Inductive voltage transformer JDCF-72.5
instrumentmeasurementimmersed

Inductive voltage transformer - JDCF-72.5 - Dowei Electric - instrument / measurement / immersed
Inductive voltage transformer - JDCF-72.5 - Dowei Electric - instrument / measurement / immersed
Add to favorites
Compare this product

Characteristics

Type
instrument, measurement
Configuration
immersed
Applications
for industrial applications, for industrial use, for electrical networks, protection, for energy meters, substation
Electrical characteristics
single-phase, high-voltage, inductive voltage
Mounting
floor-standing
Norms
IEC, UL, ANSI, TUV
Other characteristics
protection, control, high-accuracy, oil-immersed, multi-winding
Output power kVA

2 kVA
(2.719242 hp)

Primary voltage

72.5 kV

Secondary voltage

Min.: 110 V

Max.: 220 V

Frequency

50 Hz, 60 Hz

Description

• IEC 61869, ANSI/IEEE C57.13, NEMA
• ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA
• Seismic design, ETGI-1.020, IEEE Std 693, NCh2369
• Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1
• High altitude correction per IEC 61869 & IEEE C57, ~ 5000m
• High Quality Paper-Oil Insulation, Mineral oil (No PCB), Hermetically Sealed
• Accuracy classes 0.1, 0.2, 0.5, 1.0, 3.0, 3P, 6P or 0.15, 0.3, 0.6, 1.2 (IEEE)

72.5kV Inductive Voltage Transformer (IVT), also known as a Potential Transformer (PT) or Voltage Transformer (VT), is a high-voltage instrument transformer designed to accurately reduce system voltages up to 72.5 kV to standardized low-voltage values for metering, protection, monitoring, and control. It provides electrical isolation between the high-voltage power network and secondary equipment, ensuring both measurement accuracy and operator safety.

Working Principle

A 72.5kV inductive voltage transformer operates based on the principle of electromagnetic induction. The primary winding is connected across the high-voltage system, inducing a proportional voltage in the secondary winding according to the turns ratio.

Main Components
·High-voltage primary winding
·One or more secondary windings (metering and protection)
·Laminated silicon steel magnetic core
·Oil-paper or SF6-free insulation system (depending on design)
·Porcelain or composite silicone rubber insulator housing
·Primary high-voltage terminal
·Secondary terminal box
·Earthing terminal
·Pressure relief device (oil-filled designs)
·Mounting base

Typical Technical Specifications
·Highest System Voltage: 72.5 kV
·Rated Primary Voltage: 66 kV or 69 kV
·Rated Secondary Voltage: 100 V, 110 V, 100/√3 V, 110/√3 V
·Frequency: 50 Hz / 60 Hz
·Accuracy Class: 0.1, 0.2, 0.5, 3P, 6P
·Rated Burden: 25–200 VA
·Rated Voltage Factor: 1.2 continuous, 1.5 for 30 s or per standard
·Insulation Level: 140/325 kV (Typical)
·Cooling: Natural Oil-Air (ONAN) or Dry Type
·Installation: Outdoor

Applications
A 72.5kV inductive voltage transformer is commonly used in:
·Transmission substations
·Distribution substations
·Utility switching stations
·Industrial substations
·Renewable energy substations
·Wind farms
·Solar power plants
·High-voltage switchyards

Advantages
·High measurement accuracy
·Excellent dielectric insulation
·Reliable long-term operation
·Strong resistance to environmental conditions
·Low maintenance requirements
·High mechanical strength
·Suitable for both metering and protective relaying

Typical Secondary Outputs
Common secondary voltages include:
·100 V
·110 V
·100/√3 V
·110/√3 V

These outputs are used with:
·Revenue energy meters
·Protective relays
·Synchronizing equipment
·SCADA systems
·Power quality analyzers
·Digital fault recorders

Common Standards
A 72.5kV inductive voltage transformer is generally designed and tested in accordance with:
·IEC 61869-3 – Instrument Transformers – Additional requirements for Inductive Voltage Transformers
·IEC 61869-1 – General requirements
·IEEE C57.13 – IEEE Standard Requirements for Instrument Transformers
·IEC 60044-2 (legacy standard, superseded by IEC 61869)

Typical Applications in a 72.5kV Substation
·Busbar voltage measurement
·Transmission line voltage monitoring
·Revenue metering
·Distance and overvoltage protection
·Synchronizing and auto-reclosing
·SCADA and remote monitoring
·Fault recording
·Power quality monitoring

A 72.5kV Inductive Voltage Transformer is an essential component in high-voltage substations, providing a precise, isolated, and scaled representation of system voltage for reliable metering, protection, automation, and control while ensuring safe operation of secondary equipment.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.