Climate chamber DT-C series
thermostatictemperaturehumidity

Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 2
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 3
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 4
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 5
Climate chamber - DT-C series - AI SI LI (China) Test Equipment Co., Ltd - thermostatic / temperature / humidity - image - 6
Add to favorites
Compare this product

Characteristics

Type
climatic, thermostatic
Controlled parameter
temperature, humidity
Test type
dust, sand
Product applications
for vehicles, electronic equipment, for auto lamp
Application domain
international standards-compliant, laboratory
Configuration
floor-standing
Options and accessories
remote-controlled, with temperature and climatic control
Temperature

Min.: 10 °C
(50 °F)

Max.: 40 °C
(104 °F)

Interior length

1,000 mm
(39.37 in)

Interior height

1,000 mm
(39.37 in)

Interior depth

1,000 mm
(39.37 in)

External length

1,650 mm
(65 in)

External height

1,850 mm
(72.83 in)

External depth

1,450 mm
(57.09 in)

Description

Description
The EN 60529 sand and dust resistance test chamber (DT-C series) generates controlled sand/dust atmospheres to evaluate component and enclosure resistance to particle penetration, abrasion and performance under dry sand/dust conditions. It supports both free-fall dust and pressure-spray (cyclone) modes to reproduce field-relevant contamination patterns.

Application
Designed for industrial R&D and quality control, the chamber is suitable for testing automotive parts, lighting, meters, seat mechanisms, electrical appliance boots, connectors and other components requiring compliance with JIS/ISO/IEC/IP ingress standards.

Technical parameters
Model: DT-C1 | DT-C2
Remark: C = cyclone dust mode
Sand/dust concentration: C1 = 5000 mg/m³ @ 5 m/s | C2 = 100 mg/m³ @ 10 m/s
Internal dimension (WxHxD): 1000 × 1000 × 1000 mm
External dimension (WxHxD): 1650 × 1850 × 1450 mm
Temperature range: RT (25°C ± 15°C) or laboratory temperature
Humidity range: 35–90% R.H. or laboratory humidity
Talcum powder dosage: 2–4 kg/m²
Metal mesh diameter: 50 μm; wire spacing: 75 μm
Powder spray & dust fall modes: 1) Free-fall: centrifugal fan lifts dust to ~1/5 roof height then falls; 2) Pressure-spray: bottom pressure-spray with multi-step adjustment
Test standards: compliant with JIS, ISO, IEC60529, DIN40050, GB2423
Power: AC 220V (±10%), single-phase, 50/60 Hz

Features
  • Adjustable high-performance dust spray system with independent control of floating-dust modes.
  • Integrated vibration unit to maintain consistent spray density.
  • Precision dust concentration collection to minimise measurement deviation.
  • Designed to meet DIN, IEC, GB, ISO and JIS standards.
  • Control system supports computer connection and remote monitoring.
  • Easy access and layout for routine cleaning and maintenance.
  • Synchronous resonance function to ensure uniform dust concentration distribution.

Pictures for reference
Reference images show machine layout, test setups and typical fixtures used for component testing.

Warranty
One-year free warranty for the complete machine; lifetime maintenance support available.

After-sale service
Supplier commits to respond within 8 hours after receiving service requests by phone or email.

Service
OEM manufacturing, custom design and buyer-label services available.

Specifications / technical characteristics
  • Models: DT-C1, DT-C2
  • Concentration options: C1 = 5000 mg/m³ @ 5 m/s; C2 = 100 mg/m³ @ 10 m/s
  • Internal dimension: 1000 × 1000 × 1000 mm
  • External dimension: 1650 × 1850 × 1450 mm
  • Temperature range: RT (25°C ± 15°C) or lab temperature
  • Humidity range: 35–90% R.H. or lab humidity
  • Talcum powder dosage: 2–4 kg/m²
  • Metal mesh standard diameter: 50 μm; spacing between wires: 75 μm
  • Powder spray modes: free-fall and pressure-spray (adjustable)
  • Standards: JIS, ISO, IEC60529, DIN40050, GB2423
  • Power supply: AC 220V (±10%), single-phase, 50/60 Hz
  • Control: computer-connectable for monitoring and data logging
  • Warranty: 1 year free; lifelong maintenance
  • Certifications: third-party calibration report (China), CE