- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Electrical cable
Electrical cables
Cross-section: 0.25 mm²
Length: 500 m
... Description
RTD
cable 3×0.25 mm² designed for wiring and extension of Pt100 probes and 3‑wire RTD sensors in industrial temperature measurement and control installations.
Materials and construction
Made with ...
Cross-section: 0.22 mm²
... indicates use as an extension
cable for Type T thermocouples, providing a compact, technically insulated connection suitable for industrial instrumentation and control applications.
Cable characteristics
- Cable
Temperature: -55 °C - 200 °C
Cross-section: 1.3 mm² - 1.3 mm²
... extension
cable KX 2 × 1.3 mm², Class 1, with SSB conductors, individual silicone rubber insulation and silicone outer jacket. Compliant with IEC 60584-3. Operating range: -55 °C to +200 °C.
Description
The KX Type K ...
Temperature: -10 °C - 105 °C
Cross-section: 0.44, 0.75, 0.22 mm²
PVC inner and outer providesa good general-purpose cableideal for extension leads. PVC is waterproof and is self-extinguishing, it has a high dielectric strength, good mechanical properties and provides resistance to chemicals, oil, hydrocarbons and abrasion. ...
Temperature Technology Ltd
Temperature: -200 °C - 260 °C
Cross-section: 0.22, 0.08 mm²
Conductors are PFA insulated, laid flat with an overall PFA jacket.
Temperature Technology Ltd
Temperature: -60 °C - 400 °C
Cross-section: 0.22, 0.08, 0.03 mm²
Fibreglass inner and outer offers a great resistance to high temperatures with good dielectric properties. Conductors are Fibreglass insulated, laid flat and insulated with an overall Fibreglass jacket impregnated with silicon varnish.
Temperature Technology Ltd
... USB-C data cable to USB-A. Application / usage - ATEX zone ...
Nominal voltage: 5 kV
Temperature: -70 °C - 260 °C
... PEEK LCD Cassette Support Wire Specially designed for glass substrate cassettes, it can significantly reduce particle generation; ultra-high purity and low outgassing properties prevent contamination. ...
Nominal voltage: 300, 400 V
Temperature: -70 °C - 260 °C
... Retention calculates the activation energy of the insulation coating material. Application Single-core wires or multi-core cables are used in nuclear power plants. 1. Advantages The elongation of PEEK insulation is between ...
Nominal voltage: 600 V
Temperature: -200 °C - 300 °C
... maglev field. Medical equipment MRI signal cables, detection of superconducting magnets and their feeder systems, superconducting solenoid signal cables, ultra-low temperature and high field insulated cables. Advantages ...
Temperature: -20 °C - 80 °C
Length: 1, 3, 5, 8, 10 m
... active optical cables has been launched, which can achieve more than 5 million back and forth bends without frame drops. AOC improves cable speed and distance performance by performing electrical-to-optical ...
Odinvision
Temperature: -20 °C - 85 °C
Length: 1, 3, 5, 8, 10 m
... real-time data transmission ◆ Stable cable material, can use standard coaxial cable - such as RG59 and Rg6 ◆ Easy to integrate: video transmission, serial communication control and power supply can be realized on ...
Odinvision
Temperature: -35 °C - 85 °C
Length: 1, 3, 5, 8, 10 m
... ◆ Oil-resistant sheath for industrial environments. ◆ Specially prepared shielding improves anti-interference performance. ◆ The original imported Japanese HONDA connector, support PoCL power supply. ◆ It is made of special polymer with high ...
Odinvision
... UNIPOLAR CABLE REEL, 500 M LENGHT, FOR VES Description Unipolar cable for quadrupole surveys, equipped with stainless steel spring plug connector and PVC protective cap to ensure best connection between ...
M.A.E. S.r.l.
... Description Geoelectric prospection cable for electrodes connection to Mae instruments. Due to multitouch cable with flexible TPE insulation and yellow polished PUR sheath, Mae cables feature an high ...
M.A.E. S.r.l.
Length: 250 m
... Unipolar cable for quadrupole surveys, equipped with stainless steel spring plug connector and PVC protective cap to ensure best connection between electrode and cable and to protect connector ...
M.A.E. S.r.l.
Nominal voltage: 350 V
Temperature: -20 °C - 70 °C
Cross-section: 0.14 mm²
... flexible Flat Ribbon Cable in 0,14mm², with molded, colored conductors by VDE 0812 ...
Metrofunk Kabel-Union
Nominal voltage: 350 V
Temperature: -20 °C - 70 °C
Cross-section: 0.5 mm²
... flexible Flat Ribbon Cable in 0,50mm², with molded, colored conductors by VDE 0812 number of cores: - 2, 3, 4, 6, 8, 10, 12, 16 ...
Metrofunk Kabel-Union
Nominal voltage: 350 V
Temperature: -20 °C - 70 °C
Cross-section: 0.25 mm²
... flexible Flat Ribbon Cable in 0,25mm², with molded, colored conductors by VDE 0812 number of cores: - 2, 3, 4, 6, 8, 10, 12, 16, 20 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 600, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.38 mm² - 95 mm²
IC AUTOMATION
Nominal voltage: 300, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.08 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
... Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without green-yellow conductor ...
Cross-section: 1.5, 1 mm²
... The self-supporting electrical control cable engineered by By carpel is supported by dual side ropes that are inserted in the exterior sheath. This tool is specifically utilized on applications such as lifting sytems, ...
Nominal voltage: 600 V
Temperature: -190 °C - 180 °C
Cross-section: 0.34 mm²
MURRELEKTRONIK
... ● 1.0mm VNA Cable Operating to 110 GHz● Lightweight, protective VNA test cable armoring● Precision 1.0mm stainless steel connectors● Excellent amplitude and phase stability with flexure● Non-conductive protective Nomex® ...
Cross-section: 16 mm²
Length: 15 m - 30 m
... twistlock connectors on the two HOFR power cables; thermocouple plug on the compensating cable
Globe Heat
Length: 0 m - 1,000 m
... in two different versions: As a trunk cable for distances of up to 1000m between the switches As a spur cable, which can be used as a connecting cable for a device with a length of up to 200m. Spur ...
BizLink Robotic Solutions Germany GmbH
Nominal voltage: 1,000 V
Temperature: -20 °C - 60 °C
... Copper data Office cables Office data cables for future requirements The data transmission according to 1-10 Gigabit-Base-T is based on a full-duplex principle i.e. via all cable pairs at the same ...
Prysmian Group
... Axon’ has designed tailor-made composite cables for 50 years. The company has integrated the manufacture of conductors (silver plated copper, tin plated copper, nickel plated copper,etc), the assembly, taping, shielding, and jacketing. ...
Axon Cable
Nominal voltage: 600 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
... POWERFLEX® RV-K cable is suitable for all types of low voltage industrial-type connections, in urban grids, building installations, etc. Its high flexibility makes the installation process substantially easier and, as a result, is particularly ...
Top Cable
Temperature: -30 °C - 80 °C
Cross-section: 0.52 mm²
Length: 30.5 m - 304.8 m
... >EL147 Standard
Cable Dimensions (Part / Continuous Roll / Description)
Part# | Continuous Roll | Description
15515 | 100 ft | Six-conductor
cable
15516 | 250 ft | Six-conductor
cable
15517 ...
Temperature: -30 °C - 60 °C
... optimized design of high-speed cable pitch technology production process greatly improves crosstalk And the transmission performance index margin such as return loss, etc., to obtain a higher transmission bandwidth. Adopt unique cable ...
Zhaolong Interconnect
Nominal voltage: 1 kV
Temperature: -20 °C - 90 °C
... voltage 0.6/1kV NFC 33209 Aerial Bundle Cable The aerial bundle cable is mainly used for 600V overhead secondary distribution lines. Standards: NFC 33-209 1.The long-term allowable working temperature ...
Henan Tong-Da Cable Company
Nominal voltage: 3 V
Temperature: -40 °C - 85 °C
Length: 1, 7, 3, 5 m
... QSFP+ Direct Attach Cables are compliant with the SFF-8436 specifications. Various choices of wire gauge are available from 30 to 26 AWG with various choices of cable length (up to 7m). Applications ...
T&S Communications
Nominal voltage: 76 kV - 500 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... you: from consulting on design through to implementation of your sophisticated high-voltage cable systems. Brugg Cables advises customers world-wide on new cable systems, as well as expanding or converting ...
Brugg Kabel AG
Temperature: -40 °C - 150 °C
Cross-section: 0.13 mm² - 120 mm²
Ningbo KBE Electrical Technology
... This sensor cable is comprised of 20-gauge, shielded cable with drain wire and soldered terminal connectors for easy field installation. Description ApplicationWiring standard RNRG ...
NRG Systems
Nominal voltage: 600 V
... the next generation of control cables. By combining better performance and minimum environmental impact, EcoCable uses its mPPE insulation and jacketing to provide all of the advantages in a smaller, lighter control cable. Up ...
Alpha Wire
... PVC control cables · unshielded Flexible PVC control cables Machine and device construction, transport and conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement ...
LÜTZE
... material HDPE, the shape of the cable offers reduced contact surface to its low friction sheath. ACOPTIC® is the range of ACOME’s optical cables solutions for telecom networks. MCD1521-HD cables ...
Acome
Temperature: 90 °C - 260 °C
Length: 15 mm - 55 mm
... Our automotive cables are the reliable and efficient connection for each wiring system. We offer an extensive range of products with various OEM and Tier 1 approvals. We supply both by international standards and the specification of ...
LEONI
Nominal voltage: 6 kV - 50 kV
Cross-section: 35 mm² - 240 mm²
... Our MV connecting cables consist of a cable with connector fittings at their ends. Our connecting cables are designed and customized on demand, according to your needs. Each MV connecting ...
Comeca Group
Nominal voltage: 220 kV
Temperature: 90 °C
Cross-section: 240 mm² - 2,500 mm²
... 5S ), the conductor temperature: not exceed 250 ℃ 4、0℃,≥18D (D) The minimum temperature of cable laying: 0℃ The minimum bending radius≥ 18D (D is the cable outer diameter ) ...
Shanghai Morn Electric Equipment Company
Temperature: 90, 70, 80 °C
Hubei Xinghe Electric New Material
Nominal voltage: 2,000, 1,500, 1,000 V
Cross-section: 1.5 mm² - 35 mm²
Nominal voltage: 450 V - 1,000 V
Temperature: -60 °C - 180 °C
... Single-conductor cable, silicone insulation with reinforcement, silicone-coated polyester braid, flexible, bare copper core Applications : Electromechanics Shipbuilding, railways Cabinets Approvals : Veritas Industrie (VERITAS) Operating ...
OMERIN
Nominal voltage: 600 V - 1,000 V
Temperature: -30 °C - 80 °C
... Stendalto's BC420N is a flexible copper cable that weighs 96 kg/m, with 156 kg/m cable weight. Its power is black num. 1-2-3 +G/V, while its signal is black num. 5-6-7-8. The model's jacket is made of black PUR. The ...
Brevetti Stendalto
Temperature: -25 °C - 75 °C
Length: 1,000 m
... polyester screen with a continuity wire and LS0H sheath. This is a telephone cable for indoor installations. Telecommunications cable Flame retardant Low smoke emission UV resistant Zero halogen ...
CABLESCOM
Nominal voltage: 48 V
... Electrical and Optical Fiber Composite Cable Product Features 1. The lines equipment capacity of remote supply system for electric and optical fiber composite cable is more flexible. ...
Tongguang Group Company
Nominal voltage: 15, 33 kV
... -6 EN 50182 Application The XLPE covered conductors are used primarily for, but not limited to, overhead secondary distribution lines. Installed on insulators, otherwise treated as a bare conductor. The conductors are sometimes referred ...
Sunway Company
Nominal voltage: 600 V - 1,000 V
Temperature: 0 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... Short-circuit temperature tolerance: up to 250°C for 5 seconds.
Guangzhou Yuhong Technology CO., Ltd
Nominal voltage: 300 V - 500 V
Temperature: -40 °C - 80 °C
... Control system cables, class 5 flexible, 300/500V, general shielding by tinned copper braid, PVC sheath. Marking of numbered black conductors with or without green and yellow. CAELIFLEX B shielded cables are used as ...
CAE GROUPE
... 15-Pin shielded signal cable available for UIO/UMX ...
Temperature: -200 °C - 1,700 °C
... Mineral insulated cable is widely applied in industry, a proven choice for high temperature probe fabrication. High temperature resistance, anti-corrosion, anti-oxidation,long life time and rapid heat response. Sheath material can be ...