- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- IP68 flow meter
IP68 flow meters
Volumetric flow rate: max 300.0 l/s
Process temperature: 0 °C - 40 °C
Process pressure: 0 bar - 20 bar
... AQ FLOW SENSOR – Precise. Robust. Truly Real-Time. The AQ FLOW SENSOR is a patented insertion flowmeter, offering a smart alternative to ultrasonic and inductive devices. It enables real-time flow measurement ...
Volumetric flow rate: max 300.0 l/s
Process temperature: 0 °C - 40 °C
Process pressure: 0 bar - 20 bar
... Hydrant Flow Sensor – True-Born Underground Integration The AQ IoT Hydrant Flow Sensor is a patented, in-house innovation designed for true-born underground hydrant integration. It offers a simple and cost-effective ...
Process pressure: 1.6, 2.5, 4 MPa
Precision: 5 %
... Electromagnetic flowmeter type PEM-500 is applicable to the measurement of flow of the liquids with minimum conductivity of 5ěS/cm. Device measures flow and volume of liquids in both directions of ...
Process temperature: 0 °F - 302 °F
Process pressure: 0 psi - 232 psi
... M5000 is a battery-powered electromagnetic flow meter with a very high accuracy even at very low flows. The excellent repeatability as well as the above-average battery life makes this innovative water ...
Process pressure: 0.6 mbar - 4 mbar
Precision: 0.2 %
... supply IP65 protection class Robust housing Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs General Features Excellent small ...
Volumetric flow rate: 0.1 m³/h - 40,715 m³/h
Process temperature: -20 °C - 150 °C
Process pressure: 0 bar - 40 bar
... will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consist of an isolated lined tube, through which a conductive liquid flows, ...
Process temperature: 0 °C - 250 °C
Precision: 2 %
... The DOPPLER flowmeters are designed to measure the volumetric flow in closed and full pipes. It consists of two sensors an emitter and an ultrasonic receiver. The emitted waves are transmitted by the transmitting gel ...
Sensotec Instruments
Volumetric flow rate: 0.9 m³/h - 6,627 m³/h
... ultrasonic level transmitter - Level transmitter can be used for all flume types - Displaying of flow measurement and average or total flow - Certification of measurement Applications - For open channels, ...
Process temperature: -40 °C - 60 °C
... Collection system flow monitoring Industrial pretreatment flow monitoring Waste Water Treatment Plant flow measurement Standard Features: Class 1, Div I, Zone 0, ATEX category 1G approval Rugged, ...
Teledyne Isco
... diagnostic functions support users and provide guidance for setting up a flow measurement with best possible accuracy. Pipe size: 0.08 m … 3 m Pipe wall thickness 1 mm … 60 mm Flow velocity: ± 0 … 20 m/s bi-directional Maintenance-free ...
Process temperature: -25 °C - 250 °C
Process pressure: 1 MPa - 4 MPa
Precision: 0.5, 1 %
... by convertor, you can see the instantaneous flow, cumulative flow, output pulse, analog current and other signals for the measurement and control of fluid flow. It is suitable for the conductive medium ...
Shanghai Zhaohui Pressure Apparatus Co.,Ltd.(ZHYQ)
Process temperature: -10 °C - 120 °C
Process pressure: 0.6 MPa - 4 MPa
Precision: 0.5 %
... coil, the following electromotive E is generated in proportion to flow speed v: Where: E-Induced electromotive force K- Meter constant B-Magnetic induction density V-Average flow speed in cross-section ...
Supmea Automation
Process temperature: 0 °C - 60 °C
Precision: 1 %
Repeatibility: 0.3 %
... The InnovaSonic 203 liquid flow meter is optimized for customers still looking for high performance, but needing a lower-cost, less feature-rich option for dedicated clamp-on ultrasonic metering. The 203 digital liquid ...
Sierra Instruments
Process temperature: -22 °F - 158 °F
... non-contact radar and velocity flow meter that provides accurate and reliable data while eliminating the need for field maintenance. When paired with our Atrax monitoring solution, it creates a robust real-time, wireless ...
Process pressure: 25 bar
... Ultrasonic flow meter QALCOSONIC F1 ( IP 68) is designed for the measurement of cold and hot water consumption in households and blocks of flats, as well for industrial applications. The ...
Volumetric flow rate: 0.1 m³/h - 9.5 m³/h
Process temperature: -20 °C - 130 °C
Process pressure: 0 bar - 64 bar
... The RIF100 is an electromagnetic flow meter that utilizes Faraday's principle to measure the velocity of the liquid and convert it into a signal proportional to the flow. Among its advantages are good ...
Riels Instruments
Process temperature: -25 °C - 75 °C
Process pressure: 0.5 bar - 1.5 bar
Precision: 0.2 %
COMETEC SA
Process pressure: 25 bar
... bi-directional insertion full bore flowmeter for permanent or portable use in managing water distribution systems. It is a cost effective alternative to full-bore flow meters and is ideal for use over ...
Process temperature: -20 °C - 70 °C
... This flowmeter measures accurate flow rate with a precise sensor and provides various weir and plume measurement formulas, making it easy to use according to the user's environment. Main features Open channel dedicated ...
Process pressure: 10, 16, 40 bar
... electromagnetic flow meter are based on decades of practical experiences. They are highly reliable, easy to operate and very suitable for harsh conditions. Features: - Easy to install, various process connections - ...
SMAAT TECHNIQUES SAS
Volumetric flow rate: 1.5 m³/h - 9,048 m³/h
Process temperature: -40 °C - 85 °C
Precision: 0.5, 0.2 %
... able to process signals from fluids with flow rates of up to 10m / s in both directions (bidirectional meter). Reverse Flow - Allows measure and totalization of reverse flow Output ...
SGM LEKTRA
Process temperature: -40 °C - 85 °C
... Radar Flow Velocity Transmitter is connected directly via RS485 communication interface, providing simple, reliable, cost-saving process data with remote monitoring, calibration, configuration and diagnostics capabilities. Housing in ...
Process temperature: -40 °C - 160 °C
Precision: 1 %
... Series DUS-TT-F wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies ...
Prisma Instruments
Process temperature: 0 °C - 50 °C
Process pressure: 16 bar
... measuring principle) • Robust water flow meter • Accurate meter measurements • Horizontal and vertical installation • Nominal diameter DN 40 • Protection class IP 68 • ...
INTEGRA Metering AG
Process temperature: -45 °C - 80 °C
Precision: 0.2, 0.5 %
... magnetic flow meter can reach 0.2%. 2. Wide measurement range: electromagnetic flow meter can measure the flow of various fluids, applicable to a variety of industrial ...
Process temperature: -20 °C - 60 °C
Precision: 0.4, 0.2 %
... Electronics protection - IP 68 Other features - Test of excitation coils Empty pipe detection Zero flow adjustment ...
Arkon Flow Systems
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group