- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flow meter with pulse output
Flow meters with pulse output
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -10 °C - 60 °C
Process pressure: 0 bar - 250 bar
... Electromagnetic Flow meter does not have any moving parts, ideal for wastewater applications or any dirty liquids which is conductive or water based, or for applications where low-pressure drop and low maintenance are ...
Holykell
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
... Clamp On Ultrasonic Flow Meter is a non-contact type clamp-on flowmeter, which can not only measure the flow of large pipe diameter medium, but also can be used for the measurement of strong corrosive, ...
Holykell
Volumetric flow rate: 0.1 m³/h - 381,703.5 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 6 bar - 250 bar
... Electromagnetic flow meters do not have any moving parts and are often chosen because they are less obstructed, cost-effective, bi-directional, and provide highly accurate volume flow measurements. They ...
Holykell
Volumetric flow rate: 0 m³/h - 19.8 m³/h
Process temperature: 0 °C - 90 °C
Precision: 2 %
... wiring recommended
- RS485
- Selectable current outputs: 4–20 mA, 0–20 mA, 0–24 mA
- Pulse output with selectable NPN or PNP modes
- *Current
XY-TEK
Volumetric flow rate: 0 l/min - 150 l/min
Process temperature: 0 °C - 90 °C
Precision: 1 %
... li>
- RS485 communication
- Selectable current outputs: 4–20 mA, 0–20 mA, 0–24 mA
- Selectable pulse outputs: NPN, PNP, PUSH-PULL
- Current
XY-TEK
Volumetric flow rate: 0 l/min - 330 l/min
Process temperature: 0 °C - 60 °C
Precision: 2 %
... In-line Ultrasonic Flow Sensor
Overview
XY-TEK TAD series inline ultrasonic
flow sensors feature a compact design, it can measure and
output ...
XY-TEK
Process temperature: -30 °C - 160 °C
Precision: 1 %
... to +160 °C (depending on transducer)
Flow-velocity range — 0 to ±7 m/s
Turbidity — ≤10000 ppm (with limited bubbles)
Analog
output — One 4-20 mA
output
Pulse
output ...
Process temperature: -40 °C - 80 °C
Precision: 1, 0.5 %
Repeatibility: 0.2 %
... tolerant of small amounts of bubbles or suspended solids
Process temperature: -40 °C - 80 °C
Precision: 0.5 %
Repeatibility: 0.15 %
... range
Repeatability: 0.15%
Linearity: ±0.5%
Pipe size: DN25 to DN5000
Analog
output: 4–20 mA, 750 Ω max load
Pulse
output: 0–9999 Hz, OCT
Relay
output: SPST, 1 Hz max
Communication: ...
Process temperature: -30 °C - 140 °C
Process pressure: 0 bar - 50 bar
... protection
Sensor tube and fitting material: stainless steel 1.4301
Digital
output: RS485 (Modbus RTU)
Analog
output: 4 ... 20 mA (load < 500 Ω)
Pulse
output: 1
pulse ...
BERG Kompressoren GmbH
Volumetric flow rate: 45.54 m³/h - 47,880 m³/h
Process temperature: -30 °C - 110 °C
Process pressure: -1 bar - 50 bar
... by the flowing gas is proportional to mass flow; the temperature difference is used to calculate mass flow.
BERG Kompressoren GmbH
Volumetric flow rate: 290 m³/h - 2,840 m³/h
Process temperature: -30 °C - 80 °C
Process pressure: -1 bar - 16 bar
... mass
flow
meter VA 520 (inline)
Brand
CS-Instruments
Product information
The VA 520 is a thermal
mass (calorimetric)
flow
meter for ...
BERG Kompressoren GmbH
Process temperature: -20 °C - 80 °C
Process pressure: 0 bar - 16 bar
Precision: 1.5, 2.5, 2 %
... accuracy over varying flow conditions.
Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: -25 °C - 180 °C
Process pressure: 40 bar
... The AI.MF Series electromagnetic flow meter from ASIT Italia is the ultimate professional instrument for the precise measurement of conductive liquids. Thanks to the absence of moving parts, it guarantees ...
ASIT ITALIA
Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: -25 °C - 180 °C
Process pressure: 40 bar
... The AI.MF Series electromagnetic flow meter from ASIT Italia is the ultimate professional instrument for the precise measurement of conductive liquids. Thanks to the absence of moving parts, it guarantees ...
ASIT ITALIA
Volumetric flow rate: 0.1 m³/h - 61,072 m³/h
Process temperature: 40 °C - 180 °C
Process pressure: 40 bar
... The AI.MF Series electromagnetic flow meter from ASIT Italia is the ultimate professional instrument for the precise measurement of conductive liquids. Thanks to the absence of moving parts, it guarantees ...
ASIT ITALIA
Volumetric flow rate: 0.0005 m³/h - 2.4 m³/h
Process temperature: -273 °C - 120 °C
Process pressure: 0 bar - 400 bar
... br>
Outputs / Options
- Pulse output
- Analogue output
- Contacts
- Digital / pointer indicator
- Batcher
Principle of Operation
Oval ...
KOBOLD Messring GmbH
Volumetric flow rate: 0.1 l/min - 30 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... analog output 4..20mA PIN 3: GND PIN 4: frequency output PIN 5: do not connect Electrical connection 5-pin-plug M12x1 Applications The fields of application for this magnetic flow meter ...
Mass Flow ONLINE BV
Process temperature: -30 °C - 80 °C
... permanently installed flow meter in distribution stations, in front of individual departments or for billing purposes of individual consumers. Advantages of the VA 520 flow meter: - ...
CS Instruments GmbH & Co. KG
Volumetric flow rate: 0.2 l/min - 16 l/min
Process temperature: -10 °C - 80 °C
Process pressure: 0 bar - 160 bar
... connection plates. Quickly replaceable without long process interruption output signal: Pulse signal The SIKA gearwheel volume sensors are suitable for the detection of volumetric flows with high ...
SIKA
Volumetric flow rate: 2 m³/h - 113,000 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 16 bar
... Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm. Materials Body: EN 1.4404 (SS 316L), PVDF Sensor head: PVDF Electrodes: Hastelloy C, EN 1.4404, Zr, Ti y Tantalum Options High pressure design ...
TECFLUID
Mass flow rate: 60 kg/h - 80,000 kg/h
Process temperature: -40 °C - 180 °C
Process pressure: 40 bar
... VDC
Heinrichs Messtechnik GmbH
Volumetric flow rate: 0.03 m³/h - 1.8 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
... approximate.
Pulses per litre may vary with fluid properties and installation; calibration on the completed installation is recommended. Test protocol reference: RPE at 5 bar (partial
outputs used for nominal measurements).
Flow ...
... included: integrated relay board for PLC interfacing, RS232 link for communication and traceability, 24 V output and configurable pneumatic output for valve and accessory control.
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one and versatile flow ...
VPInstruments
Volumetric flow rate: 0.2 l/min - 100 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 16 bar
... INPUTS AND OUTPUTS Signal Output Type - Digital and Analog Analog output functions - Volumetric flow Frequency output functions ...
Riels Instruments
Volumetric flow rate: 0.085 l/min - 5 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0.5 MPa
... easy-to-use flow-rate control and monitoring system that can be applied to a wide range of fields. This is a type of minute flow sensor OF-WN with display. Flow meter with optional pulse ...
... The FLODEM electromagnetic flow meters are based our decades of experience. They've are highly reliable, easy to operate and very suitable for harsh conditions. ...
SMAAT TECHNIQUES SAS
Process pressure: 16 bar
Precision: 0.5 %
... of electromagnetic flowmeter display part flow meter and wireless communication module. The wireless communication module is equipped with IOT network card, that is SIM card. Its working mode is ...
Kamboda
Volumetric flow rate: 600 m³/h
Process temperature: -10 °C - 85 °C
... electrodes DIN or Tri-clamp process connection 4-20mA current, pulse, HART, Modbus RS485 and bluetooth output options Suitable for food, dairy, beverage and pharmaceutical applications ...
LTH Electronics Ltd
Volumetric flow rate: 0 m³/h - 305,000 m³/h
Process temperature: -20 °C - 150 °C
Process pressure: 0 psi - 9,000 psi
... for the flow rate and flow volume is used for configuration of the flowmeter parameters such as output scaling, total flow reset, damping, etc. Indumart FTM45 Seriesof ...
Process temperature: -20 °C - 120 °C
Precision: 0.2, 0.5, 1 %
... Good repeatability, short-term repeatability up to 0.05%~0.2%, in the trade settlement is the preferred choice of flow meter. 3. Output pulse frequency signal, no zero drift and strong ...
Xian Kacise Optronics Co., Ltd.
Process temperature: -10 °C - 80 °C
Precision: 1 %
... Clamp-on type ultrasonic energy meters for flow and heat consumption measurement. Introduction D116-PT1000 is an upgraded version of D116, adding heat measurement function, so it can detect flow ...
Precision: 0.2 %
... electromagnetic flowmeter for DMA (District Metered Area) • Invest smartly through ‘single box’ DMA solution – combining flow, pressure and data-logging • Have greatest confidence in your billing based on highest accuracy ...
Shanghai Powerbuilder Automation Technology Co. Ltd
Process temperature: -40 °C - 300 °C
Process pressure: 16 bar - 420 bar
... LTD Series General Electron Flowmeter (hereafter call flowmeter), is a precise flowmeter to measure the flow of liquid in the tube. This flowmeter is a patent right product, which is ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group