- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- IP68 flow meter
IP68 flow meters
Volumetric flow rate: 0.9 m³/h - 6,627 m³/h
... ultrasonic level transmitter - Level transmitter can be used for all flume types - Displaying of flow measurement and average or total flow - Certification of measurement Applications - ...
Process temperature: -40 °C - 600 °C
... substantially improved measurement algorithms make the FLUXUS F721 liquid flow meter a state-of-the-art measuring solution even for the most challenging applications. The meter adapts ...
FLEXIM Flexible Industriemesstechnik GmbH
Process temperature: -190 °C - 650 °C
Precision: 1.6, 1.2, 0.5 %
Functional Safety approved Flowmeter The FLUXUS non-invasive ultrasonic flow meters have always been the first choice when it comes to maintaining accurate measurements in harsh conditions ...
FLEXIM Flexible Industriemesstechnik GmbH
Process temperature: -40 °C - 130 °C
Precision: 1 %
Repeatibility: 0.15 %
... other meter technologies, such as magnetive inductive meters, can increase so dramatically in the low flow range, that they are unsuitable for monitoring minimum night flows. ...
FLEXIM Flexible Industriemesstechnik GmbH
Process temperature: -10 °C - 60 °C
Precision: 0.2 %
... entire sensor body at equal area, measure and report the average flow rate over the full diameter of the pipe. The specific design of the multi-electrode sensor compensates for variable flow profiles, ...
Flow-Tronic S.A.
Process temperature: -20 °C - 50 °C
Open Channel Ultrasonic Digital Doppler Flow Meter Sensor The BELUGA is the newest ultrasonic Doppler area/velocity flow meter sensor for open channel flow ...
Flow-Tronic S.A.
Process temperature: -30 °C - 70 °C
... non-contact RADAR area/ velocity flow meter specially designed for rivers and large channels. The PHOENIX is mounted above the water surface and measures the flow velocity at the ...
Flow-Tronic S.A.
Process temperature: -10 °C - 80 °C
Precision: 1, 2 %
... Introduction E5E Ultrasonic Energy Meter support cold&heat measurement,using advanced modular design,independent menu operation and LCD backlight display E5E has the high accuracy clamp on/insertion ...
Gentos
Process temperature: -10 °C - 80 °C
Precision: 1 %
... flowmeter. Introduction D116 Series Ultrasonic Flowmeter is a state-of-the-art universal transit-time flowmeter designed using FPGA chip and low-voltage broadband pulse transmission. The flowmeter ...
Gentos
Process temperature: -40 °C - 80 °C
Precision: 0.5 %
Repeatibility: 0.1 %
Ultrasonic flow meters that use transit-time methods to measure flow. Introduction D118i is an advanced flow meter, which applies our patented ...
Gentos
Volumetric flow rate: 0.9 m³/h - 9,048 m³/h
Process temperature: -10 °C - 85 °C
Precision: 0.5, 0.2 %
... able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). Reverse Flow - Allows measure and totalization of reverse flow Output ...
SGM LEKTRA
Volumetric flow rate: 0.1 m³/h - 18,000 m³/h
Process temperature: -40 °C - 100 °C
Precision: 0.5 %
Flow measurement for conductive liquids Measurement range DN10 ÷ 800 GPRS data transmission Battery powered, 6 years autonomy; 12÷24Vdc Analog, impulsive and MODBUS RTU outputs Parameter programming via ...
SGM LEKTRA
Volumetric flow rate: 1 m³/h - 9,048 m³/h
Process temperature: -40 °C - 85 °C
Precision: 0.5 %
... LEKTRA presents a new type of electromagnetic flowmeter with plastic sensors: RKmag. Because of its particular inner shape the mounting of the unit requires no straight pipe lengths before and after the meter. ...
SGM LEKTRA
Process temperature: 0 °C - 250 °C
Precision: 2 %
The DOPPLER flowmeters are designed to measure the volumetric flow in closed and full pipes. It consists of two sensors an emitter and an ultrasonic receiver. The emitted waves are transmitted by the ...
Sensotec Instruments
Process temperature: -10 °C - 80 °C
Precision: 1 %
Repeatibility: 0.2 %
... 300 to 3000 mm). Available outputs 4-20 mA, OCT and relay. RS485 communication. Magnetic sensors with IP 68 protection applicable in pipes of homogeneous materials.
Sensotec Instruments
Process temperature: 50 °C
... performance fixed installation Area Velocity flowmeter with extended features for open channel, part-filled pipe and river application. Dimensions: 166x161 x103 mm; Wall mounting ABS enclosure; Protection class: IP ...
Sensotec Instruments
Volumetric flow rate: 1 m³/h - 4 m³/h
Process temperature: 50 °C
Process pressure: 0.3 bar - 16 bar
... starting flow and is permitted for all installation positions. The meter is equipped with an 8-digit glass/copper register (IP68) and a modulator disc. This enables ...
Process temperature: -40 °C - 60 °C
... Collection system flow monitoring Industrial pretreatment flow monitoring Waste Water Treatment Plant flow measurement Standard Features: Class 1, Div I, Zone 0, ATEX category 1G ...
Teledyne Isco
... diagnostic functions support users and provide guidance for setting up a flow measurement with best possible accuracy. Pipe size: 0.08 m … 3 m Pipe wall thickness 1 mm … 60 mm Flow velocity: ± 0 ...
Process temperature: -25 °C - 250 °C
Process pressure: 1 MPa - 4 MPa
Precision: 0.5, 1 %
... by convertor, you can see the instantaneous flow, cumulative flow, output pulse, analog current and other signals for the measurement and control of fluid flow. It is suitable for the ...
Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
Process temperature: -10 °C - 120 °C
Process pressure: 0.6 MPa - 4 MPa
Precision: 0.5 %
... coil, the following electromotive E is generated in proportion to flow speed v: Where: E-Induced electromotive force K-Meter constant B-Magnetic induction density V-Average flow ...
Supmea Automation
Process temperature: -70 °C - 380 °C
Precision: 1 %
... interface of the large graphical display is easy to use even by inexperienced users. With the new quick setup option, your flow measurement can be set up in less than a minute. Online help-texts make the use of the printed ...
Volumetric flow rate: 0.3 m³/h - 500 m³/h
Process temperature: -25 °C - 55 °C
Process pressure: 16 bar
● Diameter: DN50-DN200 ● Accuracy class: Class 2 ● Ultrasonic measurement, high precision measurement, wide range ratio, strong anti-interference ability. ● Micro power, built-in high-capacity lithium battery, battery life is more ...
Shandong Hetong Information Technology Co.,Ltd.
Process temperature: -40 °C - 160 °C
Precision: 1, 1.5, 0.5, 0.2 %
... transit-time ultrasonic flowmeter with clamp-on sensors for non-invasive liquid measurement. Based on microprocessor and programmable flow measurement techniques the process flow can ...
ALIA GROUP INC
Process temperature: -25 °C - 180 °C
Process pressure: 40, 6, 10, 16 bar
Precision: 0.5, 1 %
FEEJOY Electromagnetic Flow Meter is a mag flow meter or magnetic flow meter which uses an electromagnetic coil to generates a magnetic ...
Feejoy Technology
Volumetric flow rate: 0.2 m³/h - 400,000 m³/h
Process temperature: -30 °C - 160 °C
Portable Time Transit Ultrasonic Flowmeter Kit IP66 wall mounting enclosure Insertion or clamp on transducers Simultaneous display of flow rate and cumaltive flow ...
LTH Electronics Ltd
Process temperature: -20 °C - 60 °C
... CHANNEL FLOW METERS. THESE COMES WITH ULTRASOUND OR HYDROSTATIC SENSORS FOR OPEN CHANNELS AND PARTIALLY FILLED PIPES. THE CURRENT GENERATION OF OPEN CHANNEL FLOW METERS ...
MJK Automation
Process temperature: 0 °C - 50 °C
Process pressure: 16 bar
... measuring principle) • Robust water flow meter • Accurate meter measurements • Horizontal and vertical installation • Nominal diameter DN 40 • Protection class IP68 • ...
INTEGRA Metering AG
Process temperature: -30 °C - 160 °C
... series flow meter usually is used to long-term measure at field. It's easy to use and easy to repairing without cut off the piple,without turn off the fluid.Both the sensor and the host can be installed on ...
Xian Kacise Optronics Co., Ltd.
Precision: 0.2 %
... electromagnetic flowmeter for DMA (District Metered Area) • Invest smartly through ‘single box’ DMA solution – combining flow, pressure and data-logging • Have greatest confidence in your billing based ...
Shanghai Powerbuilder Automation Technology Co. Ltd
Volumetric flow rate: 1 l/min - 350 l/min
Process temperature: -20 °C - 60 °C
Precision: 2.5, 5 %
To capture gas flows away from the source of the leakage rate, measured by sampling at high speed, thus there is a dilution of the surrounding air. Accurate sample flow rate and natural gas concentration ...
Process temperature: -20 °C - 120 °C
Process pressure: 6 bar - 320 bar
Precision: 0.3, 0.5, 1 %
... stream *Turndown Ratio: The turndown ratio can reach to 1: 100 *Enclosure: For DN15-DN1200 is IP68 *High Intelligence: Back light English/Chinese LCD display, Menu setting control,
Volumetric flow rate: 0 ft³/s - 16 ft³/s
Process temperature: -40 °C - 80 °C
Precision: 1 %
... and also the clear, user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly and yearly totalized flow. Parallel operation of positive, negative ...
Soway Tech Limited
Process temperature: -180 °C - 650 °C
Precision: 1, 0.5, 3 %
... Demineralized water Cold – / Heat exchangers Clean Rooms Temporary replacement inline flowmeters Verification inline flowmeters Leakage- / Blockage testing Flow measuring Pump ...
U-F-M b.v.
Volumetric flow rate: 2.5 m³/h - 1,000 m³/h
Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 16 bar
No straight length needed, installation all angles No alteration of the accuracy minimum starting flow = 1/3 of the traditional water meter Water temperature detection, low temperature alarm No moving ...
Prisma Instruments
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining