- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- IP66 flow meter
IP66 flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Process pressure: 40, 160 bar
Precision: 0.5 %
... 150)
Lining: PFA
Ambient temperature: Up to 65 °C
Protection type:
IP
66/
IP67
Outputs: Analog output (4 to 20 mA) with HART and pulse/frequency/status
Display:
LCD display, ...
Process temperature: -5 °C - 90 °C
Process pressure: 10 bar - 40 bar
Precision: 0.5 %
... rubber
Ambient temperature: Up to 65 °C
Protection type:
IP
66/
IP67 (
IP68 for remote version)
Outputs: Analog (4–20 mA) with HART; pulse / frequency / status outputs
Display: ...
Process temperature: -40 °C - 140 °C
Process pressure: 0 bar - 5 bar
Precision: 0.5 %
... >Ambient temperature: up to 65 °C
Protection rating:
IP
66/
IP67 (
IP69 for stainless steel housing)
Outputs: analog 4–20 mA with HART plus pulse/frequency/status
Display: white ...
Process temperature: -55 °C - 280 °C
Precision: 0.5 %
... internal flow and temperature. FSS450 is ideal for direct mass flow or standard flow of gases and liquids or direct mass and energy flow on saturated and overheated steam. Swirl ...
Process temperature: -200 °C - 120 °C
Precision: 0.25 %
... The Sentinel LNG ultrasonic custody transfer liquid flow meter extends cryogenic applications to -200 C. Like other Sentinel meters it is reliable, robust and cost effective. With no moving parts, a robust ...
Panametrics
Volumetric flow rate: 20 m³/h - 12,022 m³/h
Process temperature: -40 °C - 140 °C
Precision: 0.12 %
... the Panametrics line of ultrasonic flow meters for high-accuracy metering applications. Used primarily for measuring hydrocarbon liquids and water for critical use. the eight-path design of the LCT8 enables the meter ...
Panametrics
Process temperature: -40 °C - 150 °C
Precision: 1, 2, 0.5 %
Repeatibility: 0.2 %
... AquaTrans AT600 is a liquid clamp-on flow meter designed to be accurate, durable and cost-effective. Rugged and reliable, this meter will remain fixed to your pipe for years to come. Applications The ...
Panametrics
Process temperature: -20 °C - 60 °C
Repeatibility: 0.1 %
... ATEX ELECTROMAGNETIC FLOWMETER M3000/4000
RELIABLE FLOW MEASUREMENT FOR HAZARDOUS AREAS
The Fuji Electric ATEX electromagnetic
flowmeter M3000/4000 is designed ...
FUJI ELECTRIC France
Process temperature: -273 °C - 200 °C
Precision: 1 %
... FIXED ULTRASONIC
FLOWMETER TIME DELTA-C – CONVERTER – FSV
IP
66
NON-INTRUSIVE FLOW MEASUREMENT TO IMPROVE INDUSTRIAL PROCESS RELIABILITY
The fixed ultrasonic ...
FUJI ELECTRIC France
Process temperature: -10 °C - 60 °C
Precision: 2 %
... ULTRASONIC
FLOWMETER FOR NITROGEN GAS – FWD-N
ACCURATE AND RELIABLE NITROGEN FLOW MEASUREMENT FOR YOUR INDUSTRIAL PROCESSES
The FWD-N in-line ultrasonic
flowmeter is ...
FUJI ELECTRIC France
Volumetric flow rate: 10 l/h - 2,800,000 l/h
Process temperature: -200 °C - 400 °C
... 752°F; max. 1000 barg / 14500 psig The H250 M40 is the standard variable area (VA) flowmeter for the process and OEM industry. The VA meter combines mechanical flow measurement of liquids or gases ...
Volumetric flow rate: 1.6 l/h - 8,000 l/h
Process temperature: -80 °C - 150 °C
Process pressure: 0 bar - 130 bar
... Variable area flowmeter for advanced low liquid and gas flows* Mechanical or with electronic indicator (4…20 mA/HART®) * Sturdy metal design: stainless steel or alloy * Thread: G1⁄4, 1⁄4 NPT; others * ...
Volumetric flow rate: 1.6 l/h - 4,800 l/h
Process temperature: -40 °C - 200 °C
Process pressure: 0 bar - 130 bar
... max. 220 barg / 3190 psig The DK32/34 is a variable area (VA) flowmeter for measuring low flow rates of liquids and gases. The tried and tested meter is particularly suitable for flow ...
Process temperature: -20 °C - 180 °C
Precision: 0.3, 1, 3 %
Repeatibility: 0.15 %
... With the platform FLUXUS 532, FLEXIM has once again set a new standard. Compact and extremely cost-efficient flow transmitters for all important applications in the manufacturing industry, for food, pharmaceutical and building technology. ...
EMERSON - FLEXIM
Process temperature: -40 °C - 600 °C
... substantially improved measurement algorithms make the FLUXUS F721 liquid flow meter a state-of-the-art measuring solution even for the most challenging applications. The meter adapts itself automatically ...
EMERSON - FLEXIM
Process temperature: -40 °C - 200 °C
Precision: 1 %
... sophisticated and highly accurate non-intrusive flow meter combines very precise ultrasonic flow and sound speed measurement with advanced calculation features and diagnostics. The H721’s nonintrusive ...
EMERSON - FLEXIM
Mass flow rate: 0 kg/h - 2,200,000 kg/h
Process temperature: -196 °C - 240 °C
Process pressure: 100 bar
... process safety – immune to fluctuating and harsh environments Fewer process measuring points – multivariable measurement ( flow, density, temperature) Space-saving installation – no in-/outlet run needs Full access to process ...
Endress+Hauser AG
... SMARTLINK® METER is a highly accurate and repeatable mass flow meter well suited for monitoring fuel and air. The meter is built with a rugged NEMA 4X ( IP 66) ...
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the ...
Pulsar Measurement
Process temperature: -40 °C - 60 °C
... gas flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With its multipath ...
Process temperature: 150 °C
Process pressure: 150 bar
... reagent in flue gas treatment and transport lines with very low material concentration Electrodynamic flow sensor for measurement of low flow rates from 0 to 100 kg/h. For pipe diameters up to 1 m. Ideally used ...
Process temperature: -10 °C - 60 °C
Precision: 3, 0.5, 1 %
Repeatibility: 0.15 %
... Description The ultrasonic flow meter clamp-on for fixed installation IFX-F100, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...
Process temperature: -40 °C - 150 °C
Precision: 1 %
Repeatibility: 0.25 %
... Description The portable clamp-on flow meter for fixed installation IFX-f161, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...
Process temperature: -18 °C - 121 °C
Process pressure: 34, 10 bar
Precision: 0.5, 1, 2 %
... compact, low cost solution for accurate, repeatable flow measurement of biogas, digester gas, landfill gas, methane and natural gas as well as air, compressed air or nitrogen. This insertion-style flow meter ...
FCI Fluid Components International
Volumetric flow rate: 5.13 m³/h - 951.57 m³/h
Process temperature: -18 °C - 121 °C
Process pressure: 16.5, 41 bar
... The ST75 Series thermal flow meters are a compact, low cost solution for accurate, repeatable direct mass flow measurement of air and gases. These in-line (spool-piece) style flow meters ...
FCI Fluid Components International
Volumetric flow rate: 0.1667 l/min - 23.75 l/min
Process temperature: -40 °C - 454 °C
Process pressure: 70, 10 bar
... dispersion technology air/gas flow meter that combines ultra-reliable, feature-rich electronics, and FCI innovations such as Adaptive Sensing Technology™ (AST™) with the industry's most extensive selection of application-matched ...
FCI Fluid Components International
Volumetric flow rate: 4 l/h - 200,000 l/h
Process temperature: -50 °C - 200 °C
Precision: 2 %
... Technical Data BF300E for high flows of gas, liquid and steam Case Material: SS316 Body wetted parts: SS316, Others on request. Indication via magnetic coupling (no sealed) Scales calibrated: in l/h, m3/h, kg/h, %, etc.. Flow ...
Golden Mountain Enterprise
Volumetric flow rate: 4 l/h - 15,000 l/h
Process temperature: -30 °C - 100 °C
Precision: 5, 2 %
... Data BPF300 for high flows of gas and liquid Case material: SS316; Aluminum alloy available Body Wetted Parts Material: in PVC, CPVC, PVDF indication via magnetic coupling (no sealed) Scales calibrated: in l/h, m3/h, kg/h, %, etc. Flow ...
Golden Mountain Enterprise
Volumetric flow rate: 30 l/h - 120,000 l/h
Process temperature: -50 °C - 400 °C
... 250mm standard for size 1/4"~4", 300mm standard for size 5~10"; Special length is on request Protection Class: Weather Proof IP 66 / IP68 or Explosion proof available Accuracy: ±2.5%F.S (±2.0%FS option) Max. ...
Golden Mountain Enterprise
... transmitters of DA2000er series: • Large analog display (270 °) – Scale length 250 mm • Scale in m³ / h • Different limit indicator • Analog outputs 0 … 10 V or 4 … 20 mA possible (linear or square root) • Combination with a pressure ...
Volumetric flow rate: 0 l/min - 1.5 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 100 bar
... ES- FLOW® are Volumetric Liquid Flow Meters for very low flow ranges. The instruments operate on a innovative measuring principle, using ultrasound in a very small, straight tube. A wide ...
Process temperature: 0 °C - 60 °C
... series?
Unlike traditional
meters, this system combines a dual measurement principle (pressure and velocity) in a single compact body, ensuring reliable data for calculating instantaneous and total
flow rate.
Main ...
Process temperature: -35 °C - 200 °C
Precision: 0.5, 2 %
... Doppler flowmeter for accurate volumetric flow measurement in closed pipes conveying dirty liquids, slurries or air-entrained fluids. Using Doppler backscatter from suspended particles or bubbles, it delivers reliable ...
Process temperature: -40 °C - 85 °C
Precision: 1 %
... TRANSMISSION IN COMPACT Housing The RQ-30 ADMS is an all-in-one discharge measurement System. It contains the non-contact flow velocity and water level sensors of the RQ- 30 and applies the same algorithms and model to calculate the ...
Process temperature: 0 °C - 50 °C
... for big volumes of water. It is used a fluorescent material as tracer. When using the tracer in sewage water most often a continuous insertion of a known amount of tracer is done. Two optical fluorescence probes automatically determine ...
Volumetric flow rate: 0.06 m³/h - 36 m³/h
Process temperature: -40 °C - 60 °C
Process pressure: 50,000 Pa - 300,000 Pa
... MFHD series of meters are designed for fuel cylinder management and can be used for natural gas metering as well. Its compact size covers residential fuel application ranges and opts to output fuel thermal values. The meter ...
Volumetric flow rate: 0.1 m³/h - 160 m³/h
Process temperature: -20 °C - 65 °C
Process pressure: 0.2 MPa
... The meter is fully operated with battery. It is the 3rd generation of commercial gas meters for city gas applications. The meter is ATEX certified. It has also be used in the industrial burner fuel efficiency ...
Volumetric flow rate: 0 l/min - 4,000 l/min
Process temperature: -10 °C - 55 °C
Process pressure: 0.8 MPa
... independent (limited gases) mass flow with super high precision. MF5900 series mass flow meters are designed for general purpose flow metering and control ctechnology and smart electronic ...
Volumetric flow rate: 0.01 us gal/min - 53,779 us gal/min
Process temperature: 0 °F - 248 °F
Process pressure: 0 psi - 150 psi
... Electromagnetic flow meter is virtually unaffected by density, temperature, pressure and viscosity changes, making it an accurate and reliable long-term metering solution. Innovative Design. Enhanced Performance. The ...
Volumetric flow rate: 0 m³/h - 33,629 m³/h
Process temperature: -200 °C - 350 °C
... U-shaped dual sensors maximize accuracy Flow rate turndown up to 200:1 Suitable for liquids and gases Sensor sizes from <1mm through 10” Ability to measure rates from 0-0.032 GPH to 0-423,000 BPD Flow ...
Mass flow rate: 81 kg/h - 1,324,739 kg/h
Volumetric flow rate: 5.2 m³/h - 85,371 m³/h
Process temperature: 0 °C - 400 °C
... The KOBOLD Vortex Flowmeter DVE utilises three primary sensing elements: a vortex shedding velocity sensor, a RTD temperature sensor and a solid-state pressure transducer to measure the mass flow rate of gases, liquids ...
KOBOLD Messring GmbH
Mass flow rate: 0 kg/min - 200 kg/min
Process temperature: -196 °C - 400 °C
Process pressure: 0 bar - 882 bar
... The RHM 15 is an all-purpose meter suitable for liquid processing plants. A wide application flow range capability allows for commonality of installation across numerous lines – a real benefit to owners and operators. Materials: ...
Rheonik Messtechnik GmbH
Volumetric flow rate: 0.5 l/h - 550 l/h
Process temperature: -20 °C - 120 °C
Process pressure: 34, 15 bar
... The Micropulse range of positive displacement flowmeters offer a high level of accuracy and repeatability. These precision meters can be used for flowrate measurement, in flow monitoring control applications ...
Filton Process Control Engineering
Volumetric flow rate: 0 l/min - 36,000 l/min
Process temperature: -14 °C - 65 °C
Process pressure: 310, 100, 70 bar
... proven SLA5800 family of meters and controllers. A specially engineered NEMA4X/ IP 66 enclosure protects our advanced digital electronics and ensures stable, accurate measurement and control of your process-critical ...
Brooks Instrument
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group