- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Combined flow meter
Combined flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... generation of onboard fuel consumption measuring systems. Why You Need a FuelTron M.O.V.E Increasing technical complexity combined with more stringent environmental and legislative requirements make modern vehicle development a challenge ...
Process temperature: -5 °C - 90 °C
Process pressure: 10, 16, 40 bar
Precision: 0.2 %
... The OPTIFLUX 2300 is an electromagnetic flowmeter (EMF) for all demanding applications with water and wastewater. The high-end meter is particularly suitable for applications requiring high accuracy and extensive diagnostics. ...
Process temperature: -20 °C - 50 °C
... applications. Area-Velocity Measurement / Open Channel Flow Measurement with No Primary Measuring Device FlowCERT can be combined with a MicroFlow for velocity measurement. Or for area-velocity flow ...
Process temperature: -25 °C - 150 °C
Process pressure: 100 bar
... both temperature and flow rate. The thermodynamic flowmeter needs to be combined with a screw adapter during assembly. The lock is attached to the pipe, and the sensing probe is inserted into the pipe ...
... pressure drop • Can be combined with various measuring / control devices • Nominal widths, lengths and measuring ranges according to customer requirements • Optional: Pneumatic feed for cyclically blow the measuring points • Combined ...
Volumetric flow rate: 0 l/min - 300 l/min
Process temperature: -10 °C - 50 °C
Process pressure: 0.2 bar - 2 bar
... Built upon proven TSI flow sensor technology, the NEW 5000 Series Flow Multi- Meter redefines what a flow meter can do for you. This all-in-one gas mass flow ...
Process temperature: -30 °C - 80 °C
... cycle operation for self-sufficient systems Flow metering at the highest technical level The NivuFlow 750 flow meter is the successor to the well-known OCM Pro CF. Compact dimensions of the flowmeter ...
Process temperature: -30 °C - 70 °C
... Cost-efficient alternative to conventional EMFs/mag
meters. For continuous
flow measurement in slight to heavily polluted media in full pipes
Volumetric flow rate: 0 l/min - 250 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 10, 6, 8, 16 bar
... frequency of the pulse output signal is proportional to the flow. The flow meters feature fast response, low pressure drop and a weatherproof (IP65) enclosure. Features •Make liquid flows ...
Process temperature: 5 °C - 50 °C
Process pressure: 0.01 bar - 10 bar
Repeatibility: 0.5 %
... various functions are combined into one micro fluidic system. The IQ+ FLOW concept offers these functional modules: flow meter, pressure meter, control valve, shut-off ...
Process temperature: -40 °C - 350 °C
... Vortex Flow Meter utilizes the Karman vortex street principle (where alternating vortices are generated as fluid flows through an orifice plate) combined with industrial wireless communication ...
Xi'an Yunyi Instrument Co., Ltd.
Process temperature: -40 °C - 350 °C
... Vortex Flow Meter utilizes the Karman vortex street principle (where alternating vortices are generated as fluid flows through an orifice plate) combined with industrial wireless communication ...
Xi'an Yunyi Instrument Co., Ltd.
Process temperature: -40 °C - 350 °C
... Vortex Flow Meter utilizes the Karman vortex street principle (where alternating vortices are generated as fluid flows through an orifice plate) combined with industrial wireless communication ...
Xi'an Yunyi Instrument Co., Ltd.
Volumetric flow rate: 0.1 l/min - 150 l/min
Process temperature: 0 °C - 90 °C
Precision: 2 %
... In-line Ultrasonic
Flow Sensor DN15-DN50 Support OEM and Customization
Overview
The TG series in-line ultrasonic
flow sensor/
flow
meter is a compact, ...
Volumetric flow rate: 14 l/min
Process temperature: 10 °C - 50 °C
... The hybrid flow-bubble sensors of the series SONOFLOW CO.56 Pro V2.0 and SONOFLOW CO.56 combine accurate flow measurement and reliable air bubble detection in liquid filled medical tubing. They feature ...
Process temperature: 0 °C - 50 °C
... The TQ-Tracer system is especially suitable for sewage applications (purification plant, sewage canals, separate or combined flow systems, aso.) for calibration measurements, measuring and detecting extraneous water, ...
Volumetric flow rate: 0.1 l/min - 30 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... for this magnetic flow meter are diverse: Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media Sensor is intended for ...
Mass Flow ONLINE BV
Volumetric flow rate: 80 l/h - 11,000 l/h
Process temperature: -18 °C - 50 °C
Process pressure: 15,000, 10,000 psi
... Use of an ultrasonic flowmeter is replacing intrusive flow measurement techniques in other designs, introducing a step change in CIMV technology. The ultrasonic flowmeter fires an ultrasonic pulse with ...
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 10 bar
Precision: 0.35, 1 %
... One device. Multiple gases and flows. Maximum flexibility. Multiple gases in one device equals maximum process flexibility and productivity. The GF40 Series elastomer sealed mass flow controllers and meters ...
Brooks Instrument
Process pressure: 0 bar - 15 bar
Precision: 5, 10 %
Repeatibility: 1.5, 0.5 %
... the liquid flow meter to be combined with several interface cables, ensures an optimal match and simplifies the integration of a liquid flow meter into a fluidic system. The ...
Sensirion
Volumetric flow rate: 17,700 l/h
Process temperature: -60 °C - 200 °C
Process pressure: 100 bar
... Coriolis Mass Flow Meter has a maximum mass flow rate of 17,700 kg/hr (650 lb/min) or 2670 bbl/day and nominal size of DN25 (1”). This meter has an accuracy of 0.1% and withstands pressures ...
KEM Küppers Elektromechanik GmbH
... repeatability, and +0.5% standard accuracy. These positive displacement gear meters work in bi-directional flow applications and are unaffected by changing viscosities. The Gear Meters offer multiple ...
Process pressure: 2 MPa
... category by IAEA, combined with the venturi flow measurement technology to measure individual phase flow rate in a three-phase flow. Oil, gas and water fractions are computed in real ...
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one and versatile flow ...
VPInstruments
Volumetric flow rate: 0.4 l/min - 400 l/min
Process temperature: -40 °C - 150 °C
Process pressure: 315 bar
... helical flow meter stands out for its wide measurement range, low impact on the measured fluid, and minimal pressure loss. Only high-quality steels that can withstand corrosive liquids are used in the production of ...
Riels Instruments
... Radar Open Channel Flowmeter Combined Sensor for velocity, level, temperature,instantaneously flow, accumulated flow Powersupply: 9~28VDC Output: RS485 Modbus RTU/4-20mA ...
Volumetric flow rate: 0.1 l/min - 70 l/min
Process temperature: 80 °C
Process pressure: 10, 20 bar
... oval gear flow meter 2950 serves most industrial applications where oil is used as media. It is a dependable flow meter especially designed for lubrication oil flow measurement ...
Kytola Instruments Oy
Precision: 1 %
... LEVIFLOW® single-use flowmeters are designed for non- invasive flow measurements of high purity fluids with flexible tubing. TYPICAL APPLICATIONS •High purity and high precision liquid processes •Sterile non-invasive ...
Process temperature: -10 °C - 60 °C
Precision: 2 %
Repeatibility: 0.2 %
... dataIntroduction F3P adopts the measurement principle of transit time method. Combined with Gentos ultrasonic signal processing technology and unique flow algorithm, fluid flow in the pipeline can ...
Gentos
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group