Primary current: 1,500 mA
Voltage: 1 kV
Diameter / length: 125 mm
... Magnetic track sensor box 4 tracks, 2 optional for fine positioning optional fine positioning tracks with prewarning indication Maintenance-free signal storage and switching in case of power failure Wide angle LED track display ...
Primary current: 0 mA - 250 mA
Voltage: 0 V - 100 V
Diameter / length: 43.3 mm
... Thermoplastic enclosure Non-contact safety switch Does not protrude into the door opening 119,5 mm x 140 mm x 43,3 mm Substitutes door-handle and safety switch, ...
Primary current: 100 A
Voltage: 0.8 kV
Diameter / length: 35 mm
... Max. length of the sensor chain 200 m 2 short-circuit proof PNP safety outputs Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet ...
Primary current: 80 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... switched • 2 safety outputs (semiconductor outputs) • Category 3 / PL e according to EN ISO 13849-1 • Unicode Approach direction Can be adjusted in 90° steps Unicode evaluation Each actuator is highly coded (unicode). The switch ...
EUCHNER GmbH + Co. KG
Primary current: 0.25 A - 8 A
Voltage: 300 V
... monitoring • 2 safety outputs (semiconductor outputs) • Category 4 / PL e according to EN ISO 13849-1 • M12 plug connector 5-pin; pin 5 not used • Unicode Approach direction Can be adjusted in 90° steps Short circuit monitoring The ...
EUCHNER GmbH + Co. KG
Primary current: 0.25 A - 8 A
Voltage: 24 V
... to 20 switches in series • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Category 4 / PL e according to EN ISO 13849-1 • Unicode Approach direction Can be adjusted in 90° steps Short ...
EUCHNER GmbH + Co. KG
Primary current: 3 A
Voltage: 30, 125, 250 V
... Clippard MAS series switches (air to electric switches) use a standard miniature single pole double throw (SPDT) electrical switch which is UL, SEMKO, VDE and CSA certified. The range of switch models ...
Primary current: 5, 3 A
Voltage: 125, 250, 30 V
... has sub-miniature air switches. These one of a kind switches use a standard sub-miniature single pole double throw electrical switch certified UL and CSA. These highly flexible and reliable switches ...
Primary current: 215, 60 mA
Voltage: 24 V
Operating temperature: -25 °C - 60 °C
... Non-contact Safety Switch SS2-OX-3 series - Stainless - Stand-alone Features - PLd per ISO 13849-1 in stand-alone applications - Cross monitoring between two channels - Multiple units can be connected to one safety ...
Line Seiki
Primary current: 215, 60 mA
Voltage: 24 V
Operating temperature: -25 °C - 60 °C
... .3), SIL2: Stand-alone (1 safety switch) - Performance level depends on evaluation of entire system: Combined with a relay unit (1 N.O. + 1 N.C.) Video: Non-contact Safety Door Switches ...
Line Seiki
Primary current: 268, 30 mA
Voltage: 24, 30 V
Diameter / length: 70 mm
... -contact Safety Switch - Stainless - Safety Relay Mandatory - Small type Features - Small type, slim designed, easy to install - Up to PLe per ISO 13849-1 in combination with a safety ...
Line Seiki
Primary current: 2 A
Voltage: 24 V - 48 V
... PL = e • Safety category without an external controller: 3 • Safety Integrity Level: SIL 2 • Cycle before dangerous failure: B10d = 2,000,000 at 2A • Max. activation distance: 10 mm, 2 mm hysteresis ...
COMITRONIC - BTI
Voltage: 24 V
... MASSIMOTTO X5 - Safety Switch for single or double-wing doors Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety ...
COMITRONIC - BTI
Voltage: 12 V - 24 V
... Position control for doors / casings on hazardous machinery Contactless encoded electronic sensor with relay Category 3 total safety management without an external controller 12V version for embedded applications ...
COMITRONIC - BTI
... The SFN series safety non-contact door switches utilize magnetic type detection to monitor opening and closing of doors. The dedicated controller allows multiple connection of up to 30 units. The switches ...
Autonics
Voltage: 10 V - 30 V
... Series 1750 Solid State switches are available for use on most Tom Thumb and PHD products for simple interfacing to many types of electrical controllers. These switches are offered in 10-30 VDC current sinking and current ...
Primary current: max 16.0 A
Voltage: max 250.0 V
... manufactured by Arcoletric, is a safety cut out switch that has a rated current of 16 ampere and a rated voltage of up to 250 V AC. It incorporates an NC contact, shatter switches and lever slope operations. ...
Primary current: 10 mA
Voltage: 2 V - 24 V
Operating temperature: -40 °C - 85 °C
... robust and reliable, ideal for grip or panel mount applications. This 3-position switch provides operator comfort by reducing the movement required to change direction or switch gears. Backlighting provides enhanced visibility; ...
OTTO
... WM-547 Rotary Hand Controls are designed for a variety of off-highway applications. It is infinitely variable between 0° and 90° with applicable uses that include engine RPM, chassis module inputs and hydraulic pump control. The Rotary Hand Control ...
Primary current: 1, 2 A
Voltage: 24, 230 V
Operating temperature: -25 °C - 80 °C
... IDEM’s magnetic, non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO EN14119. They feature magnet and reed technology, providing a high tolerance ...
Idem Safety Switches
Voltage: 4 V
... Window contact for status monitoring of windows and doors. Energy generation by solar power. Battery-free transfer of the opening state of doors and windows. ...
... Contact surfaces – and in particular, door handles – are responsible for spreading vast amounts of bacteria and viruses, some of which can pose a real risk to health. CleanSwitch provides a contact-free, hygienic method of opening doors. It works by ...
Primary current: 0.3 A
Voltage: 24 V
Operating temperature: -10 °C - 55 °C
... 7mm ON / 20mm OFF The MAGNASAFE MS5 are compact, non-contact safety switches designed for use with modern safety relays. Encapsulated into red ABS housings, the MS5 safety switches ...
Mechan Controls
Primary current: 0.2 A
Voltage: 24 V - 250 V
... Compact Housing Wide 10mm sensing LED indication Up to PLe/Cat.4 with ZANDER safety relay High tolerance to misalignment 2 NC/1NO transistor circuits Protection category IP67 ...
Voltage: 19.2 V - 30 V
Operating temperature: -20 °C - 70 °C
... Contactless safety sensor for cascading Coding type: high Reset: locked Diagnostics: detailed ISD (in-series diagnostic) diagnostic system for a complete status image (not safety-relevant) ...
... The non-contact safety switches are designed for mounting on movable protective guards (hoods, hinge switches, doors, etc.). Evaluation takes place, for example, via the SIRIUS 3SK safety relay or the ...
Primary current: 50 mA
Voltage: 9 V - 24 V
Diameter / length: 43 mm