- Electricity - Electronics >
- Switch and Relay >
- Surge arrester
Surge arresters
Voltage: 8 V - 255,000 V
Primary current: 100, 200, 50, 2, 1 mA
The compact plug-in indoor use arrestor series protects equipment by absorbing the induced lightning surge that appears in power or signal lines caused by lightning. • Small plug-in structure. • The equipment is built ...
... management systems, surge events can cause disastrous consequences: from damage or destruction of expensive components and machines to breakdown of complete automation systems—not including risks to personnel. Pepperl+Fuchs‘ ...
Voltage: 0 V
Primary current: 40, 50 A
1/4λ surge arrestors are used for protecting antenna equipment and transmission-receiver system against the damages caused by over voltage and induction voltage of lightning. The product is designed according ...
... electronics component to be protected is not affected. Surge arresters are used to weaken residual currents from upstream lightning protection steps and to limit system-induced ...
Endress+Hauser AG
Voltage: 50 V - 200 V
Primary current: 0 mA - 100 mA
... high-performance AR surge arrester absorbs the potential of an inductive lightning surge caused by a lightning discharge to protect electronic instruments. The plug-in arrester ...
Voltage: 0 V - 40 V
... max. Input current must less than FS-A01D’s nominal current. Feature: Compact size Design to suppress the DC power surge to achieve primary protection The attenuation coefficient of frequency meet 30dB ...
Voltage: 230, 440 V
Primary current: 50,000 A
Open circuit voltage: 1.5 kV
Product or component type Surge arrester Device short name PRF1 Device application Distribution Standards EN 61643-11 IEC 61643-11 Product certifications CE Poles description 1P Remote signalling Without Surge ...
Voltage: 48, 24, 230, 120, 12 V
Primary current: 16 A
Compact type III arrester for AC/DC protection acc. to IEC 61643-11:2012 and EN 61643-11. Suitable for protecting end devices. Installed in the vicinity of the equipment to be protected. The arrester ...
Weidmüller
Voltage: 3, 20 kV
... are connected to the terminal block signal, power and earth terminals. Hazardous Area Certifications The TP series surge protectors are certified to numerous worldwide approval standards for hazardous ...
Lightning protection units are available to help protect your AMETEK Level Transmitters and Measurement Systems from unexpected lightning and secondary surges. These high performance ...
Voltage: 10 V - 32 V
... Weighbridges The LC30 Surge Protection Device protects weighing systems and load cell installations from possible malfunction and damage caused by severe over-voltages or high impulse currents on signal cabling. Potentially ...
Voltage: 0 V - 5 V
Primary current: 5,000 A
... various interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge ...
3onedata Co.,Ltd.
Voltage: 0 V - 5 V
Primary current: 5,000 A
... various interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge ...
3onedata Co.,Ltd.
Voltage: 0 V - 5 V
Primary current: 0 A - 5,000 A
... interferences caused by the common ground transmission signal -The excellent lightning protection performance, built-in multi-level surge protection, large surge capacity, ...
3onedata Co.,Ltd.
CeraDiodes are multilayer semiconductive ceramic components for the ESD protection of data, audio and video lines, ICs and I/O ports in electronic devices. New series are designed especially for the ESD protection of LED light sources. ...
TDK Electronics Europe
Lightning protection units are available to help protect your AMETEK Level Transmitters and Measurement Systems from unexpected lightning and secondary surges. These high performance ...
Voltage: 240 V - 415 V
Primary current: 100 A
... interrupt rating Ifi - N-PE - 100 A (260 V) Max. discharge surge current Imax (8/20)μs - L-N / N-PE - 40 kA / 40 kA Voltage protection level UP L-N / N-PE - ≤ 1,5 kV / 1,5 kV Nominal discharge surge ...
Voltage: 0 V - 34 V
Primary current: 1,000 A
Surge protection for single-phase, TN-S / TT ( SPD Class III , Type 3 ). Number of ports - One Nominal voltage UN - 24 V AC (TN-S) Nominal frequency - 50 Hz (60 Hz) Maximum continuous operating voltage UC - ...
Voltage: 2,000 V
Pasternack DC blocks are passive coaxial components that prevent (block) the flow of direct current (DC) frequencies to RF signals. DC blocks from Pasternack are available in 50 Ohm and 75 Ohm designs and can be purchased in inner-only, ...
Pasternack Enterprises, Inc.
Surge Protection Device RJ45-SPD Class EA; suitable for RJ45/11/12 plugs CU-CN Surge Protection Dev RJ45-SPD TH35 Surge Protection Device RJ45-SPD Class EA suitable for RJ45/11/12 ...
Voltage: 150 V - 600 V
Primary current: 100,000, 200,000 A
Class I+II Rated voltage up to 600 Vac Application from 1 to 4 poles Visual and remote contact indicator Benefits Easy installation DIN rail mounting Max nominal discharge phase 100 kA, neutral 200 ...
ENERDOOR
Open circuit voltage: 8 kV
Protects SDI equipment from high voltage surge such as lightning Protects surge up to 8KV Discharging current up to 10KA Reaction speed <1ns Protects HDMI equipment from high voltage surge ...
Primary current: 20,000 A
... designed this lightning protection to save their pumps and after we installed this product, they never had problems with lightning anymore. Since then, every client who sends us a main board for repair, ...
Outdoor In-Line PoE Surge Protector - IP66 Rated, 1 Gbps, Cat5e/6/6a, IEC Compliant, TAA Protects edge network devices, including PoE cameras and LAN access points, from lightning, power surges, ...
TRIPPLITE
Voltage: 180 V
Primary current: 10,000 A
... exceptional in-line broadband DC pass surge protection design incorporating lightning protection circuitry and the EZ-195-X series crimp style connector interface unit. This combination ...
Times Microwave Systems
Voltage: 1 V
Primary current: 2.7 A
Smart Bias-T, 696-2690 MHz, Also known as SBT-6962690-xxx
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining