- Electricity - Electronics >
- Energy: Production and Distribution >
- Mining equipment transformer
Mining equipment transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 Transformers ...
Tesar Srl
Frequency: 60, 50 Hz
... of cast resin transformers mainly used for energization of rails, metros, highspeed trains, tram- ways, braking energy recovery systems and auxiliary services for sta- tions and signalling. The range of production includes transformers ...
Tesar Srl
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
... Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection interface • ...
Tesar Srl
Electric power: 52,000,000 W
Primary voltage: 0 V - 52,000 V
...
Wherever distribution
transformers have to assure the utmost safety in areas frequented by people, GEAFOL® cast-resin
transformers are the ideal solution. With GEAFOL, the limitations of liquid-filled
transformers ...
Output power kVA: 500, 167 kVA
Primary voltage: 72.5 kV - 550 kV
Secondary voltage: 48, 36, 690 V
... voltage transformer combines the characteristics of a voltage transformer with the capability of a distribution transformer, having an output sufficient for smaller auxiliary loads. Hitachi Energy's gas ...
Hitachi Energy
power transformer76000, 77000, 82000, 83000, 84000, L, N, R, S & T Series
Electric power: 0.375 W - 2.4 W
Primary voltage: 115, 26 V
Secondary voltage: 5 V - 310 V
... Manufactured to MIL-PRF-27, Grade 5, Class S. 90º C Ambient. Regulation is 24% (T Units Have Regulation of 17%) Secondary Voltage Adjusted to Nominal Value at Half Load. Smallest Possible Size. Printed Circuit Thru Hole Construction. Secondary ...
Electric power: 5 W - 150 W
Primary voltage: 115 V
Secondary voltage: 5 V - 115 V
... limited to flight systems, but also in stationary controls, airport equipment, and vehicle mobility systems. This larger class of 400Hz power transformers has an operating temperature range from -55°C to +130°C. Features ...
Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Secondary voltage: 13.2 kV
... AISC 360, AWS D1.1
• High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m
35 kV power
transformer is an electrical
transformer designed for use in power distribution and transmission systems where ...
Dowei Electric
Output power kVA: 630 kVA - 63,000 kVA
Primary voltage: 66,000 V
Secondary voltage: 13,200 V
... AISC 360, AWS D1.1
• High altitude correction per IEC 60076 & IEEE C57.12, ~ 5000m
66 kV power
transformer is a high-voltage
transformer used in electrical transmission and sub-transmission systems. It typically ...
Dowei Electric
Output power kVA: 6,300 kVA - 120,000 kVA
Primary voltage: 110 kV
Secondary voltage: 13.2 kV
... Improved voltage regulation
·Efficient supply to
large load centers
·Suitable for regional transmission networks
110 kV
transformers are among the most common substation
transformers worldwide, ...
Dowei Electric
Output power kVA: 4 kVA
Primary voltage: 440 V
Secondary voltage: 380 V
... Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 100 kVA
Primary voltage: 380 V
Secondary voltage: 385, 222 V
... Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Output power kVA: 500 kVA
Primary voltage: 380 V
Secondary voltage: 380, 660 V
... Power Isolation transformer: Power isolation transformer refers to the input and output winding with electrical isolation transformers, it can avoid accidental hit at the same time transformer ...
Shenzhen Sikes Electric Co., Ltd.
Primary voltage: 10, 20 kV
... Overview The oil immersed power transformer is composed of core, coil, voltage regulating switch, oil tank and other components, and the dielectric material is dielectric oil. Description The oil immersed power transformer ...
Beijing SOJO Electric Co., Ltd
Primary voltage: 20 kV - 24 kV
Secondary voltage: min 0.0 V
Primary current: 5 A - 2,000 A
... LZZBJ9-24 indoor current transformer LZZBJ9-24 is a pillar - type epoxy resin casting insulation fully - enclosed structure. It adopts a ring - shaped iron core coil, and the secondary coil is formed by resin casting. The iron core, ...
Ximai Electric (Wuhan) Co.,Ltd
Output power kVA: 0.63 kVA - 1,000 kVA
Primary voltage: 400 V
Secondary voltage: 400 V
... small peaks of voltage or noise, the TT transformers help improve the quality of the signal that feeds the charges. On the other hand in facilities where there may be several leakage to ground, TT transformers ensure ...
Output power kVA: 250 kVA
Primary voltage: 3,300 V
Secondary voltage: 1,140, 400 V
... Product Overview: The three-phase dry-type transformer for coal mine harvesters powers underground equipment. It's explosion-proof and efficient, ensuring stable ops in hazardous mines and facilitating ...
LUSHAN CHINA
... Transformers with IP-54 degree of protection. Special transformers protected against hostile environment, such as rain, dust and splash water. Single-phase and three-phase series. ...
... The SZ11 three-phase oil-immersed power transformers series are adapted to 10KV, 50HZ transmission and distribution systems, can be used in industrial and mining enterprises and rural power transmission and distribution ...
Electric power: 1 W - 1,000,000 W
Primary voltage: 20 kV - 400 kV
Secondary voltage: 410 V - 90,000 V
... For step-up power transformers, as for wind farm production transformers, we pay particular attention to reducing the transformer’s noise level, as well as ensuring very low load and no-load losses. We ...
Groupe SANERGRID
Electric power: 100 W - 3,150 W
Primary voltage: 15 kV - 20 kV
Secondary voltage: 410 V
... . Trafo ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC standard, to guarantee an optimised life of the dry-type transformer. Description The ...
Groupe SANERGRID
Electric power: 1 W - 100,000 W
Primary voltage: 1,000 V - 36,000 V
Secondary voltage: 100 V - 20,000 V
... ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC normative requirements, in order to guarantee an optimised life of the dry-type transformer. Description The ...
Groupe SANERGRID
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group