Primary voltage: 72.5 kV - 420 kV
... products that excelled in variety of test and service environments around the globe. Moreover, the Inductive Voltage Transformers-HV has a single coil construction up to 245 kV. It also has a special high voltage coil construction ...
Frequency: 47 Hz - 450 Hz
... Toroidal Transformer Ø28 for Type A-F Earth Leakage Relays Toroidal Transformer Ø28 with integrated secondary cables, for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • operating frequency 25...10kHz ...
FRER
Frequency: 47 Hz - 450 Hz
... Toroidal Transformer Ø24 32x10 for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • operating frequency 25...10kHz -3dB • power-frequency withstanding voltage 3kV 50Hz, 1 min. • installation category CAT. III 600V ...
FRER
Frequency: 47 Hz - 450 Hz
... Toroidal Transformer Ø35 for Type A-F Earth Leakage Relays • thermoplastic material UL 94 • nominal frequency 47...450Hz • operating frequency 25...10kHz -3dB • power-frequency withstanding voltage 3kV 50Hz, 1 min. • installation ...
FRER
Output power kVA: 50 kVA - 2,500 kVA
Primary voltage: 10 kV
Secondary voltage: 0.4 kV
... Oil-immersed Transformer Our oil-immersed transformers are perfect for transforming voltage, commonly from 10kv or 35kv down to 380V or 220V for end-user applications. Suitable for both indoor and outdoor settings, they ...
Output power kVA: 30 kVA - 3,150 kVA
Primary voltage: 12 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural ...
Dowei Electric
Output power kVA: 30 kVA - 1,600 kVA
Primary voltage: 23 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural ...
Dowei Electric
Output power kVA: 50 kVA - 3,150 kVA
Primary voltage: 33 kV
Secondary voltage: 0.4 kV
... • IEC 60076, ANSI/IEEE Std C57.12, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Mineral Oil / Vegetable Oil (FR3), Free PCB • Low loss, Low partial discharge, Low temperature rise • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural ...
Dowei Electric
Output power kVA: 50 kVA - 1,600 kVA
Primary voltage: 12 kV
Frequency: 50 Hz
... 50 ~1600kVA. The product puts the transformer body, high-voltage load switch, fuse and other components together in the transformer tank, and uses the insulating liquid of the transformer as the insulating ...
Output power kVA: 630 kVA - 2,500 kVA
Primary voltage: 10, 35 kV
... The ZGS-ZG series of combined photovoltaic transformers is a series of products developed by Tianan Electric to meet the needs of domestic and foreign users in photovoltaic power generation projects. It is the earliest manufacturer of ...
Output power kVA: 800 kVA - 3,400 kVA
Primary voltage: 35, 10 kV
... The ZGS-ZF series wind power combined transformer is a series of products developed by Tianan Electric to meet the needs of wind power projects of domestic and foreign users. It is the earliest manufacturer of similar products in China ...
... Current transformers connect to Enerclip measurement modules models MSC-N1, MSC-N2, MSC-M4, or MAP4-34RJ using an RJ12 cord MSC-1RJ and a connector MSC-TCO-TRI. Characteristics / Technical Specifications: - Type: Miniature closed ...
Lettel
Primary current: 30 A - 600 A
... The MSC-TCF closed current transformers combine accuracy with ease of integration: - Electrical: current measurement up to 600A, with an accuracy of 0.1%. - Physical: 4 housing sizes depending on the current range measured. ...
Lettel
Primary current: 30 A - 600 A
Secondary current: 1 A - 5 A
... The closed current transformers MSC-TCF combine accuracy with ease of integration: - Electrical: Measure current up to 600A, with an accuracy of 0.1%. - Physical: 4 housing sizes according to the measured current ...
Lettel
Electric power: 0.03 kVA - 25 kVA
Primary current: 0.11 A - 2 A
... Transformers have to be flexible because different situations require different voltages. Murrelektronik's product range offers this flexibility, no matter if it's an isolation transformer, control transformer, ...
Primary current: 40 A - 250 A
Secondary current: 5 A
Frequency: 40 Hz - 60 Hz
... Measurement current transformers for currents from TAM series Modular LV analog current transformers, 2 modules width, from DIN bar for currents ...
AB TRASMISSIONI SRL
Primary voltage: 0 V - 72,500 V
Secondary voltage: 0 V - 350,000 V
... Main advantages Performance and overload Design studied to optimize any installation requirement. Silence High efficiency materials and geometry to reduce noise emission in quiet areas. Eco+POWER Expressly studied to satisfy the most stringent ...
Electric power: 0.024 kVA
Primary voltage: 230 V
Secondary voltage: 24 V
... The CA1A is an economical transformer which reliably delivers either 12Vac or 24Vac and benefits from short circuit protection. Ideal for running a simple keypad and electric strike, this transformer is perfect for small-scale ...
Primary current: 20 A - 5,000 A
Secondary current: 5 A
Frequency: 50 Hz - 60 Hz
... UA-CTR Round Current Transformer Primary current: 20-5000A Secondary current: 5A UA-CT offers a complete range of high quality current transformers suitable for low voltage (LV) applications to meet customer various ...
ADTEK Electronics Co., Ltd
... The products are used in SF6 closed combined electrical apparatus of which no need of demolition in overhaul or test, the center conductor of basin type insulator can realize the disconnect and closure to implement body. The GIS do not ...
Electric power: 25 kVA - 5,000 kVA
Primary voltage: 0 V - 1,000 V
Secondary voltage: 3.3 kV - 36 kV
... Distribution transformers are used to reduce medium voltage from (3.3-36kV) to low voltage (<= 1000 V). ELTAS A.S produces oil type distribution transformers from 25 KVA to 4000 kVA. Distribution transformers ...
Electric power: 0.005 kVA - 0.1 kVA
Primary voltage: 24 kV - 36 kV
Secondary voltage: 100 V - 120 V
... 12-24-36 kV Single Pole Insulated Block Type Design Standard: IEC 60044-2, VDE 0414, ANSI, GOST ...
alce elektrik san ve tic as
Electric power: 0.01 kVA
Secondary voltage: 4, 8, 12 V
... 10VA transformer for continuous service, outputs 4-8-12V 2 DIN Power supply 230V a.c. – 50Hz Outputs 4-8-12V Installation on terminal board IP20 Wall-mounted IP30 Installation on the rear of the switchboard IP40 Dimensions (LxWxH) 35 ...
Primary voltage: 230 V
Secondary voltage: 4 V - 12 V
... Bell transformer ZTR-15-12Designated for general use – e.g. as home bells supply, door locks supplyDESCRIPTION Short-circuit-proof, doubled output terminalsTECHNICAL PARAMETERS Input voltage: AC 230 V Output voltage 4 V, 8 V, ...
ELKO
Secondary voltage: 65 V - 230 V
Primary current: 6.3, 3.15 A
... The SEA Series is a type of transformer in the Mf-net program manufactured by Vostermans Ventilation. The SEA series includes the SEA 3.15 and SEA 6.3. These transformers can be controlled manually, in semi-automatic ...
Output power kVA: 3 kVA - 500 kVA
Secondary voltage: 600 V
... Applications • Machinery equipment • SMT/PCB electronic assembly • Military control System • Automatic testing System • Précision measurement System • Medical equipment • IC Semiconductor • Internet communication System • Data Processing System • ...
Electric power: 0.005 kVA - 0.03 kVA
Primary voltage: 5 V - 3,200 V
... The LV current transformer series manufactured by ENTES, is a set of models that are specially made to transform primary currents by a ratio to its secondary side with 0 degree phase difference. The network's HV side delivers isolation ...
Electric power: 0.025 kVA
Primary voltage: 230, 240, 110, 220 V
Primary current: 108 mA
... possibility of using the transformer for testing electricity meters with closed I-P links i.e. meters with connected current and potential circuits. Broad range of working voltages, high output power and high accuracy ...
Primary voltage: 220 V - 575 V
Secondary voltage: 23 V - 240 V
... The HSZ series of industrial control transformers are designed for applications requiring special mounting and are available in ratings from 1 through 10 kVA. ...
SolaHD
Output power kVA: 25 kVA - 4,000 kVA
Primary voltage: 36 kV
Secondary voltage: 36 kV
... * Cooling Type: ONAN or Customized * Vector Group: YZN, DYN or Customized * Conducting Material: Electrolytic Copper or Electrolytic Aluminum. * Geographical Conditions: Concerned country’s conditions ( Altitude, Humidity, Temperature values ...
... hermetically sealed transformer, the oil does not come into contact with the air and its electrical properties are therefore not compromised, ensuring a long life span of the transformer. For powers exceeding 3150kVA, ...
Electric power: 0 W - 0.675 W
Primary voltage: 20 V - 30 V
Secondary voltage: 32.1 V
... application: Digital two-wire transmitter converts Pt-100, DIN EN 60751 measuring resistors into a 4…20mA current signal. For installation on a standard rail according to EN50022 (DIN, top hat rail). Case:Plastics Case dimensions:B x H x T : 13 ...
Primary voltage: 720 V
Primary current: 1 A - 3,000 A
Frequency: 16.7, 50, 60 Hz
... tasks. The cable provides the insulation against high voltage in this transformer type and also represents the primary winding of the current transformer. The current transformer itself is installed ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group