Total solution for all application and conditions with 7 different modules:
TOC-determination based on the known
Combustion catalytic oxidation / NDIR-detection method
- Stand alone operation
- PC-Controlled
- Economic Module
TOC-determination based on the new developed
Wet chemical oxidation / NDIR-detection method
- Stand alone operation
- PC-Controlled
|
|
TOC is used in a variety of applications from management of waste water treatment plant influent and effluent, to drinking water supply management and monitoring of impurities in process and natural waters. And the range of applications in which this type of on-line technology is used is expected to continue expanding.
In addition, because nitrogen is considered to be one of the factors which contributes to the over-proliferation of organisms in enclosed bodies of water, management of these public water sources and of treatment plant influent and effluent also includes demand for monitoring of nitrogen levels.
|
|
|
|
|
|
TOC/TNb analysis for all matrices
The new generation of our TOC analyzers represents the consistent development of the successful concept of our proven TOC/TNb systems. Beside catalytic high-temperature oxidation at up to 1,000° C and high-sensitivity NDIR and chemiluminescence detectors, this concept is based on innovative technological solutions for signal analysis (VITA technology) and high particle-handling capacity (special valves and septum-free injection heads).
The multi N/C series consists of five analyzers covering the range from budget-priced, but powerful instruments for environmental analysis to high-sensitivity, extremely flexible systems that are suitable for most diverse applications, such as the analysis of ultrapure water, drinking water, surface water, waste water, slurry and solids. With the multi N/C 2100, another innovation has joined the series: a "double-furnace? system providing TOC analysis of liquid and solid samples without requiring an additional solids module.
multi N/C UV HS: a TOC analyzer with UV-supported wet-chemical digestion principle ? an ideal tool for the analysis of ultrapure water, drinking water and similar samples Internationally, the diversity of TOC analyzers provided is unique and ensures the right technical solution for every possible application.
|
|
|
|
|
|
IL 550 TOC Analyser - Ready for the toughest challenge
Liquids and solids, particle- and salt-containing samples - all of them are no problem for the IL 550 TOC-TN with high-temperature digestion.
The variable injection volume of 10 to 500 µl enables a volume-dependent calibration to be carried out without time-consuming preparation of different standards.the VITA software ensures long-term stable calibration. The wide measuring range of 0.05-30,000 mg/l TOC and 0.1-100 mg/l TN makes precise analysis possible without dilution.
For the serial analysis of solids, the HSC 1300 module is used with sample weights up to 3 g!
IL 500 TOC Analyser - Seriously sensitive
The IL 500 TOC analyser with UV persulphate digestion is especially suitable for the automatic analysis of TOC in the low measuring range, as samples of up to 20 ml can be injected. Three measurement channels give the instrument its especially wide measuring range from 0.002 to 10,000 mg/l. The OMNITOC software is very easily understandable
and can be operated intuitively.
|
|
|
|
|
|
The new Sievers InnovOx Laboratory Total Organic Carbon (TOC) Analyzer can run thousands of diverse, high-TOC samples—including brine and cellulose—with unprecedented uptime. The Sievers InnovOx offers unmatched oxidation robustness, dynamic linear working range, and calibration curve stability for industrial process, wastewater and environmental water samples. It is compliant with EPA, Standards Methods and ASTM regulatory methods.
The tough and reliable Sievers InnovOx uses a patent-pending Super Critical Water Oxidation (SCWO) technique to achieve superior TOC recoveries regardless of organic compounds and particulate impurities in the sample. In addition, this new process removes all oxidation byproducts and sample between each analytical run, eliminating the need for frequent maintenance.
The Analyzer uses an enhanced Non Dispersive Infra Red (NDIR) design, which has no moving parts, to allow superior linear response. The NDIR has a dynamic detection range of 0.5 to 50,000 ppm, and is capable of measuring Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), and Non-Purgeable Organic Carbon (NPOC.
The Sievers InnovOx has a Web interface for easy, remote monitoring, an intuitive touch-screen display, and three convenient USB ports. The InnovOx is easy to set up and operate and requires no external carrier gas. The InnovOx is ready to run immediately, as it needs no prior furnace heat-up or stabilization. Maintenance is minimal, keeping total cost of ownership low. Preventive maintenance and calibration are only needed every 6 months.
|
|
ANATEL A-1000
TOC Analyzer
Ideal for monitoring ultrapure water production and measuring the influent and effluent water at rinse stations to ensure that cleaning is complete. Monitors both hot and cold water to detect and report the most rapid TOC changes quickly.
Detection limits from 0.05 to 1999 ppb TOC
Patented stopped flow and photocatalytic oxidation
Convenient serial, analog, and digital interfacing
|
|
|
|
|
|
AOX/TOX Analyzer; DEXTAR
The DEXTAR analyzer is designed for cost effective AOX and TOX analysis in a wide range of water and solids matrices.
Product Detail
Organic Halogens pose a threat to the environment and mankind. Most substances, which include organic halogens, are toxic, carcinogenic, persistent and bio-accumulative.For this reason regulatory authorities imposes maximum permissible levels of these compounds in soil and water.
Microcoulometry is the best reference method for the determination of total organic halogen content in environmental samples; it fully complies with ISO, DIN, CEN and EPA methods. These methods lead to fast, quantitative, economical and absolute results. De DEXTAR analyzer is ideal for laboratories performing a low number of AOX/TOX samples.
Applications:
• Drinking water
• Surface water
• Ground water
• Effluent water
• Influent water
• Waste water
• Cooling water
• High salt content water
• Process water
• Pulp & paper products
• Soil & sediment
• Sludge
• Waste oil
Options:
• The DEXTAR can be used as a horizontal or vertical sample introduction system
|
|
|
THORNTON Total Organic Carbon instrumentation provides fast, continuous measurement of ppb-level organic contamination using proven UV oxidation and conductivity measurement technology. It meets pharmaceutical USP , and EP 2.2.44 as well as semiconductor ultrapure water monitoring requirements.
|
|
|
|
|
|
Sievers 900 Laboratory
The Sievers® 900 Laboratory Total Organic Carbon (TOC) Analyzer offers superior productivity for laboratory TOC measurements. Automated calibration and validation procedures, faster analysis time, automated reagent adjustment, and the high-capacity 900 Autosampler combine for an unequalled level of efficiency, flexibility, and ease of use.
The 900 Laboratory Analyzer yields productivity gains with analysis times 30 percent faster than its Model 800 predecessor. The instrument enables complete unattended operation with an Autoreagent feature that calculates and applies the appropriate reagent flow rate for any sample without requiring user intervention. Additional productivity enhancements are realized with the optional 900 Autosampler, featuring random access capability and up to 120 sample positions.
Engineered for ease of use and cost-effective operation, the Analyzer needs no external reagents or gas supplies and requires only two hours of preventive maintenance per year. Twelve-month calibration stability frees analysts to perform other critical tasks.
|
|
|
|
|
|
Sievers 500 RL On-Line
GE Analytical Instruments’ new Sievers 500 RL On-Line TOC Analyzer delivers the accuracy, automation, and confidence needed to transition from laboratory to on-line TOC for enhanced operating efficiencies and science-based risk management. Using the proven Sievers laboratory TOC measurement technology, the Sievers 500 RL provides continuous quality assurance for on-line pharmaceutical water release, cleaning validation, and Process Analytical Technology (PAT) quality initiatives.
The Sievers 500 RL On-Line TOC Analyzer uses no reagents and features the revolutionary four-port Super iOS standards introduction device that fully automates system protocols, and transfers critical standards information directly to the Analyzer for secure data management, significantly reducing costs and risks.
The 500 RL Analyzer shares many productivity and ease-of-use features of other Sievers TOC Analyzers, including 12-month calibration stability, a color touch-screen display, USB port, and minimal maintenance (a few hours per year). With a wide operating range of 0.03 ppb to 2,500 ppb, the 500 RL also measures USP conductivity.
|
|
BioTector - TOC ONLINE ANALYZER
TOC, COD, BOD, TC, TIC, VOC - The oxidation process that totally self-cleans
PRODUCT OVERVIEW
• Self-cleaning technology
• Uptime - Typically 99.7%
• Results < 6.5 minutes
• Multi-range
• Single and multi-stream option
• Nitrate & phosphate analysis modules available
General Information
Designed to withstand corrosive environments, the BioTector TOC Analyzer is housed in an FRP enclosure with dual compartments to keep all electronic components separate from the “wet” or analysis section. The BioTector TOC Analyzer has an in-built microcontroller and is operated through a membrane keypad. An SD Falsh Card allows easy software & configuration updates and may be used to download the 5,000 event archive.
|
|
The TN, or Total Nitrogen, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds (for TOC measurement) it also oxidizes bound (organic and inorganic) nitrogen compounds and ammonium compounds into nitrate (NO3-). This nitrate is present as an aqueous ion in the oxidized sample fluid in the BioTector reactor.
When TOC analysis is complete, the sample fluid is brought from the reactor into a measuring cell. Here the spectrophotometer analyzes the wavelengths applicable to nitrates. The result is displayed as Total Nitrogen (TN). A cleaning fluid is then passed through the measuring cell automatically, which ensures that operator cleaning and maintenance is kept to an absolute minimum.
|
|
|
|
|
|
CheckPoint TOC Sensor
The new CheckPoint Total Organic Carbon (TOC) Portable/On-Line Sensor from GE Analytical Instruments is the first and only battery-powered TOC measuring device. CheckPoint can easily be hand carried to any point in a water system for rapid diagnostic sampling and troubleshooting, or used on-line for continuous monitoring. It is designed for microelectronics, pharmaceutical, and power applications.
CheckPoint’s ultra portability, fast analysis time, and versatility enable new problem-solving and diagnostic capabilities at points of use away from power sources. The Sensor typically operates four to five hours using the optional battery, or continuously with AC power. It weighs just 3.6 kg (7.9 lb), and features a 15-second default measurement, adjustable in intervals up to eight hours.
The CheckPoint TOC Sensor has a dynamic range of 0.05 to 1,000 ppb, and can measure TOC in water with up to 1.4 uS/cm conductivity from CO2. CheckPoint also measures conductivity/resistivity and temperature. CheckPoint features an Ethernet (Modbus over TCP/IP) and a USB port for convenient data download. CheckPoint requires no reagents, and is easy to operate and maintain. Calibration is typically stable for six months.
|
|
Sievers 900 Series TOC
The Sievers 900 Series Total Organic Carbon (TOC) Analyzers are designed for organic analysis in ultrapure and municipal quality waters in pharmaceutical, semiconductor, municipal, and power generation applications. The four 900 Analyzers (Laboratory, On-Line, Portable, and the 5310 C for municipal water) offer exceptional ease of use, analytical performance, productivity, and reliability. The random-access 900 Autosampler provides high sample capacity and fast analysis.
The 900 Series TOC Analyzers are easy to set up, operate, and maintain. With minimal training, an operator can analyze samples in less than an hour. Unlike many competitive analyzers that use technologies such as non-dispersive infra-red, the 900 Series Analyzers require no external gasses or reagents, offer 12-month calibration stability, and usually require just a few hours of maintenance annually.
|
|
BioTector TOC TN TP Analyzer
The TP, or Total Phosphorous, Analyzer is an additional analysis tool available from BioTector Analytical Systems. When the BioTector oxidizes organic carbon compounds for TOC measurement, it also reduces phosphorus compounds (with the exception of poly-phosphates) to orthophosphates (PO4-). This phosphate is present as an ion in the oxidized sample fluid in the BioTector reactor.
|
|
* Total Organic Carbon (TOC) Reagent Set, Low Range Test 'N Tube(TM) includes: Acid Digestion Solution Vials, Low Range TOC, Bufer Solution (Sulfate), Micro Funnel, Indicator Ampules, Low Range TOC, TOC Persulfate Powder Pillows
* Method: Direct
* Range: up to 20 mg/L C
* 50/test
|
|
the AQUAPOD the AQUAPOD LIGHT detects and analyzes a broad range of parameter and pollution of drinking water, natural water, industrial wastes, sea water:
NITRATES
DBO
DCO
COT
MY
UV 254 NM
GENERAL ANOMALIES OF WATER
COLORIMETRY
HYDROCARBONS
URBAN REJECTIONS
COMPLEX INDUSTRIAL PRODUCTS
SPECIFIC PRODUCTS
The AQUAPOD LIGHT integrates an analysis UV as well as a detection of fluorescence (in option) making it possible to reach thresholds of seusibilities about the ppm (for the majority of the parameter to the µg/L (hydrocarbons)
Easy to install, without reagents nor calibration, the AQUAPOD Light 2000 ensures you a cost of very low exploitation.
The AQUAPOD LIGHT UV FLUO can accept any type of physico-chemical sensors Modbus RS485, 4 - 20 my...
Moreover, thanks to its exits Modbus, Profibus and Can Open, the AQUAPOD LIGHT can be interfaced quickly towards any system of supervision or communication GPRS or STN
|
|
| ... products without technical information |
| |
|
|