Technical Data
Microprocessor based
Housing: ABS plastic.
Dimensions: 44 mm(diameter)x24.5 mm(height), installed in thermocouple head
Input: MV, pt100Ω, thermocouple available
Isolation: 4K Vac for 1 minute between sensor input and the 4~20mA loop
Electromagnetic compatibility: According to EN 50081-2, EN 50082-2
Internal protection against polarity inversion
Cold junction compensation for thermocouples
Thermocouples: Types J, K, R, S, T, N, E and B, according to IEC 60584-1 (ITS-90), lmpedance»1MΩ
Pt100: Excitation: 180μA
2 or 3-wire connection (for 2-wire sensors, tie terminals 2 and 3 together) α=0.00385, according to IEC 60751 (ITS-90)
Voltage: 0 - 50m Vdc; lmpedance»1MΩ
Total accuracy: better than 0.25% of the maximum range for thermocouples and 0.15% for Pt100 and voltage
Response time: ≦200ms
Output: 2-wire 4-20mA, linear with respect to the measured temperature
Resolution: 0.001mA (16 bits)
Power supply: 10 to 35Vdc, across the transmitter
Maximum load(RL): < 600Ω
Operating temperature: -40 to 85℃
Humidity: 0~90% RH
Common mode rejection ration (COMRR): >80dB