- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flow meter
Flow meters
Process pressure: 0 psi - 50 psi
... Regulators Warnings Flowmeter Flowmeter Part No. FM-100F Ideal for HVAC and refrigeration brazing or purging applications. Brazing without nitrogen causes internal oxidation scale that can flake off and damage the parts ...
Volumetric flow rate: 0 l/min - 0.2 l/min
Precision: 0.01 %
... An in-line flow meter with an advanced straight sensor tube and restrictor flow element to give a high degree of accuracy. Pre-calibrated for air at an inlet pressure of 5 to 60 psi, with a gas temperature ...
Process pressure: 3.5 bar
Provides high reading accuracy of the operating pressure indicated on the internal scale (3.5 bar). The inner ball is easily visible and immediate reading is provided thanks to the presence of the two-colour silk-screen column (black writing on a white ...
OXYTURBO SPA
Volumetric flow rate: 20 l/min - 120 l/min
Process pressure: 3.5 bar
Precision: 3 %
... Flow meter for streaming liquids according to the measurement principle of a swashplate. Description For diesel, heating oil EL/L, radiator antifreeze (concentrate), RME, vegetable oil Plastic/aluminum housing Flow: ...
HORN GmbH & Co. KG TECALEMIT
Process temperature: -40 °C - 60 °C
Process pressure: 0 psi - 50 psi
... system makes the Amazon Bubbler an attractive solution for real-time monitoring and data collection. The Amazon provides a continuous air bubble and an integrated pressure sensor that measures the pressure required to push the bubble ...
Volumetric flow rate: 50 l/h - 60,000 l/h
Process pressure: 10 bar
... The flow meter operates on the float principle and is used for flow rate measurements in closed pipelines. The medium flows through the vertically installed flow meter ...
Process temperature: -45 °C - 85 °C
... Velocity Radar/Sensor uses OTT SVR 100 to measure flow in open channels and rivers continuously and without contact. For more information about it please visit: https://www.ott.com/products/water- flow-3/ottsvr-100-2406/ SenSpot™ ...
... inductive flowmeters for the dosing of water. With the mechanical flowmeter dosing takes place using a standard mechanical clock. The magnetic inductive flowmeter is used when high dosing accuracy ...
... Ultrasonic Flow Sensor [Features] ● Measurement: Flow rate ● Measuring range: Flow rate: 0~±30m/s; Temperature (for heat meter function): Standard: -30~90℃; High temp. -30~160℃ ● ...
Volumetric flow rate: 0.5 us gal/min - 10.5 us gal/min
Process temperature: -25 °C - 80 °C
Process pressure: 10 bar
... The TF Series is a multi-function true union paddlewheel flow meter. The TF Series Paddlewheel Flow Meter provides high accuracy economically while ideal for thermoplastic piping systems. The TF Series ...
Volumetric flow rate: 10 l/min - 100 l/min
Process temperature: -40 °C - 80 °C
Precision: 0.5 %
... Series 1" DIGITAL FLOW METER are suitable for flows between 6 - 120 L/min (1.59 - 31.70 GPM), providing highly accurate flow measurement performance. The MX Series offers ±±0.5% accuracy ...
Volumetric flow rate: 1 l/min - 60 l/min
... This range of oxygen flowmeter with humidifer is for the metered delivery of gas ,giving flow rates of between 1 and 15 L/min(other flow ranges available) in addition, it can provide an uncalibrated flow ...
Volumetric flow rate: 40 m³/h - 313 m³/h
Process temperature: 0 °C - 50 °C
Process pressure: 16, 10 bar
... STANDARDS OF MANUFACTURE EN 1092-2 DRILLING FLANGES MATERIALS BODY CAST IRON EN 1561 (OPT. EN GJS-400-15 EN 1563) CORROSION PROTECTION COATED INSIDE-OUTSIDE FIG.650 (FBE) EPOXY 300 MICRONS RAL 5005 FIG.650IRR (FBE) EPOXY 200 MICRONS RAL 7016 CERTIFIATES D.M. ...
Volumetric flow rate: 0.6 m³/h - 6 m³/h
Process temperature: -40 °C - 60 °C
Process pressure: 9.8 bar
... installation. At the same time, the flowmeter also has a small size and easy installation. This product is suitable for 10L / min flow rate or more models. when less than 10L / min flow choice the ...
... • Mobile compressed air measurement in front of single machines / plants • Flow measurement of process gases like e. g. nitrogen, CO2, oxygen, argon, nitrous oxide • Flow measurement at nitrogen generators • High ...
Precision: 0.5 %
... The VERIS Accelabar® is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter. It ...
Armstrong International, Inc.
Volumetric flow rate: 2 l/h - 100 l/h
Process temperature: 150 °C
Process pressure: 34, 15 bar
... For very small flow rates Measurement according to the oval gear principle For thin-bodied up to viscous liquids Low friction resistance Very precise dosing possible High resistance Wide range of viscosities can be covered Can ...
ALPHADYNAMIC PUMPS (UK) LTD
Volumetric flow rate: 50, 25, 8, 5 m³/min
... number of moving parts and the use of high quality components. Depending on the treated products and required flows, there are two types of flow measurers: the tubular version and the standard version. • The tubular ...
Volumetric flow rate: 35 l/min
Precision: 0.5 %
... grease volume is displayed. Ideal for controlling the filling of Lube-Shuttle®-cartridges resettable with LCD Display maximum flow rate 35 l/min., 2 displays (totaliser and resettable display of dispense), accuracy +/- 0,5% calibratable, ...
Volumetric flow rate: 15 l/min - 37.5 l/min
Process pressure: 12 bar
... The ZSJZ series water flow inductor is mainly applied in the sprinkler system. It is the flowing of water that to drive the blade and make the microswitch work by drive group. Thus the flow signal will be switched to ...
... Intelligent Vortex Flowmeter Vortex flow-meter, a speed type flow meter, is widely used internationally for the implementation of measuring, detecting and controlling of liquid (such ...
... It measures the quantity in litres of liquid passing through it. It works with flow rates from 10 to 90 lt/min and a maximum pressure of 3.5 bar. It displays the total liters up to 999999 liters and the partial liters up to 999 liters ...
... Pulse-Emitting Flowmeter/ Flow Indicator/Discharge Amount Checker Pulse-emitting flow meter A flow meter that does not require electric power. Combining this accessory with a TACMINA ...
... simultaneously: •Mass flow rate & total mass •Volumetric flow rate & total volume •Density •Solids (or slurry, solution) concentration •Temperature Measurement Principle Fluid flows ...
Steam Equipments
Mass flow rate: 2.5 t/h - 800 t/h
Process temperature: -20 °C - 70 °C
Precision: 1 %
... The D12 Punchplate Flowmeter is designed to measure mass flow and total accumulation of free-falling bulk material, providing a cost-effective, high-precision measurement method for the measurement of dry solid particle ...