DN: 0 mm - 10,000 mm
Pressure: 0 Pa - 689,480,000 Pa
... shuttle valve
Advantages for system designers and maintenance
- Enables
DN: 1.813 in - 56 in
Pressure: 2,000 psi - 10,000 psi
... Double Block and Bleed Valve is a side-entry ball valve, with either a bolted or welded body, designed for use in upstream, midstream and downstream oil and gas applications. It requires two in-line isolation valves ...
DN: 15 mm
Pressure: 25 bar
Temperature: 1 °C - 120 °C
... Pre-adjustable Combi valves, PN 25, internally threaded for ventilation and air conditioning plants for control on the water side and automatic hydraulic balancing of terminal units, such as fan coils, induction ...
Siemens Building Technology HVAC Products
DN: 15 mm - 50 mm
Pressure: 16 bar
Temperature: -10 °C - 120 °C
... control valves combine a differential pressure regulating mechanism with a full stroke control valve to achieve optimized flow control across a wide spectrum of varying system pressures and flow rates. The V5004TY ...
DN: 0.5 in
Pressure: 0 bar - 17.2 bar
... These valves are used to automatically drain water from components or valves that are normally dry, such as an alarm line or control valve at a hose station Features Model AD-1: designed for use ...
Total
DN: 0.25, 0.375, 0.5 in
Pressure: 0.1 MPa - 1 MPa
Temperature: -5 °C - 60 °C
... ・Improved foreign matter resistance ・Increase in condensate discharge Drain discharge: Max. 100 cm3/cycle (3 times that of the current model) ・Improved environmental resistance: Transparent bowl guard can protect the inner bowl ・Improved visibility: ...
DN: 0 mm - 0 mm
... control
valves at hose stations)
Technical Resources
- Technical Data Sheet TFP1630 — Automatic Drain Valve (trim component for dry pipe, deluge, and preaction valves)
- Technical
DN: 100 mm - 1,000 mm
Pressure: 0.4, 0.5, 1, 0.3 bar
... dust accumulation level in the valve body and the blade position which meets the requirements of OSHA Combustible Dust Directive, NFPA 654, and NFPA 69. The IsoFlap and IsoFlap-M both have a durable carbon steel valve ...
DN: 4 mm
Pressure: 2 bar - 10 bar
Temperature: 0 °C - 60 °C
... pressure window incorporated, which allows an easy detection of any problems. Moreover the fittings are incorporated into the valve body and are super-rapid ø4. The “NOT” element has an actuating pressure of 0,3 bar. ...
CAMOZZI AUTOMATION
DN: 40 mm - 100 mm
Pressure: 0.5 bar - 10 bar
... technology. The IR-910-MC-KX will regulate your irrigation system in the most accurate way. Both the valve and the water meter can be setup to any automatic irrigation scheduling and can be accessed locally and remotely ...
BERMAD CS Ltd
DN: 15 mm - 300 mm
Pressure: 16 bar - 63 bar
Temperature: -60 °C - 550 °C
... Control valves applied to occasions where there is no external energy on site, the control accuracy is not high, and automatic pressure stabilization control is required. Features Various valve ...
Hollysys
DN: 1.6 mm - 3.2 mm
Pressure: 100 psi
... Beswick selector valve can be used as a quiet replacement for solenoid valves in many applications, and has the ability to operate from a servo motor. The SVPC series rotary selector is a variation of the SV, with integral ...
DN: 0.125, 0.25, 0.375 in
... Shut-off valves These are special one-way valves that, when properly calibrated, allow a certain quantity of fluid to go through; afterwards, if the fluid continues to go through, they automatically close. These shut-off ...
DN: 1.5 mm - 56 mm
Pressure: 0 psi - 142.2 psi
Temperature: -15 °C - 80 °C
... / BFF, The float valve has one major function and that is to stop the flow of water from an inlet supply line. The float valve rises as the water level rises. Once a specified water level is reached, this will cause ...
DN: 1.5 in - 56 in
Pressure: 0.3 psi - 8 psi
Temperature: -15 °C - 80 °C
... Presssure Sustaining Valve, also known as Back Pressure Valve, or Back Pressure Sustaining Valve, is a valve that maintain required pressure of inlet port by opening only as much as required. What ...
Pressure: 2.5 bar - 15 bar
Temperature: 0 °C - 60 °C
... The Elcometer AGV Automatic General Valve ensures precision abrasive control and fail-safe shut down of both the blast stream and media flow. The Elcometer AGV Automatic ...
... The Elcometer General Valve Conversion Kit converts an Elcometer GV General Valve into an AGV Automatic General Valve. The Elcometer GV General Conversion can be easily ...
DN: 4 mm
Temperature: -18 °C - 93 °C
... sensing technology • Direct valve-to-vacuum cup mount Note: These valves are designed to not seal shut completely. This purposeful small vacuum loss allows the valves to have immediate vacuum when ...
DN: 6.35 mm
Pressure: 0 psi - 150 psi
Pressure: 4.1 bar - 60 bar
DN: 15 mm - 50 mm
Pressure: 0 bar - 40 bar
Temperature: -30 °C - 220 °C
... Pneumatically operated globe valve type 7027 with integrated positioner for control applications with neutral to highly aggressive media. The straight design enables a highly efficient and very simple insulation of the valve ...
DN: 15 mm - 50 mm
Pressure: 0 bar - 40 bar
Temperature: -30 °C - 220 °C
... operated globe valve type 7027 with integrated positioner (type 8049 with IO-Link) for control applications with neutral to highly aggressive media. The straight design enables a highly efficient and very simple insulation of the valve ...
DN: 15 mm - 80 mm
Pressure: 40 bar
Temperature: -30 °C - 200 °C
... Motor valve for on/off- and modulating operation for neutral and aggressive media. •Size: DN 15 up to DN 50 •Pressure: PN 40, ANSI #150 •Material: Stainless steel 1.4408 •Temperature: -30°C up to +200°C optionally up ...
DN: 4 mm - 25 mm
Pressure: 0 bar - 8 bar
Temperature: -10 °C - 100 °C
... Diaphragm valve - 650TL Diaphragm valve GEMÜ 650TL is a manual tapping valve with automatic closing function which is pneumatically operated. The "keep-closed" override of manual operation ...
DN: 50 mm - 600 mm
Pressure: 25 bar
Flow rate: 16 m³/h - 5,400 m³/h
... PRESSURE REDUCING VALVE The valve reduces high upstream pressure to a pre-set lower and constant downstream pressure level, regardless of fluctuating flow or varying upstream pressure. A hydraulic regulating pilot ...
DN: 50 mm - 600 mm
Pressure: 25 bar
Flow rate: 16 m³/h - 5,400 m³/h
... PUMP CONTROL VALVE The valve isolates pumps from the system during pumps starting and stopping to protect pipe lines and pumps itself. The valve is equipped with a control solenoid valve ...
DN: 800 mm - 1,400 mm
Pressure: 1 bar - 25 bar
Flow rate: 3,900 m³/h - 23,200 m³/h
... The valve shall be made with high hydrodynamics section globe body, without stagnation pockets (conical, low pressure loss type), the main valve body and cover shall be made in standard ductile cast iron casting GJS500-7 ...
DN: 100, 80, 65, 50 mm
Pressure: 40, 25, 16 bar
Temperature: -20 °C - 110 °C
... respectively. Supplying power by means of a phase across terminal 2 causes the valve to close (electrical automatic closing); supplying power across terminal 3. too. causes the valve to open. ...
Comparato Nello S.r.l.
DN: 50, 40, 32 mm
Pressure: 10 bar
Temperature: -20 °C - 110 °C
... respectively. Supplying power by means of a phase across terminal 2 causes the valve to close (electrical automatic closing); supplying power across terminal 3. too. causes the valve to open. The figures ...
Comparato Nello S.r.l.
DN: 40, 50 mm
... respectively. Supplying power by means of a phase across terminal 2 causes the valve to close (electrical automatic closing); supplying power across terminal 3. too. causes the valve to open. The figures ...
Comparato Nello S.r.l.
DN: 0.5 in - 1 in
Pressure: 0 bar - 19 bar
... Hyperr Valves Pvt Ltd is a leading manufacturers, supplier and exporter of Pressure Reducing Valves. Our Pressure Reducing Valve is engineered to automatically reduce a high, fluctuating inlet pressure ...
Hyperr Valves Private Limited
DN: 0.5 in - 6 in
Pressure: 0 bar - 100 bar
... Hyperr Valves Pvt Ltd is a leading manufacturers, supplier and exporter of Pressure Reducing Valves. Our Pressure Reducing Valve is engineered to automatically reduce a high, fluctuating inlet pressure ...
Hyperr Valves Private Limited
DN: 0.5 in - 3 in
Pressure: 0 bar - 7 bar
... Hyperr Valves Pvt Ltd is a leading manufacturers, supplier and exporter of Pressure Reducing Valves. Our Pressure Reducing Valve is engineered to automatically reduce a high, fluctuating inlet pressure ...
Hyperr Valves Private Limited
Pressure: 0.2 bar - 8 bar
Temperature: 1 °C - 75 °C
Flow rate: 12, 17, 35 l/min
... diaphragms replaceable).
Datasheet (key parameters)
Product name: Urinal Toilet Flush Solenoid Valve
Model: WL2862
Rated Voltage ...
DN: 3, 0, 4 in
Pressure: 230 mbar - 8,000 mbar
Temperature: -20 °C - 40 °C
... . 10/520 19/03/1955 and subsequent amendments. Valve is used to prevent any possible overfill during charging hazardous or dangerous fluids. Application: petrochemical. food. pharmaceutical & more. Valve opens and closes ...
Ridart srl
DN: 3, 4 mm
Pressure: 230 mbar - 8,000 mbar
Temperature: -20 °C - 60 °C
... 520 19/03/1955 and subséquent amendments. Valve is used to prevent any possible overfill during charging hazardous or dangerous fluids. - Application: petroc hernie al. food. pharmac eutic al & more. - Valve opens ...
Ridart srl
DN: 3 in
Pressure: 230 mbar - 8,000 mbar
Temperature: 60 °C
... /EU. ISO EN 13616-1, Technical Norm Fire Prévention 41/256 31/10/2019. d P.R. 10/520 19/03/1955 and subseguent amendments. Valve is used to prevent any possible overfill during charging hazardous or dangerous fluids. - - Application: ...
Ridart srl
DN: 50 mm - 1,000 mm
Pressure: 25, 10, 16 bar
Temperature: -20 °C - 70 °C
... Pressure reducing valves Pressure sustaining valves Altimetric valves Float controlled valves Technical Features of Flowrates Control Valves ...
DN: 150 mm - 2,000 mm
Pressure: 25, 40, 16, 10 bar
Temperature: -10 °C - 70 °C
... according to DIN 32711 Main disc sealing ring made of EPDM according to EN 681-1 WA, WB Internal and external surface protection made of epoxy resin powder (FBE), blue colour RAL 5015 and thickness of 250μm Soft sealing ...