Current repeater X1-IS-DI-02-S
SIL 2for hazardous areas

Current repeater - X1-IS-DI-02-S - GM International S.p.A. - SIL 2 / for hazardous areas
Current repeater - X1-IS-DI-02-S - GM International S.p.A. - SIL 2 / for hazardous areas
Current repeater - X1-IS-DI-02-S - GM International S.p.A. - SIL 2 / for hazardous areas - image - 2
Add to favorites
Compare this product

Characteristics

Options
current, for hazardous areas, SIL 2

Description

The Switch/Proximity Detector Repeater X1-IS-DI-02 is a module suitable for applications requiring SIL 2 level in safety related systems for high risk industries. The unit can be configured for switches or proximity detectors, located in Hazardous Area, and repeats the input state to an open-collector transistor in Safe Area. The selectable fault detection circuit is available for proximity sensors or switches equipped with end-of-line resistors. When selected, the fault drives the common line and may also force the output open, if required. Input to output function can be inverted. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.SIL 2 / SC 3Input from Zone 0 / Division 1Installation in Zone 2 / Division 2Loop disconnection to ease maintenance operationsHigh frequency transistor outputField open and short circuit detection (software programmable)Inverted output available (software programmable)Three port isolation, Input/Output/SupplyTechnical Specifications:Power Dissipation: 0.4 W @ 24 Vdc with short circuit input and 100 mA output current, typical.System Supply Voltage: 24 Vdc nom (18 to 30 Vdc).Current Consumption: 13 mA @ 24 Vdc with short circuit input and closed output, typical.System Output Type: Voltage free SPST optocoupled open-collector transistor. Programmable via software.Max Output Voltage: 35 Vdc.Max Output Current: 50 mA.Max Voltage Drop: 1.5 V @ 50 mA.Leakage Current: ≤ 50 μA @ 35 Vdc.Response Time: ≤ 1 ms.Frequency Response: 500 Hz maximum.Field Input Type: Voltage source according to NAMUR standard.Input Equivalent Source: 8 V/1 kΩ typical (8 V no load, 8 mA short).Input Switching Current Levels: ON ≥ 2.1 mA, OFF ≤ 1.2 mA.No Fault: input current ≥ 0.35 mA and input resistance ≥ 360 Ω.Open Fault: input current ≤ 0.05 mA.Short Fault: input resistance ≤ 100 Ω.Fault Type: Field sensor fault available on the common fault line when input diagnostics is active.Isolation Test Voltage: Field In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.Operating Temperature: –40 to +70 °C.Storage Temperature: –45 to +80 °C.Equipment: Associated apparatus and non-sparking electrical equipment.Safety Parameters: Uo = 10.5 V, Io = 11 mA, Po = 29 mW at terminals A-Z Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.Mounting: On custom Termination Board.Weight: about 55 g.Dimensions: Width 10 mm, Depth 80 mm, Height 120 mm.

Catalogs

No catalogs are available for this product.

See all of GM International S.p.A.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.