- Hydraulics - Pneumatics >
- Valve >
- Adjustment valve
Adjustment valves
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

DN: 15 mm - 150 mm
Pressure: 10, 16 bar
Durco T4E valves provide maximum corrosion resistance while eliminating product contamination at a reasonable cost. They are available with pneumatic or electric actuators for on-off or modulating control applications. Cost-effective ...
FLOWSERVE

DN: 15 mm - 100 mm
Pressure: 0 bar - 40 bar
Temperature: min -200.0 °C
Product line GS3 The sliding gate manual valve for low-temperature type 8056 in reinforced version is used for cryogenic control applications down to -200°C. Media such as hydrogen, nitrogen, oxygen, carbon dioxide, ...

DN: 3 mm - 12 mm
Pressure: 0 bar - 10 bar
Temperature: 0 °C - 70 °C
Compact needle valve in aluminium housing Leak-free valve Spring loaded, non rising adjustment stem with 56-pitch thread provides smooth, non-reversing flow characteristics and 15-turn ...

DN: 0.25 in
Pressure: 0 bar - 10 bar
Temperature: 0 °C - 70 °C
Compact needle valve in aluminium housing Leak-free valve Spring loaded, non rising adjustment stem with 56-pitch thread provides smooth, non-reversing flow characteristics and 15-turn ...

DN: 0.125 in - 1.5 in
Pressure: 1 mbar - 670 mbar
Temperature: -20 °C - 120 °C
Vacuum adjustment valves When these valves reach a certain pre-calibrated vacuum degree, they introduce atmospheric air into the circuit to prevent the increase of the set value and ...

DN: 1.5 in
Pressure: 15,000, 10,000 psi
Temperature: -5 °C - 50 °C
... system is supplied as standard; it consists of two pressure sensors across the throttling valve and a rotary variable differential transformer (RVDT) to provide valve position. Processing at the system ...

DN: 20, 15 mm
Pressure: 16 bar
Temperature: 2 °C - 110 °C
... change-over valve to connect one 2-pipe heat exchanger (Fan-coil Unit or Ceiling) to the 4-pipe system, ideally together with the Kombi-FCU Pressure Independent Control Valve used for dynamic balancing. VBG6 ...

DN: 40 mm - 600 mm
Pressure: 6, 10, 5 bar
Temperature: -10 °C - 160 °C
Thanks to their design and material diversity, centrally mounted, resilient seated shut-off and control valves are almost universally usable. Whether the medium is water, powder or gas - with a broad range of materials, ...

DN: 50 mm - 300 mm
Pressure: 10 bar
Temperature: -10 °C - 200 °C
Thanks to their design and material diversity, centrally mounted, resilient seated shut-off and control valves are almost universally usable. Whether the medium is water, powder or gas - with a broad range of materials, ...

DN: 150 mm - 400 mm
Pressure: 10 bar
Temperature: -10 °C - 200 °C
... close collaboration with our customers, for challenging fields of application that simply require more than a standardised valve product. This has resulted in countless variations. Many of them have been developed to ...

DN: 0.125 in - 1 in
Pressure: 2.5 bar - 13 bar
Temperature: -5 °C - 50 °C
• Progressive start-up valve • Available in 4 sizes with flow rates up to 15000 Nl/min and connections from 1/8” to 1” • Suitable for downstream system gradual pressurization • Downstream circuit filling time regulated ...

DN: 8 mm - 25 mm
Pressure: 10,000 psi - 20,000 psi
Needle Valves, SM Series - 20,000 PSI | #20SM4071 Parker Autoclave's SM Series needle valves are a non-rotating rising stem design, with working pressures to 20,000 psi (1379 bar). Tubing sizes range ...

Pressure: 0 bar - 350 bar
Temperature: -30 °C - 120 °C
Flow rate: 40 l/min
... options Adjustable by allen key or hand screw, optionally sealable (lockwire holes) In the standard version, the valve is zinc-coated for 240 h protection acc. to ISO 9227
ARGO-HYTOS

DN: 6 mm
Pressure: 210 bar
Temperature: -20 °C - 80 °C
Industrial hydraulic valve in a high performance range. Reliable oil flow control to command value signal. Spool valve Pilot-operated Connection diagram - ISO 4401-03-02-0-05 Spool symbol ...

DN: 8 mm - 50 mm
Pressure: 0 bar - 4 bar
Temperature: -20 °C - 90 °C
Adjusting cocks for precise flow rate adjustment. Operated by hand wheel with adjusting scale DIN-DVGW tested and registered Tool-operated.LEH: Operated by hand wheel Connection: internal ...
Honeywell Thermal Solutions

Pressure: 350 bar
Temperature: -40 °C - 80 °C
Flow rate: 320, 30, 150, 75 l/min
The load-holding valve type CLHV is suitable for applications with low and medium tendencies to oscillate and is used especially in connection with proportional directional spool valves, e.g. types PSL ...
HAWE Hydraulik SE

Pressure: 600, 400, 500 bar
Flow rate: 60, 20, 40 l/min
... pressure-dependent shut-off valve type DSV is used as a safeguard pressure gauge, for example. The valve type DSV is available for pipe connection or manifold mounting. Features and advantages ...
HAWE Hydraulik SE

Pressure: 500, 420 bar
Temperature: -40 °C - 80 °C
Flow rate: 40 l/s
The type OSCA-D load-holding valve is especially suitable for applications that are either particularly susceptible to vibration or that work with very high load pressures. The valve is designed as ...
HAWE Hydraulik SE

DN: 0.28 mm - 1.4 mm
Pressure: 0 psi - 200 psi
... orifice and check valve. The orifice meters flow in the forward direction, while the check valve permits free return flow. This valve is particularly well suited for control of small ...
Beswick Engineering Co, Inc.

DN: 0 mm - 1.4 mm
Pressure: 0 psi - 200 psi
The Beswick MIL-MV series metering valve contains an adjustable orifice. The orifice meters fluid flow, regardless of flow direction through the valve. The o-ring seals fit to make the valve ...
Beswick Engineering Co, Inc.

DN: 0 mm - 0.81 mm
Pressure: 0 bar - 34.7 bar
... version is especially well suited for control of low flow rates. Adjustment: All versions come equipped with a 1-72 threaded adjustment screw. About 4 revolutions of the adjustment ...
Beswick Engineering Co, Inc.

DN: 15 mm - 65 mm
Pressure: 10 bar
Temperature: -20 °C - 120 °C
DIALOCK® diaphragm valve with stroke limiter and male ends for solvent welding, metric series. The DK DIALOCK® diaphragm valve is particularly suitable for shutting off and regulating abrasive or dirty ...
FIP - Formatura Iniezione Polimeri

DN: 15 mm - 65 mm
Pressure: 10 bar
Temperature: -20 °C - 120 °C
Pneumatically actuated diaphragm valve with male ends, metric series. Normally Closed function. The DK diaphragm valve is particularly suitable for shutting off and regulating abrasive or dirty fluids. ...
FIP - Formatura Iniezione Polimeri

DN: 15 mm - 65 mm
Pressure: 10 bar
... lifetime New design of valve body interior: substantially increased flow coefficient and reduced pressure drop. The degree of efficiency reached has also enabled the size and weight of the valve ...
FIP - Formatura Iniezione Polimeri

DN: 15, 25, 20 mm
Pressure: 16 bar
Temperature: 5 °C - 160 °C
BY-PASS BRASS Sintesi ball valve BY-PASS MMMM BRASS with caps and tangs

DN: 25, 15, 20 mm
Pressure: 16 bar
Temperature: 5 °C - 160 °C
2 way MM Sintesi ball valve for SOLAR HEATING SYSTEMS 2-way MM BRASS with caps and tangs With high temperature seal (up to 160°C) and SPACER for THERMAL CUT

DN: 50 mm - 60 mm
Specifications Valve types • regulating valve, elbow regulating valve • fine regulating valve, elbow fine regulating valve • taper seat non-return ...

DN: 25 mm - 400 mm
Pressure: 0 bar - 10 bar
Temperature: 220 °C
Energy saving valve for the precise and economical control at low loss of pressure of liquids and gases that can be either clean or contain particles. Applications - Air for aeration in wastewater treatment plant - ...

DN: 0.375 in
Pressure: 0 bar - 10 bar
Temperature: 0 °C - 23 °C
... float valves meet the highest quality and safety standards, making them perfect for use in drinking water applications. Key Features of the PVA Compact Float Valve Series 481 Continuous Level ...

DN: 0.5 in - 2 in
Pressure: 2 MPa
Temperature: -20 °C - 120 °C
Brass threaded motorized control valves of ES100/ES150 and BL220/BL350 series apply to HVAC (heating, ventilation, and air conditioning), and building automation systems. Once the motorized control valves ...
Taloar

DN: 2 in - 12 in
Pressure: 235 psi
Temperature: -20 °C - 120 °C
2 ″ - 12 ″ PN16/235PSI/Class125 220V/380V · Multi-stage alloy steel reduction gears and worm · Over-torque protection · Moisture-proof heating resistor · Epoxy resin coating · 90° rotation · IP67 protection Threaded Hole Lug ...
Taloar

DN: 14 in - 32 in
Pressure: 235 psi
Temperature: -20 °C - 120 °C
14 ″ - 32 ″ PN16/235PSI/Class125 220V/380V · Multi-stage alloy steel reduction gears and worm · Over-torque protection · Moisture-proof heating resistor · Epoxy resin coating · 90° rotation · IP67 protection Threaded Hole Lug ...
Taloar

Pressure: 22 MPa - 25 MPa
Temperature: -20 °C - 80 °C
Flow rate: 20 l/min - 100 l/min
... double-acting cylinders. The second link is equipped with pressurecompensation flow adjustment function, which effectively saves energy and reduces consumption. The valve bodyadopts electrophoretic coating, ...

DN: 3, 4, 6 in
Pressure: 14.2 psi - 170.6 psi
Temperature: -15 °C - 80 °C
... Application of Groove End Pilot Control Pressure Reducing Valve Our Groove End Pilot Control Pressure Reducing Valves are most suitable for Hydraulic systems. Hydraulic Pressure Reducing Valves ...

DN: 1.5 in - 12 in
Pressure: 1 bar - 13 bar
Model DTR / DFR, Diaphragm pilot control Pressure Reducing Valve reduces pressure of inlet flow into desired outlet pressure. Pressure Reducing Valve can prevent damage within pipelines due to high pressure. Features ◆ ...

DN: 2.5, 1.5 in
Pressure: 2 bar - 7 bar
Model HRTL/HRTR, Fire Hydrant Pressure Reducing Valve, function similar to landing valve, attached in hydrant box serve as connector between pipeline and hydrant hose. Our Fire Hydrant Pressure Reducing ...

Pressure: 0 bar - 40 bar
Temperature: 95 °C
Externally controlled valve for the hydrogen sector Valves for hydrogen and oxygen in electrolyser operation Pneumatically operated 2/2-way valve - Direct pressure control Designed ...

DN: 0.312 mm
Pressure: 0 psi - 180 psi
Temperature: -40 °C - 93 °C
... Stainless Steel construction provides excellent corrosion resistance. Flow control needle has 7 to 8 turns of precision adjustment, and maximum flow approximately equal to a 0.025″ orifice. Unique laminar flow design ...

DN: 2 in - 6 in
Pressure: 50 mbar
Temperature: -20 °C - 60 °C
Male threaded emergency vent is normally used to protect the aboveground storage tank from overpressure. It has 50 mbar pressure relief. It even helps to reduce the evaporation of fuel and environmental pollution. material: - ...
Your suggestions for improvement:
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining