Vapor Pressure Process Analyzer - MINIVAP Online
MINIVAP ON-LINE is a process monitoring analyzer for the determination of the vapor pressure of gasoline, crude oil, LPG and NPG.
Also, the vapor-liquid ratio (LVR) of gasoline can be measured.
The measuring principle is identical to the worldwide used laboratory instruments MINVAP VPS and LPG and therefore MINIVAP ON-LINE produces equivalent results.
Up to 2 different sample streams can be connected to one single analyzer. It is the only available process vapor pressure tester that fully complies to the industry relevant ASTM standards for gasoline (ASTM D6378), crude oil (D6377) and LPG (D6897).
On-line Compliance Monitoring for Vapor Pressure of Gasoline, LPG and Crude Oil and Vapor/Liquid-Ratio Temperature of Gasoline (V/L=20)
VAPOR PRESSURE TESTER COMPLIES WITH:
*ASTM D6378 - Vapor Pressure of Gasoline (VPx)
*ASTM D6377 - Vapor Pressure of Crude Oil
*ASTM D6897 - Latest standard for Vapor Pressure of LPG
EXCELLENT CORRELATION TO:
*ASTM D5188 - V/L-Ratio: T (V/L = 20)
*ASTM D1267 - Vapor Pressure of LPG
*ASTM D323, D4953, D5191 (Correlation Formulas)
*EN 13016-1 / IP 394
OTHER FEATURES:
*One Single Instrument for up to 2 Sample Streams
*Multiple Point Measurements at Different Nominal Pressures
*Automatic Calibration & Offset Correction
*Temperature Controlled Sample Conditioning System
*7 Minutes Cycle Time
*Explosion Proof-Class I
*Fast & Easy Maintenance
*V/L-ratio: 4/1 (Gasoline & Crude Oil)
*V/L-ratio: 1/2 & 2/3 (LPG & NPG)
*V/L-ratio: 20/1 (LVR-temperature)
|
|
AUTOMATIC FILM APPLICATOR No.542-AB
This instrument is the coating machine for Appricator and Bar coater.
|
|
|
Capillary electrophoresis (CE) with its high efficiency, rapid analysis time and use of minimal sample and reagent volumens, covers a broad range of applications in a wide variety of industries. Agilent Technologies pioneered the development of this technique with the Agilent 3D Capillary Electrophoresis system. Ever since the system was introduced in 1993 Agilent Technologies is a leader in the CE technology world and is sustaining its innovations. In particular the high sensitivity detection cell and the fully integrated solutions for CE/MS open up a diverse application area.
|
|
|
Provides a safe and simple way to measure petroleum products tendency to thermally degrade and form coke under high temperature pyrolyzing conditions. Free up skilled expensive lab personnel by allowing operators to weigh the initial and final samples then start the test. It is that easy! The MCRT-160 automatically executes the factory programmed ASTM D 4530 test program. Plus, it can even be programmed to automate your own specialized time-temperature test profiles.
|
|
The AshAlyzer LB 421 is a state-of-the-art coal analyzing measuring system based on the Radiation Transmission Technology. This product combines optimum precision and the highest degree of reliability with strong customer orientation. Due to its modular structure, the AshAlyzer LB 421 can be adapted to suit your individual needs.
Applications in coal industry :
- Monitoring coal quality during train loading or delivery
- Controling coal preparation and blending methods
- Monitoring coal production to get early recognitions of trends
in the coal composition
|
|
|
|
|
|
DEA 230 Epsilon
There are three different systems in the 230 Epsilon series of Dielectric Cure Monitors: the high-performance, 2-channel DEA 230/2 with the broadest measurement and frequency range, particularly for product development and process optimization, the single-channel DEA 230/1, and the 10-channel DEA 230/10, also suitable for applications in manufacturing.
For the investigation of the curing behavior of thermosetting resin systems, composite materials, adhesives and paints, dielectric analysis (DEA) has stood the test of time because it can be employed not only on a laboratory scale, but also in process. Versatile sensors for almost every application are available for measurement of the ion viscosity.
The different models of the DEA 230 Epsilon can be connected to the dynamic mechanical analyzer DMA 242 C for simultaneous DMA-DEA analyses. The combination of these complimentary methods provides additional information for complete characterization of the crosslinking behavior of the reactive polymers.
|
|
The various stages of drying and curing that occur in films are easy to detect but difficult to define in terms of chemical and physical principles. In order to evaluate them satisfactory, it is necessary to use instrumentation under controlled conditions.
BYK-Gardner offers a versatile drying time recorder to help quantify the various stages of film curing and drying, deliver reproducible results, and guarantee highest efficiency.
|
|
|
|
|
|
The DynaPro NanoStar from Wyatt Technology is a brand new, Dynamic Light Scattering (DLS) instrument that is used for the analysis of protein solutions, promiscuous inhibitors, buffers or other products in solution. The NanoStar is empowered with more than twice the signal-to-noise of its predecessor, and has replaced virtually every major component in order to make it a full-fledged member of Wyatt's family of instruments.
Since its inception in the early 1990's, the Protein Solutions DynaPro DLS instrument began appearing in protein crystallization and characterization labs throughout the world - the first DLS (Dynamic Light Scattering) technology meeting the scientific community's need to measure small volumes of proteins under very dilute solution conditions. The DynaPro quickly earned acceptance on a global basis, and has since become an indispensable tool for biomolecular sizing and characterization.
The new instrument has a TCP/IP interface, so it can be put on a laboratory network instantly and operated from anywhere with an Internet connection. The NanoStar comes with a double density correlator installed. The DD correlator has 512 bins from 100nsec to 1 hour. Instead of having 16 bins in the first stage and 8 in each subsequent stage, it has 32 in the first stage and 16 in the higher stages.
In order to insure that the NanoStar never goes out of range, it comes equipped with automatic attentution over five orders of magnitude. Its air-launched laser, coupled with proprietary optics for higher sensitivity, make single mode optical fiber technology obsolete. Refinements have been made to the temperature control systems for improved response time; and the ability to couple with Wyatt's on-line multi-angle light scattering systems for enhanced resolution are also standard parts of the package.
Finally, a dedicated Static Light Scattering detector has been added to the NanoStar so that it can measure not only hydrodynamic radii, but absolute molecular weights as well.
|
|
|
|
|
|
EVM-7 Environmental Monitor
Particulate and air quality monitoring in one instrument.
Quest Technologies EVM-7 offers the unique capability to simultaneously measure particulates (mass concentration), volatile organic compounds (VOCs), toxic gas, carbon dioxide (CO2), relative humidity, temperature and air velocity (with optional accessory).
Key Features
--------------------------------------------------------------------------------
Simultaneously Measure Particulate and Gas Concentrations
Reduces the need for multiple instruments
Lowers the cost of ownership.
Dial-in Rotary Impactor
Twist and click selection of particulate settings:
PM2.5, PM4, PM10 or TSP*
90° Light Scattering Photometer
Mass concentration engine offers real-time measurement of particulates.
Built in Sampling Pump for Gravimetric Analysis
Allows user to insert a 37 mm filter cassette to capture particulates for laboratory testing.
*Within the instrument’s measurement range.
Applications Include
--------------------------------------------------------------------------------
Work Site Monitoring
Industrial Fence Line Monitoring
Industrial Hygiene Surveys
Remediation Sampling
Military Site Evaluation
IAQ Walk Through & Stationary Studies
Internal Vehicle Sampling (aircraft, trains)
Air Quality Assessment
Construction/Mining Site Monitoring
VOC Screening and Monitoring
Time-History Assessment
Regulatory Compliance
For pricing and availability information regarding purchase, service or calibration, please email Customer Service.
|
|
The TITAN gas analysis system that represents a "total solution" to your next project could include:
- A modular industrial spectrometer designed for versatile external sample interfacing
- A selection of optimized gas cells
- Powerful AutoQuant Pro software
- High quality spectral reference libraries
- Assistance with method development, (including EPA and SEMATEC protocols)
|
|
|
Kanomax Cleanroom Monitoring System (CRMS) provides an automated means to monitor and gather airborne particle count and other parameters level in controlled environments. CRMS allows users to perform a variety of functions from PC including the alteration of alarms information and viewing of particle count concentrations.
|
|
Film Applicator COATMASTER 509 MC I
Intended for the application of even paint films of defined thickness on glass panes, test charts or foils. Control box on flexible lead with foil keyboard and LCD to control the working movement, to determine the operation mode and to select the working parameters. The version 509 MC III is a combined Film Applicator and Drying Time Recorder.
|
|
Film Applicator and Drying Time Recorder COATMASTER 509 MC III
Besides its function as a film applicator, this combined instrument also offers the possibility to evaluate the degree of dryness of 7 identical or different paint specimens simultaneously. Most versatile instrument due to a variety of accessories. Mobile control box with LCD to select the working movement, the operation mode as well as the working parameters.
|
|
LACHAT's QUIKCHEM 8500 Flow Injection Analysis System features high sample throughput and simple but rapid method changeover. The QUIKCHEM 8500 maximises productivity in determining ionic species in a variety of sample
types, from sub-ppb to percent concentrations. With over 400 methods for environmental, agronomic and industrial applications, including ISO accepted methods, the QUIKCHEM 8500 will satisfy all your analytical requirements.
|
|
The Diode Array 7200 is a modern NIR instrument which makes analysis more rapid, simple and accurate than ever before. It's the second generation diode array instrument from Perten Instruments, with many improvements based on our experience.
You will be able to analyze your raw materials, process intermediaries and your finished products in the same instrument, without sample preparation and without hardware changes.
Launched in 2003 the DA 7200 has quickly become established in the grain, feed and food industries with numerous installations all over the world. Please use the links below to find out why the DA 7200 is so popular.
|
|
HFM 436 Lambda - Heat flow meter
With the HFM 436 Lambda, samples measuring 30 cm x 30 cm or 60 cm x 60 cm and of variable thicknesses ranging from a few millimeters to 10 (20) cm are tested between two heat flux sensors in fixed or adjustable temperature gradients. After a few minutes for the system to reach equilibrium, the built-in PC or external computer determines the thermal conductivity and thermal resistance of the sample.
Automatic plate movement and determination of the sample thickness simplify test preparation.
All test parameters as well as the calibration data are stored in the PC and documented.
Determination of thermal conductivity with the HFM 436 Lambda meets the industry standards ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667.
|
|
|
|
|
|
The Techne Sample Concentrator accelerates the concentration of large numbers of samples in a matter of minutes where traditional methods can take hours. It is ideal for the life science researcher and scientist; designed for applications such as sample preparation for analytical techniques including drug screening, hormone assays, chromatographic analysis and scintillation counting.
Evaporation is increased by passing an inert gas over the surface of the sample. The gas travels through the unique patented gas chamber to the samples via the needles. The needles are set into a silicone matrix and can be spaced to fit any combination of tubes.
The unit is light and compact enough for convenient use in a fume cupboard when toxic solvents are being evaporated.
Needles The needles are made from high quality stainless steel and are specially designed for use with the Techne Sample Concentrator. The needle configuration can easily be adjusted to fit any combination of tubes, from 26mm test tubes to 0.5ml microcentrifuge tubes. Where corrosive
solutions are being used, Teflon coated needles are available.
The Sample Concentrator's gas reservoir is mounted on a fully adjustable stand for accurate height control.
|
|
VLM Sample Concentrators are a time saving alternative to rotary evaporators, if there are many samples to be processed. For this purpose nitrogen is distributed by the gas dosing unit and introduced into the test tubes, flasks, chrom. vials, micro centrifuge tubes, or wells of microtiterplates The flow of nitrogen can be individually adjusted. The evaporation cold is compensated by the metalblock thermostats thus there is a constant temperature. Complete systems for 16,24,48, 96 (micortiterplates) are available with a convenient lift or - for small budgets - with a stand.
If samples have to be concentrated to a rest volume we recommend the EVA VIS model, which allows to watch the first row of samples placed into heating block with vertical slits. The evaporators shall be placed run in a hood but there is also a cabinet available you will find among accessories. For more information please visit our VLM Laborshop (www.vlm-laborshop.de) or give us a call 49 5205 87 963-0
|
|
|
|
|
|
The Anthos Instant Microplate Solution (AIMS) from Biochrom contains ALL the microplate instrumentation you need to run ELISA and other microplate based applications, in a single package, at a great price. It is ideal for laboratories that handle a large number of absorbance based assays that also need flexibility for future techniques. AIMS includes:
The Anthos Zenyth 200st Microplate Reader with cuvette UV/Vis spectrophotometer. A versatile monochromator based instrument that reads 6-384 well plates at any wavelength between 190-1000nm, with temperature control. The built-in spectrophotometer saves bench space, and there are pre-programmed cuvette methods for nucleic acid and protein measurements.
The Anthos Fluido 2 four channel microplate washer handles up to four different wash buffers, up to 50 different programs and 20 different plate types-including strip plates and round bottom wells.
In addition, the AIMS package contains ADAP Prisma PC analysis software and a laser printer free of charge.
AIMS includes the “top of the range” Anthos microplate instrumentation and software. All Anthos instruments are designed to give reliable results in busy multi-user laboratories for many years.They are CE marked and manufactured under a rigorous quality system.
Building on Anthos’ 25 years experience in microplate instrumentation, AIMS represents new thinking for the next generation providing total flexibility for microplate absorbance applications.
|
|
CENTRO LB 960
The Centro meets all currently known requirements for a versatile, robust and sensitive microplate luminometer. The selected detector and the proprietary design of the optical sytem guarantee lowest background and negligible crosstalk.
|
|
|
|
|
|
CentroPRO is the newest member of the microplate family of BERTHOLD TECHNOLOGIES. The instrument is universally applicable for research and routine. It enables the measurement of all important glow-type luminescence applications, e.g. reporter genes, ATP determination or cell viability.
Applications
Reporter genes
Dual reporter genes
ATP determination
Cell viability
Caspase
Kinases
Proteases
Monoaminoxidases
Mycoplasma contamination
Software
Easy operation via the innovative ICE software
(instrument control and evaluation)
Wizard guided definition of parameters
Various export formats (Excel®, PDF)
Intuitive menus
Single endpoint measurements
Dual label ratio calculations
Shaking
Specifications
Crosstalk: 10-6
Detection limit: 20 amol ATP
Detection limit: ~ 7.5 zmol firefly luciferase
Instrument Concept
Detector sensitivity and stability are the result of BERTHOLD TECHNOLOGIES experience with thousands of photon counters. True photon counting has the benefit that no user parameters need to be set, ensuring the same conditions are used for every measurement during the instruments life time. The fast photon counting circuitry provides a dynamic range in excess of six orders of magnitude, which complements the concentration range of the latest assays.
A patented design of the optical system achieves absolute minimization of cross-talk (down to 10-6 depending on the type of microplate).
Solid 96 well plates, as well 8 well and 12 well strip plates can be measured.
Inside the instrument precise x and y drivers ensure exact positioning of the wells with respect to the detector.
|
|
|
|
|
|
The Aurora Nephelometer delivers increased accuracy in studying particulates and their source of origin.
The effects of air pollution on human health and lifestyle are of a major concern today. There are many parameters contributing to air pollution, of which airborne particulates are a major contributor.
Nephelometers give indications of air quality by measuring the light scattering of particles in the air. This translates to visibility measurements and information for global warming studies.
The “new generation” of Aurora nephelometer is available in four models:
Aurora 1000 Nephelometer (single wavelength)
Aurora 2000 Nephelometer (PM2.5 correlation)
Aurora 3000 Nephelometer (3 wavelengths with backscatter)
Aurora 4000 Nephelometer (polar nephelometer)
The wavelengths are characterized as follows:
Blue : 450nm Fine & ultra fine particulates (wood fires, automobiles)
Green : 525nm Visibility (smog, fog and haze)
Red : 635nm Large particulates (pollen, sea salt etc)
Applications
- Visibility Measurements (Airports, City pollution, AAQMS)
- Dust/Sand storm monitoring and early detection networks
- Global warming studies (light scattering/radiation balance)
- Bushfire/pollution monitoring and early detection networks
- PM2.5 mass measurement correlation studies
Features
- Low power instrument (ideal for remote applications)
- Low maintenance
- Low cost of ownership
- Advanced LED light source
- Compact and portable
|
|
|
|
|
|
Artemis – High Performance HTRF® Microplate Reader
The Artemis K-101 has been designed for optimum performance with CISbio´s HTRF® reagents. The HTRF® approved instrument is extremely easy to use and guarantees superior performance even with demanding applications.
Dedicated Optics
The internal reflection epi-fluorescence optics paired with selected excitation and emission filters and a sensitive detector operated in single photon counting mode ensures best performance with low background and high sensitivity comparable to laser-based systems.
HTRF® compatible
The instrument has been validated for all of CISbio´s HTRF® reagents. Any HTRF® assay based on either the Europium or the new Terbium cryptates can be measured with superior performance. The HTRF® assay platform from CISbio offers the researchers a highly sensitive, robust technology for the detection of biological interactions such as G-Protein Coupled Receptor (GPCR), kinase and imflammation biomarkers among others.
Easy-to-use software
The Artemis is completely controlled by the MicroPlateReader software package. The HTRF® ratio calculation derived from the donor and acceptor signals, a patented method to correct for quenching and sample interferences, is automatically performed.
Specifications:
Measurement technology: HTRF®
Light source: High energy Xenon flash lamp
Detection System: Single photon counting PMT, 620 and 665 nm filters, sequential measurement
Plate formats: 96 and 384 well
Dynamic range: > 2000 % dF high std
Sensitivity: < 10 pg/mL TNFα
Reading time: 150 s (96 well, 20 flashes)
Software incl. HTRF® ratio calculation
Certifications: CE; HTRF® compatible
|
|
Biochrom Asys Expert 96 Microplate reader
A fast multi-channel filter based instrument controlled via a PC. Equally suitable for research and routine applications.
Features
- Fast - Just 9 seconds for a 96 well plate.
- Covers visible range 400-800nm or UV/Visible 340-800nm
- Very compact footprint.
- Common filters supplied as standard.
- Automatic self check and calibration routines.
- Front-loading allowing easy integration into robotic system.
- choice of software for data capture and analysis.
|
|
Biochrom Anthos 2010 Microplate Reader from Biochrom
The 2010 Microplate reader is a great value instrument designed for laboratories requiring a simple basic absorbance reader with PC control as a workhorse.
Key Features
-Single or dual wavelength measurements plus kinetic measurements
-4 commonly used filters supplied as standard 405nm, 450nm, 492nm and 620nm.
-8 position filter wheel -additional filters available
-Single, dual and kinetic measurements
-ADAP Basic software included
Optional
-Software upgrade to APAP Plus PC software or ADAP Expert.
-Reader check plate for QC
-Additional filters
|
|
|
|
|
|
Biochrom Anthos Zenyth 340 Microplate Reader
A fast, flexible, single-channel, filter based absorbance reader-equally suitable for research and routine applications. Available as a stand alone with built in software and a large graphical display, or PC controlled version.
- Fast, just 9 seconds for a 96 well plate
- Wide wavelength range 340 - 750nm for applications into the UV region.
- Commonly used filters supplied as standard.
- Excellent optical specifications (0.0001 Abs resolution)
- Handles multiple plate formats from 6 to 384 well plates.
- Highly flexible- single or dual wavelength for standard ELISA, kinetics linear scan and XY scanning.
- Choice of data analysis software packages
- Temperature control (option)
Additional Features for Stand Alone
-Large graphical display
-Comprehensive quantitative and qualitative data evaluation functions with curve-fits, cut-offs and transformation formulae
-Multiple kinetic data reduction modes, combined with further quantitative and qualitative evaluation
Variables, test-validation, automatic replicate elimination
-Integrated Windows CETM operating system, which offers full PC functionality and connectivity
Special Offer!
For a limited period we are offering a free laser printer to connect with the stand alone version of this microplate reader. Just add 80-5000-38 to your order, and you will receive a printer and cable to connect to your microplate reader completely FREE!
|
|
|
|
|
|
Plate CHAMELEON represents a new concept in multilabel detection instruments. Compact design houses up to 6 integrated technologies providing a powerful and flexible platform for the broadest spectrum of applications.
The technologies, widely employed in research and diagnostic applications, include
- Liquid Scintillation Counting (LSC),
- Luminescence (Lum),
- Fluorescence Intensity (FI),
- Time Resolved Fluorescence (TRF),
- Fluorescence Polarization (FP) and
- Absorbance (Abs).
A unique feature of Plate CHAMELEON is the patented detector head allocation adjustment. This ensures optimal counting performance when combining fluorescence measurements with ultra high sensitivity photon counting in luminescence.
Operation of Plate CHAMELEON is with easy-to-use Windows-based MikroWin software.
You can choose a Plate CHAMELEON model to meet your application needs. Different application modules are available. Thus your Plate CHAMELEON can be dedicated to LSC applications, or to non-radiometric applications. As a third alternative, to provide a complete spectrum of applications, both the radiometric and non-radiometric modules may be included.
|
|
|
|
|
|
Biochrom Anthos Zenyth 200 Microplate Reader
The Zenyth 200 is a high performance microplate reader with a built in UV/Vis cuvette spectrophotometer providing an indispensable research tool for Life Science laboratories that need a fast accurate plate reader to handle a large number of microplates e.g. ELISA screening and nucleic acid characterisation and measurement. It is avalable both as PC controlled version and as a stand alone plate reader.
- Forget filters! Covers the range 190 - 1000nm for future flexibility.
- Endpoint, kinetic, multichromatic, spectral scanning and position scanning
- Temperature controlled 4°- 45°C for kinetic studies.
- Fast, just 11 seconds for a 96 well plate.
- Multiple plate formats: cell culture plates (6-48) and 96/384 well plates.
- Choice of Software
The PC controlled version uses ADAP Basic software or can be upgraded to ADAP Prizma that includes both an advanced ELISA module and stored routines for cuvette assays including protein, nucleic acid and oligo concentration.
The stand-alone version has built in stored routines for nucleic acid quantitation and characterisation and integrated Windows CE(LAN - interface) for easy data transfer.
Special Offer!
For a limited period we are offering a free laser printer to connect with the stand alone version of this microplate reader. Just add 80-5000-38 to your order, and you will receive a printer and cable to connect to your microplate reader completely FREE!
|
|
Biochrom ASYS UVM 340 Microplate Reader
The UVM 340 is monochromator based scanning microplate reader providing fast, accurate analysis results particularly for Life Science and Pharmaceutical research laboratories. A high performance "top range" instrument ideal for laboratories wishing to maximise the applications that can be handled.
- Forget Filters!-complete wavelength coverage from 340-800nm
- Plate format capability from 12-96 well plates
- Fast wavelength scanning of single well in 5 sec
- Self check and calibration for total results confidence
- Front loading for integration into automated systems
- Choice of software packages
- Optional QC plate and software
|
|
|
|
|
|
The Dynamic Modulus Tester is a complete system that measures the velocity of the sonic pulses in materials such as fibers, films, tapes and papers. The test material is contacted by two transducers. The accurate measurement of the sound velocity between the transducers results in correct and repeatable dynamic modulus of elasticity.
APPLICATIONS
Fibers, Tapes, Nonwovens, Yarns, Polyester, Nylon, Spandex, Elastomeric, Monofilament, Carbon fiber and Glass fiber
ADVANTAGES
* Ensure product reliability and maintaining the manufacturer’s good name
* Quick information feedback
* Small, table-top instrument
* Controlling and lowering manufacturing costs
* Aiding in better product design
* Detect changes in polymer formula
* Maintaining a uniform quality level
FEATURES
* Digital display of the sonic velocity
* User friendly software program that calculates the dynamic modulus automatically
* Non-destructive testing for most materials
Operation
The Dynamic Modulus Tester is a complete system that measures the velocity of the sonic pulses in materials such as yarns, films, tapes, non-wovens, and papers. The test materials is contacted by two transducers. The DMT software calculates the sonic velocity, which is used to measure the physical and chemical structure of materials.
Properties Data
Strength, stiffness, elasticity, dyeability, resilience, fatigue, orientation and crystallinity.
Other uses
* Evaluation of experimental materials
* Production quality control
* Research, Assist in product development
|
|
|
|