3885 cfm) covers the majority of compressor manufacturers installations. The arctic stardryers are part of a complete product range of refrigerant air driers. We can supply larger sizes and industrial dryers to work at pressures up to 50 bar.
-Also available 60 Hz version (12 m³/min / 7 cfm - 6600 m³/m / 3835 cfm).
-Higher volumes and high pressure units on request!
Phone: 0049 2054-934-0 (Germany)
-Standard equipment:
condensate drains form the standard
equipment of the AS refrigeration dryers.
Generally all the refrigeration dryers of the series are
equipped with a refrigerant which is not harmful to ozone.
AS 0012 to AS 0540 include required accessories such as
dew-point indication and on/off switch.
AS 0660 to AS 6600 are fitted with a microprocessor
controller and a diagrammatic view of the air and refrigeration circuit.
|
|
Easy Installation
Plug and play concept
Single electrical connection
All units pre-commissioned
Self regulating.
Minimal maintenance
Long service intervals
Few component replacements
Ergonomic design for fast access to key components.
Significant cost savings
Increased reliability and lifetime of tools and equipment
Reduced professional pipe work leaks, meaning reduced energy bill
Fewer repairs to tools, machines and pipe work
Less inconvenient breakdowns and stoppages
Minimal chance of product spoilage through moisture carryover
|
|
FD : "The industry benchmark for refrigerant industrial dryers"
Clean and dry pneumatics: it is vital to power up your busy production environment. Containing moisture, aerosols and dirt particles, untreated compressed air poses a substantial risk as it can damage your air system and end product.
Incorporating unique, patented technological innovations and extra energy-saving options, Atlas Copco's FD refrigerant dryers provide you with the clean, dry air you are in need of to expand the life of your equipment and ensure the quality of your end product.
Dry air at any time
Space-Saving, Easy Installation
Advanced control & Monitoring solutions
Supreme energy efficiency
Powerful & reliable
Efficient water separation
Unique & effective heat exchanger suppliers technology
Proven peace of mind
Built for endurance
|
|
| The ambient air given off by any compresser always contains water vapour. This depends on the ambient temperature and the relative humidity. When air is compressed, the volume decreases proportionally. This results in condensate formation. Condensate causes corrosion in compressed air pipe line, increases tool wear, faults in air controls, delayed response time, expensive down time, etc. Compressed air driers are used to separate the condensate and contaminants. |
|
PNC Series
(4,000 - 20,000 scfm)
PNC Series Refrigerated dryers are ideal for continuous-duty applications. Non-cycling operation uses refrigerant manufacturers of control valves to maintain dew point stability. Capacity unloaders provide energy savings at specific levels of system load.
Environmentally friendly "NO CFC" refrigerants and durable semi-hermetic refrigerant compressors for long life
Fully automatic, non-cycling refrigeration control systems provide energy efficieny and the lowest possible dew point under all rated design conditions
Non-clogging automatic condensate drain cocks for fast, reliable condensate removal
Rugged structural steel frame construction for component protection and system integrity
|
|
DryStar (0-200 cfm):
The economically priced DryStar cools pneumatics by mechanical refrigeration to a 33-39 degree F pressure dewpoint. Condensed water is removed through an automatic industrial drain cock. Featuring low power consumption, DryStar professional dryers are simple to install with a quick fit electrical connection. Each DS dryer uses environmentally friendly R134A refrigerant.
Ratings are based on 100 degree F inlet air temperature and 100 psiG inlet air pressure.
Maximum inlet temperature is 140 degree F, maximum pressure is 232 psiG.
DryStar (DS) Refrigerated dryers:
IR%u2019s DS: An economical product that can reduce compressed air dew point temperatures below 40F.
Easy to install and nearly maintenance free.
A GP pre-filter should be utilized to reduce contaminants in your system. |
|
Drying Systems - 201 Series
The Ultra Air 201 Series Refrigerated dryer provides just that: a competitively priced industrial dryer with consistent pressure dew points (33°F - 39°F), delivered quickly and backed by a five-year warranty.
Every dryer is designed with energy savings in mind. All components are properly sized to assure that no energy is wasted. Ample inside professional cabinet space and easy access components make for simple future maintenance and adjustments. Since only top quality components are utilized, the 201 Series will give the customer years of uninterrupted service.
Standard Specifications:
Maximum Pressure: 225 PSIG (16 BAR)
Minimum Pressure: 29 PSIG (2 BAR)
Maximum Temperature: 158 F
Voltage: 115/1/60, 208-230/1/60, 220-240/1/50
Power Consumption: 12 Watt Max
Pre-filter Rating: 0.3 Micron (Coalescer)
Afterfilter Rating: 3.0 Micron (Particulate)
Cycle Time: 4 Minutes
Purge Loss: 12%
Air Outlet Conditions: Dry air down to -40 F Dew Point
Power Cord: Standard 8 ft |
|
Refrigerated Compressed air drier
1). Air-cooling refrigerated suppliers of air dryer
Inlet temperature:
Normal inlet temperature: less than 45 celsius degree
High inlet temperature: less than 80 celsius degree
Cooling method: Air-cooling
Ambient temperature: less than 38 celsius degree
Dew point: 2~10 celsius degree
Refrigerant: R-22 /R-134a
Inlet pressure: 0.2~1.0MPa
Pressure drop: less than 0.02MPa
2). Water-cooling refrigerated air professional dryer
Inlet temperature:
Normal inlet temperature: less than celsius degree
High inlet temperature: less than celsius degree
Cooling method: Water-cooling
Dew point: 2~10 celsius degree
Refrigerant: R-22 /R-134a
Inlet pressure: 0.2~1.0MPa
Pressure drop: less than 0.02MPa
Cooling water inlet temperature: less than 32 celsius degree
Cooling water inlet pressure: 0.2~0.4MPa |
|
Solid performance
_Steady pressure dew point
_No freezing of condensed moisture
_No chance of moisture entering the compressed air system.
Simple reliability
_Quality components, generously sized
_Simple and proven design
_Effective control system (hot gas bypass). |
|
| The extremely efficient design ensures cost-saving and reliable operation. The technical highlights include: vertical heat exchanger suppliers arrangement with condensate flow from top to bottom (correct physics!), stainless steel demister for reliable separation, and a large calming space to prevent condensate carry-over. |
|
In classical applications where the air network is not below 0°C or 32°F, the technology of the refrigeration industrial dryer with dew point of 3°C (37.4°F) completely eliminates the water contained in the pneumatics.
Using a DW dryer is an guarantee to produce compressed air of the best possible quality
|
|
Solid performance
- Steady pressure dew point
- No freezing of condensed moisture
- No chance of moisture entering the pneumatics system.
Simple reliability
- Quality components, generously sized
- Simple and proven design
- Effective control system (hot gas bypass).
Easy Installation
- Plug and play concept
- Single electrical connection
- All units pre-commissioned
- Self regulating.
Minimal maintenance
- Long service intervals
- Few component replacements
- Ergonomic design for fast access to key components. |
|
During the design of this line of refrigeration suppliers of air dryers one theme was kept central: energy efficiency.
When using the level controlled condensate drains (standard as from EDU 500 upwards) an unnecessary loss of expensive compressed air is prevented. Furthermore the refrigeration air professional dryers are supplied with the unique Trisab aluminium heat exchanger manufacturers.
The specific advantages are as follows:
Efficient and low energy cooling of the compressed air via the two-stage heat exchanger.
Due to relatively large flow channels the pressure drop is extremely low and the refrigeration air dryer is not easily affected by pollution.
The system is supplied with an overloading reservoir thus ensuring a constant pressure dew point, even in varying load and intensive use.
Optimal condesate separation.
|
|
| ... products without technical information |
| |
|
|