Application ScopeSuitable for power connection cables for household appliances, small power tools, electrical instruments, electronic equipment, power equipment, lighting and other mobile/flexible applications with AC rated voltage U0/U 450/750V or less.
Notes- Material: Conductor is high-purity oxygen-free copper wire; insulation is environmentally friendly PVC.
- Standards: GB/T5023.3-2008.
- Rated voltage: U0/U 450/750V.
Operating Characteristics- Long-term operating temperature: ≤70℃.
- Cable laying ambient temperature: ≥0℃.
- Bending radius: For flexible cables: D < 25 mm → ≥4D; D ≥ 25 mm → ≥6D.
- Structure: Conductor + Insulation (two-layer).
DownloadPDF of product category specifications available (see product page).
Parameter TableSpecification (mm²) | Conductor structure (n/mm) | Insulation thickness (mm) | Outer diameter lower limit (mm) | Outer diameter upper limit (mm) | Conductor resistance at 20℃ (Max, Ω/km) | Insulation resistance at 70℃ (Min, MΩ·km) | Current-carrying capacity (A)
0.75 | 24/0.20 | 0.6 | 2.2 | 2.7 | 26 | 0.011 | 7
1 | 32/0.20 | 0.6 | 2.4 | 2.8 | 19.5 | 0.01 | 11
1.5 | 48/0.20 | 0.7 | 2.8 | 3.4 | 13.3 | 0.01 | 17
2.5 | 49/0.25 | 0.8 | 3.4 | 4.1 | 7.98 | 0.009 | 26
4 | 81/0.25 | 0.8 | 3.9 | 4.8 | 4.95 | 0.007 | 35
6 | 84/0.30 | 0.8 | 4.4 | 5.3 | 3.3 | 0.006 | 46
10 | 84/0.40 | 1.0 | 5.7 | 6.8 | 1.91 | 0.0056 | 63
16 | 126/0.40 | 1.0 | 6.7 | 8.1 | 1.21 | 0.0046 | 85
25 | 196/0.40 | 1.2 | 8.4 | 10.2 | 0.78 | 0.0044 | 112
35 | 276/0.40 | 1.2 | 9.7 | 11.7 | 0.554 | 0.0038 | 138
50 | 396/0.40 | 1.4 | 11.5 | 13.9 | 0.386 | 0.0037 | 168
70 | 360/0.50 | 1.4 | 13.2 | 16.0 | 0.268 | 0.0032 | 213
Technical specifications- Conductor: High-purity oxygen-free copper wire with strand constructions varying by section.
- Insulation: Environmentally friendly PVC; insulation thickness varies by size (see table: 0.6–1.4 mm).
- Standards compliance: GB/T5023.3-2008.
- Rated voltage: U0/U 450/750V.
- Temperature rating: Long-term ≤70℃; laying ambient temperature ≥0℃.
- Bending radius: For flexible cables: D < 25 mm → ≥4D; D ≥ 25 mm → ≥6D.
- Structure: Conductor + Insulation (two-layer).
- Electrical data: Conductor resistance, insulation resistance and reference current-carrying capacities provided in the parameter table.