Application ScopeControl signal cables for connecting robot control systems (including arc welding, spot welding, assembly, painting, material handling, underwater exploration, engraving, palletising and other robot types). Suitable for continuous flexing in cable drag chains and environments with electromagnetic interference from motors and equipment.
Product Features- Flexible, bendable cable body with abrasion- and cut-resistant outer sheath
- Flame retardancy: IEC 60332-1-2; Oil resistance: EN 60811-404
- Maximum travel speed: ≤ 3 m/s
- Bending radius: travel < 10 m → 4×D; travel ≥ 10 m → 7.5×D (D = cable outer diameter)
- Designed for continuous drag-chain operation with service life > 20 million cycles
Product Structure- Conductor: ultra-fine, multi-strand, finely twisted bare copper (with tensile core), compliant with IEC 60228
- Insulation: Category 6 TPE core insulation
- Outer sheath: PUR, colour grey (RAL 7001)
- Stranding: < 8 cores — bundled; ≥ 8 cores — grouped around reinforcement core
Technical Specifications- Conductor marking: black conductors with white numeric marking per DIN VDE 0293
- Conductor resistance: IEC 60228 Class 6
- Protective earth notation: G = includes yellow-green protective earth conductor; X = without yellow-green conductor
- Rated voltage: 300/300 V
Parameter TableSpecification (mm²) | Cable outer diameter (mm) | Conductor outer diameter (mm) | Conductor Resistance at 20°C (Max, Ω/km) | Insulation thickness (mm) | Sheath thickness (mm) | Rated voltage (V)
10×0.2 | 9.1±0.2 | 1.3 | 92.3 | 0.4 | 1.3 | 300/300V
10×0.3 | 9.8±0.2 | 1.5 | 69.2 | 0.5 | 1.3 | 300/300V
10×0.5 | 11.0±0.2 | 1.8 | 39.0 | 0.5 | 1.4 | 300/300V
Characteristics / Technical specifications- Conductor: ultra-fine multi-strand bare copper with tensile core, IEC 60228
- Insulation material: TPE (Category 6)
- Sheath material: PUR, grey (RAL 7001)
- Operational travel speed ≤ 3 m/s; bending radius guidance 4×D (<10 m) or 7.5×D (≥10 m)
- Intended for continuous drag-chain use—high abrasion and bending resistance (service life > 20 million cycles)
- Standards: IEC 60332-1-2 (flame retardancy); EN 60811-404 (oil resistance); DIN VDE 0293 (conductor marking); IEC 60228 Class 6 (conductor resistance)
- Rated voltage: 300/300 V