I/O
The ARD Series comprises of remote I/O module. It is integrated with different functions including its automatic communication speed identification and network voltage monitoring duties. A noise resistance and an extensive ...
Autonics
DeviceNet Analog Remote I/O (Terminal Block Type) The ARD-A series analog remote I/O units provide input/output expansion and communication for various devices using DeviceNet protocols. The ARD-A ...
Autonics
... RTU Digital Remote I/O (Sensor Connector Type) The ARM series digital remote I/O units provide input and output expansion for PCs, PLCs, and Autonics logic panels using standard Modbus RTU protocols. ...
Autonics
... ServerSave time and wiring cost with peer-to-peer communicationSupports SNMPv1/v2c/v3Friendly configuration via web browserSimplify I/O management with MXIO library for Windows or Linux platformsWide operating temperature ...
Moxa Europe
Programmable analog output modules with 2 outputs for FRER Network Analyzers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up to 12 analogue outputs (using up ...
Programmable analog output modules with 4 outputs for FRER Network Analysers The M52U... modules with 2 or 4 analogue outputs allow, when connected to a FRER multifunctional analyser, to generate up to 12 analogue outputs (using up ...
The Z-D-IN is used to interface 5 digital signals (PUSH BUTTON, LIMIT SWITCH, REMOTE, CONTROL SWITCH, RELAIS etc.) with all of control systems which are able to communicate by the protocol MODBUS RTU through the RS485 serial interface. ...
SENECA | Automation Interfaces
The Z-D-OUT (hw.1with micro USB port on the front panel) is used to drive N.5 SPST relays from all of the control systems which are able to communicate with the transmission protocol MODBUS RTU through the RS485 serial interface. The ...
SENECA | Automation Interfaces
... other circuits) Input: - 5-CH reed, proximity, pnp, npn, contact etc. Output: - 2-CH relay 5 A, 250 Vac Operating mode: - I/O slave, time based control logic Protocol: - ModBUS RTU slave
SENECA | Automation Interfaces
... we also offer FOX I/O modules for signal processing of 2-16 channels and special functions such as pulse width modulation. This ensures that you always have the right I/O modules for every application. The ...
TR-Electronic GmbH
... we also offer FOX I/O modules for signal processing of 2-16 channels and special functions such as pulse width modulation. This ensures that you always have the right I/O modules for every application. The ...
TR-Electronic GmbH
... we also offer FOX I/O modules for signal processing of 2-16 channels and special functions such as pulse width modulation. This ensures that you always have the right I/O modules for every application. The ...
TR-Electronic GmbH
4-Port x4 PCIe interface to support a total bandwidth of 1GB/s Supports four (PoE4) independent GigE Ports Compliant with IEEE 802.3af Single maximum power consumption 23.5W Internal DC 12V Power Input External DC 19-36V Power Input
Multi I/O is a device that integrates UPS into a control system using fully configurable input and output relay signals. It can be used to connect two devices to a single UPS serial communication port. It can be used ...
Cost-optimized CANopen-slave-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication of the master control unit takes place via CANopen or a layer 2 protocol. The ESX.iox fulfils the safety ...
(STW) Sensor-Technik Wiedemann GmbH
The ESX.3ios is a CAN-I/O module for the extension of the inputs/outputs of a master control unit via CAN. The communication with the master control unit takes place via CANopen, CANopen Safety, the STW protocol ECeS ...
(STW) Sensor-Technik Wiedemann GmbH
With the ESX.mbc, we present a new CAN-J1939 module especially for the agricultural and construction machine sector, to control electric motors and actuators in a performance range of up to 200 W. It provides four fast PWM half bridges ...
(STW) Sensor-Technik Wiedemann GmbH
The PCI-9524 is a robust, multi-purpose module designed for turnkey material test systems (MTS). Equipped with four strain gauge-based transducer input channels, four general purpose analog input channels, and a 3-axis motion controller, ...
ADLINK TECHNOLOGY
The Fieldbus technology is suitable with Schlegel control units particularly for operations utilizing a big number of control units and pilot lights to be connected to the fieldbus with little wiring. The choice to network the Schlegel ...
Digital I/O module • 8 digital I/Os • Input 24 V, output 24 V / 0.5 A • Power supply via InRailBus or individual supply via COMBICON connector EtherCAT Interface •100BASE-TX ...
esd electronics gmbh
CANopen module with 8 digital I/Os • Inputs 24 V • Outputs 24 V/1 A • Input/output programmable CANopen According to CiA® Standards • CiA 301 CANopen application layer • CiA 401 generic I/O-modules 32 ...
esd electronics gmbh
CANopen module with 4 analog Inputs • Resolution: Up to 20 bits • Programmable input voltage range: ±10V • Easy control cabinet wiring due to 3-lead connection • CANopen profiles according to CiA® specification CiA ...
esd electronics gmbh
Up to PLd in accordance with EN ISO 13849-1 and SIL2 in accordance with IEC 61508 Screwless terminals for easy installation Status diagnostics via control outputs and LEDs Number of sensors can be increased to 4 per ...
... DAQ board with 8 digital I/O and two 16-bit analog outputs PCI-based 16-channel, 12-bit, 200 kS/s DAQ board with 32 digital I/O and two 12-bit analog outputs PCI-based 64-channel, 16-bit, 100 kS/s DAQ ...
Measurement Computing
The digital input module stores all measured data on an event basis and sends it to the database via Ethernet. The minimum pulse time is 100 ms. Should the connection be lost, the module stores the data intermediately to protect data ...
The digital output module serves to display information, issue alarms and control events. The relays can be interrogated or set via Modbus TCP or the RMS software. It is possible to define the conditions in the RMS software and to actuate ...
... distances of up to 10km for the 805U and 20 miles for the 905U are achievable. • Point-to-point digital and/or analogue I/O transfer • Easy to use - no configuration necessary • Secure data encryption • Intelligent ...
MTL INSTRUMENT
8 digital inputs 4 test outputs (for short-circuits monitoring) * MI16 - 16 digital inputs 4 test outputs (for short-circuits monitoring) MI12T8 - Input module with test unit * 12 digital inputs * 8 test outputs (for short-circuits ...
REER
2 pairs OSSD Cat. 4 safety outputs (PNP 400 mA) 2 inputs for Start/Restart interlock and EDM 2 status outputs (PNP 100 mA) * MO4 4 pairs OSSD Cat. 4 safety outputs (PNP 400 mA) 4 inputs for Start/Restart interlock and EDM 4 status ...
REER
MI8O2 - Input/Output units * 8 digital inputs * 2 inputs for Start/Restart interlock and external device monitoring (EDM) * 2 pairs OSSD safety outputs (PNP 400 mA) * 2 status outputs (PNP 100 mA) * 4 test outputs MI8O4 - Input/Output ...
REER
... completely isolated from the CANbus. P317 modules may be mixed on the same bus, with other types in the Trio CAN I/O range. The Trio CANbus I/O expansion can considerably reduce machine wirin
Trio Motion Technology
... Modules can be slave stations in LonWorks network consisting of Lonworks compliant products The node can communicate I/O data with other nodes in a distributed network Transmit/receive data quantity can be ...
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
>16DI/DO configurable >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
> 16DO >Support: Profinet, Ethernet/IP, EtherCAT, CC Link IEF Basic protocol fieldbus interface >Protection class: IP 67 (when correctly connected) >Shell material: Nickel plated Gd Zn alloy
Fuyansheng Electronic (Fujian) Co., Ltd.
NXI-5100 series high density programmable resistance card programmable Rresistor module NXI-5100 supports LAN bus control. Its optional range of resistance is 0Ω~11.11MΩ. Resistance accuracy can be up to 0.1%. For different applications, ...
Expansion connector: 2 PCIe x1 Interface: PCIe x1 gold finger/ PCIe connector (36 pin) (opt.) Security: Security-ROM, Intrusion detection (8 doors) Voltage watcher: Voltage monitoring and warning via MCU
DFI
Port: 1 RJ45/2 RJ45 Interface: PCIe x1 Form Factor: M.2 B-M key 22mm x 42mm (0.87" x 1.65")
DFI
Port: 1 RJ45/2 RJ45 Interface: PCIe x1 Form Factor: M.2 B-M key 22mm x 42mm (0.87" x 1.65")
DFI
The APM series modules provides easy installation and maintenance efficiency for monitoring process signals, such as temperature, voltage and current. With the ability to connect up to 31 modules, the APM Series features both standar ...
The APM series modules provides easy installation and maintenance efficiency for monitoring process signals, such as temperature, voltage and current. With the ability to connect up to 31 modules, the APM Series features both standar ...
The APM series modules provides easy installation and maintenance efficiency for monitoring process signals, such as temperature, voltage and current. With the ability to connect up to 31 modules, the APM Series features both standar ...
SIL 3 SWITCH/PROXIMITY DETECTOR REPEATER, RELAY OUTPUT DESCRIPTION The dual channel Switch/Proximity Detector Repeater, D5030D module, is a unit suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed. 2) in ...
GM International srl
... ) modules. All modules are compact in size and will work with Modbus as well as other available protocols. The IOS serial Remote I/O is ideal in applications where DIN rail space is limited, as the ...
... remote I/O system, it linked a local area network designed to connect controllers to remote I/O chassis and replacement of discrete wirings by fieldbus or industrial Ethernet communication. MIOS supports ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining