Application ScopePrimarily used in electrical control, conveying and transmission systems of industrial automation equipment. Particularly suited to mechanical applications with repeated bending and torsional movements, e.g. robotics and energy/drag chains. Designed for industrial environments requiring high mechanical performance and chemical resistance.
Product Features- Flexible, bendable, abrasion-resistant outer surface; cut-resistant
- Flame retardant per IEC 60332-1-2; oil resistance per EN 60811-404
- Travel speed: up to 3 m/s
- Bending radius: for travel < 10 m → 4×D; for travel ≥ 10 m → 7.5×D (D = cable outer diameter)
- Service life: >20 million drag-chain cycles
Product Structure- Conductor: ultra-fine multi-strand tinned bare copper (tensile core), compliant with IEC 60228
- Insulation: Category 6 TPE core insulation
- Outer sheath: PUR, grey (RAL 7001)
- Stranding: <8 cores — bundled stranding; ≥8 cores — grouped stranding around reinforcement core
Technical SpecificationsConductor marking: black conductors with white numerical marking per DIN VDE 0293
Conductor resistance: IEC 60228 Class 6 compliant
Protective earth conductor: G = includes yellow-green protective earth conductor; X = no yellow-green protective earth conductor included
Parameter TableSpecification (mm²) | Cable outer diameter (mm) | Conductor outer diameter (mm) | Conductor Resistance at 20°C (Max, Ω/km) | Insulation thickness (mm) | Sheath thickness (mm) | Rated voltage (V)
2*0.2 | 5±0.2 | 1.3 | 92.3 | 0.4 | 1.0 | 300/300V
2*0.3 | 5.4±0.2 | 1.5 | 69.2 | 0.5 | 1.1 | 300/300V
2*0.5 | 5.8±0.2 | 1.8 | 39 | 0.5 | 1.1 | 300/300V
2*0.75 | 6.8±0.2 | 2.2 | 26 | 0.6 | 1.1 | 300/500V
2*1.0 | 7.4±0.2 | 2.4 | 19.5 | 0.6 | 1.2 | 300/500V
2*1.5 | 8.2±0.2 | 2.8 | 13.3 | 0.7 | 1.2 | 300/500V
2*2.5 | 9.8±0.2 | 3.4 | 7.98 | 0.8 | 1.3 | 300/500V
2*6.0 | 14.5±0.2 | 5.2 | 3.65 | 0.9 | 1.8 | 300/500V
Characteristics / Technical details- Materials: PUR outer sheath (grey RAL 7001); TPE core insulation
- Bending life: >20 million chain-drag cycles
- Bending radius rules: <10 m travel → 4×D; ≥10 m travel → 7.5×D
- Maximum speed: up to 3 m/s
- Standards: IEC 60332-1-2 (flame retardant); EN 60811-404 (oil resistance); IEC 60228 (conductor)
- Available conductor sizes: 2×0.2 to 2×6.0 mm² (see parameter table)
- Rated voltages: 300/300 V and up to 300/500 V depending on size