Product overviewThe STExS2F is a high output UL, cUL, IECEx and ATEX certified alarm horn sounder featuring a re-entrant flare horn. The robust 316L stainless steel enclosure is approved for Zone 1, 2, 21 & 22 explosion proof signalling applications. Featuring 64 alarm tone sounds, each of the available 4 stages/channels can be remotely triggered. Class D amplification provides a high sound output with a choice of two power modes. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard, with optional diagnostic module for Route 1H SIL2 compliance.
Upgraded Product- New D Class amplifier technology
- Reduced in-rush
- A4 316 stainless steel bracket as standard
- Tropicalised electronics
- New stage activation and line monitoring capability
Features- Maximum sound pressure level output of 123dB(A)
- Choice of 64 alarm tone frequencies
- 4 remotely selectable alarm stages/channels
- Positive or negative line stage/channel switching
- Automatic synchronisation on multi-sounder system
- Ratchet adjustable 316 stainless steel bracket
- Triple cable entries
- Available with custom tone configurations and frequencies
- Robust corrosion proof 316L stainless steel enclosure
Tone capability64 selectable tones (UKOOA / PFEER compliant). Stage 1 tones can be assigned to other stages; country specific or custom tone configurations and alarm frequencies are available.
Caractéristiques / spécifications techniques- Maximum output: High power level: 123dB(A) @ 1 m ±3dB [114dB(A) @ 10ft/3m ±3dB]; Default power level: 118dB(A) @ 1 m ±3dB [109dB(A) @ 10ft/3m ±3dB]
- Nominal output: High power level: 120dB(A) @ 1m ±3dB [111dB(A) @ 10ft/3m ±3dB]; Default power level: 115dB(A) @ 1m ±3dB [106dB(A) @ 10ft/3m ±3dB]
- No. of tones: 64 (UKOOA / PFEER compliant)
- No. of stages: 4
- Volume control: Full range
- Effective range: 200m / 656ft @ 1kHz
- Voltages DC: 24Vdc (11.5-54Vdc)
- Voltages AC: 230Vac (100-240Vac)
- In-rush: 815mA within 4ms @ 24Vdc
- Stage switching: DC units: positive or negative; AC units: common supply line
- Safety Integrity Level: Product version A: SIL1 and SIL2 Route 2H; Product version S: SIL2 Route 1H with diagnostics SFF: >99% (see install manual for reliability & functional safety data)
- Ingress protection: EN60529: IP66/67
- Enclosure material: 316L Stainless Steel
- Enclosure colour: Red
- Enclosure finish: Chromate & powder coated finish; ISO 12944-6 CX, C5VH & C5H
- Cable entries: 3 x M20x1.5mm; stopping plugs included
- Stopping plugs: Stainless Steel
- Terminals: 0.5 – 2.5mm² (20-14 AWG); pluggable & duplicated terminals
- Line monitoring: Diode polarized for use in supervised circuits; blocking diode for reverse polarity monitoring; EOL min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
- Ground / Earth stud: M5
- Enclosure volume: <2 litres
- Installation temperature: -50° to +70°C (-58°F to +158°F)
- Storage temperature: -50° to +70°C (-58°F to +158°F)
- Relative humidity: 99%
- MTBF DC: 93.92 years / 822,706 hours – MIL 217
- MTBF AC: 46.66 years / 408,508 hours – MIL 217
- Weight: 6.25kg / 13.75lbs
- Current consumption examples: 12Vdc (11.5-54Vdc) Default power current 289mA, High power current 356mA; 24Vdc default 324mA, high power 740mA, in-rush 815mA <4ms; 115Vac/230Vac nominal values given in wiring schematics and tables
- Part codes / options summary: Product type STExS2; Horn type F (Flare re-entrant horn); Voltages DC024 / AC230; Cable entries options A–G (3 x M20x1.5mm or NPT/M25 adaptors); Bracket material A4 316 Stainless Steel; Product versions: A, S, T; Product options include standard, custom tone software, custom configuration, stage control configs
- Approvals: UL/cUL/ULC (E230764), IECEx, ATEX, INMETRO, DNV, Ex EAC, PESO CCOE, UKCA and SIL1 & SIL2 compliant to IEC61508 (2010)