- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flow meter with pulse output
Flow meters with pulse output
Process temperature: -10 °C - 55 °C
Process pressure: 1, 1.5 MPa
Precision: 1.5 %
... MF5100 series mass flow meters are designed for a large dynamic range (200:1) and high accuracy of 1.5% of reading in flow metering and control applications. With Siargo's proprietary MEMS mass flow ...
SIARGO
Volumetric flow rate: 0 l/min - 800 l/min
Process temperature: -20 °C - 70 °C
Process pressure: 1 MPa
... MF5600 series mass flow meters are designed for general purpose flow metering and control applications where a detachable meter heat is required for some distance data reading. The meters ...
SIARGO
Volumetric flow rate: 0.1 m³/h - 160 m³/h
Process temperature: -20 °C - 65 °C
Process pressure: 0.2 MPa
... The meter is fully operated with battery. It is the 3rd generation of commercial gas meters for city gas applications. The meter is ATEX certified. It has also be used in the industrial burner fuel efficiency ...
SIARGO
... the sensor settings like pipe diameter, gas type or analog output scaling. The sensor offers two different signal output options. It can have a isolated analog and pulse output ...
Process temperature: -30 °C - 70 °C
Process pressure: 0 bar - 10 bar
Precision: 1.5 %
... monitoring your compressed air flow system. Features Thermal mass flow with no additonal compensation required Perfect to measure your compressed air flow ...
Process temperature: -40 °C - 120 °C
Process pressure: 0 MPa - 5 MPa
Repeatibility: 0.25 %
... The S453 Compressed Air Flow Meter is specifically designed for heavy-duty and explosive (Ex) environments, providing precise and reliable thermal mass flow measurements for your industrial ...
Volumetric flow rate: 0.63 ft³/min - 120 ft³/min
... CentriFlow Meter from Eastern Instruments is a Solid Particle Mass Flow Meter that is durable, accurate, maintenance-free, compact, and cost-effective. It is unique and positioned to replace weigh belts, ...
Eastern Instruments
Mass flow rate: 2 lb/h - 200 lb/h
Volumetric flow rate: 1.69 ft³/min - 90 ft³/min
... measuring less expensive products, flow meter cost can be a determining factor in the selection of a flow meter. Unfortunately, extremely accurate flow meters ...
Eastern Instruments
Mass flow rate: 100 lb/h - 1,000,000 lb/h
Volumetric flow rate: 0.1 ft³/min - 156.3 ft³/min
Repeatibility: 0.1 %
... depending on your process. The CentriFlow® Type I Meter, just as all CentriFlow® brand meters, is a mass flow meter designed for measuring bulk solids continuously within a process. ...
Eastern Instruments
Process pressure: 1.6, 2.5, 4 MPa
Precision: 5 %
... Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions of ...
Volumetric flow rate: 0.1 l/min - 30 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... analog output 4..20mA PIN 3: GND PIN 4: frequency output PIN 5: do not connect Electrical connection 5-pin-plug M12x1 Applications The fields of application for this magnetic flow meter ...
Mass Flow ONLINE BV
Process temperature: -40 °C - 150 °C
Precision: 1 %
... Measuring units: volume flow, flow velocity, thermal output Connection: clamp-on for pipe sizes DN10 ... DN6000 Output: 2x 4 - 20 mA, pulse, micro-USB, relay, RS232, ...
KOBOLD Messring GmbH
Process temperature: -30 °C - 80 °C
... permanently installed flow meter in distribution stations, in front of individual departments or for billing purposes of individual consumers. Advantages of the VA 520 flow meter: - ...
CS Instruments GmbH & Co. KG
Volumetric flow rate: 2 m³/h - 113,000 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 16 bar
... Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm. Materials Body: EN 1.4404 (SS 316L), PVDF Sensor head: PVDF Electrodes: Hastelloy C, EN 1.4404, Zr, Ti y Tantalum Options High pressure design ...
TECFLUID
Volumetric flow rate: 0.2 l/min - 16 l/min
Process temperature: -10 °C - 80 °C
Process pressure: 0 bar - 160 bar
... connection plates. Quickly replaceable without long process interruption output signal: Pulse signal The SIKA gearwheel volume sensors are suitable for the detection of volumetric flows with high ...
SIKA
Volumetric flow rate: 0.03 m³/h - 1.8 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
... approximate.
Pulses per litre may vary with fluid properties and installation; calibration on the completed installation is recommended. Test protocol reference: RPE at 5 bar (partial
outputs used for nominal measurements).
Flow ...
... included: integrated relay board for PLC interfacing, RS232 link for communication and traceability, 24 V output and configurable pneumatic output for valve and accessory control.
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one and versatile flow ...
VPInstruments
Volumetric flow rate: 0.2 l/min - 100 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 16 bar
... INPUTS AND OUTPUTS Signal Output Type - Digital and Analog Analog output functions - Volumetric flow Frequency output functions ...
Riels Instruments
Volumetric flow rate: 0.085 l/min - 5 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0.5 MPa
... easy-to-use flow-rate control and monitoring system that can be applied to a wide range of fields. This is a type of minute flow sensor OF-WN with display. Flow meter with optional pulse ...
... The FLODEM electromagnetic flow meters are based our decades of experience. They've are highly reliable, easy to operate and very suitable for harsh conditions. ...
SMAAT TECHNIQUES SAS
Process temperature: -45 °C - 80 °C
Precision: 0.2, 0.5 %
... magnetic flow meter can reach 0.2%. 2. Wide measurement range: electromagnetic flow meter can measure the flow of various fluids, applicable to a variety of industrial ...
Process pressure: 16 bar
Precision: 0.5 %
... of electromagnetic flowmeter display part flow meter and wireless communication module. The wireless communication module is equipped with IOT network card, that is SIM card. Its working mode is ...
Kamboda
Volumetric flow rate: 600 m³/h
Process temperature: -10 °C - 85 °C
... electrodes DIN or Tri-clamp process connection 4-20mA current, pulse, HART, Modbus RS485 and bluetooth output options Suitable for food, dairy, beverage and pharmaceutical applications ...
LTH Electronics Ltd
Volumetric flow rate: 0 m³/h - 305,000 m³/h
Process temperature: -20 °C - 150 °C
Process pressure: 0 psi - 9,000 psi
... for the flow rate and flow volume is used for configuration of the flowmeter parameters such as output scaling, total flow reset, damping, etc. Indumart FTM45 Seriesof ...
Process temperature: -20 °C - 120 °C
Precision: 0.2, 0.5, 1 %
... Good repeatability, short-term repeatability up to 0.05%~0.2%, in the trade settlement is the preferred choice of flow meter. 3. Output pulse frequency signal, no zero drift and strong ...
Xian Kacise Optronics Co., Ltd.
Process temperature: -10 °C - 80 °C
Precision: 1 %
... Clamp-on type ultrasonic energy meters for flow and heat consumption measurement. Introduction D116-PT1000 is an upgraded version of D116, adding heat measurement function, so it can detect flow ...
Precision: 0.2 %
... electromagnetic flowmeter for DMA (District Metered Area) • Invest smartly through ‘single box’ DMA solution – combining flow, pressure and data-logging • Have greatest confidence in your billing based on highest accuracy ...
Shanghai Powerbuilder Automation Technology Co. Ltd
Process temperature: -40 °C - 300 °C
Process pressure: 16 bar - 420 bar
... LTD Series General Electron Flowmeter (hereafter call flowmeter), is a precise flowmeter to measure the flow of liquid in the tube. This flowmeter is a patent right product, which is ...
Volumetric flow rate: 15 l/h - 450 l/h
Process temperature: -20 °C - 80 °C
Process pressure: 0 bar - 30 bar
... measurement accuracy is not affected by bumpy road, display or totalizer Optional, completed set of flow meter could record the instantaneous flow and cumulative flow, total time etc., ...
Soway Tech Limited
Process temperature: 0 °C - 50 °C
Process pressure: 0 Pa - 500,000 Pa
Precision: 3, 2 %
... Ar,O₂,CO₂ etc. ■ Flow range:10SCCM~100SLM Easy operation with display. ・Instant and totalized flow indication ・Upper or lower alarm settintg 1-5VDC or 4-20mA Input/ output signal. Pulse ...
KOFLOC Corp.
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group