Isolated amplifiers

12 companies | 40 products
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.defLight}}
{{#if product.requestButtonsVisibility.requestButtonQuestion == "ACTIVE" || product.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.defLight}}
{{#if product.requestButtonsVisibility.requestButtonQuestion == "ACTIVE" || product.requestButtonsVisibility.requestButtonWhereToBuy == "ACTIVE"}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
voltage amplifier / current / measuring / low-noise
voltage amplifier
MX1601B

Voltage: 100, 10,000, 60,000 mV
Current: 20 mA

... MX1601B measuring amplifier convinces through the 16 channels it provides and its high precision, which make it the ideal choice when it comes to complex measurement tasks in research and development. QuantumX MX1601B ...

signal amplifier / acquisition / isolated / for measuring
signal amplifier
SomatXR MX1601B-R

Voltage: 60, 10, 100 V
Current: 0 mA - 20 mA

SomatXR MX1601B-R amplifier 16 individually configurable channels for active sensors SomatXR MX1601B-R amplifier: 16 individually configurable channels for active sensors Do you want to use active ...

signal amplifier / voltage / current / instrumentation
signal amplifier
LCD20

Voltage: 0 V - 10 V
Current: 4 mA - 20 mA

... provides isolated current 4-20mA and voltage 0-10V analogue outputs and two digital inputs. Two set point relays can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC ...

signal amplifier / conditioning / digital / voltage output
signal amplifier
LCB20

Voltage: 0.5 mV - 7.8 mV

... digital signal conditioning amplifier for single or multiple load cell applications, offering very easy one-pass calibration and fast setup. PCB version of the load cell amplifier display for weighing ...

signal amplifier / analog / isolated / for strain gauge sensors
signal amplifier
IMA2DMS

Voltage: 0 V - 10 V
Current: 0 mA - 20 mA

IMA2 DMS amplifier is a complete signal processing unit for force or pressure transducers based on straingages. Most of commonly used output signals (0..5 V, 0..10 V, ±5 V, ±10 V, 0..20 mA, 4..20 mA) are available. The ...

signal amplifier / analog / isolated / transducer
signal amplifier
IMA2R

Voltage: 0 V - 10 V
Current: 0 mA - 20 mA

IMA2-R amplifiers are complete signal processing units for potentiometric transducers and convert potentiometric output signals to standardized signals. The connected sensor is powered with 5 V by default (supply voltages ...

signal amplifier / analog / isolated / for inductive and resistive sensors
signal amplifier
IMA2LVDT

Voltage: 0 V - 10 V
Current: 0 A - 20 A

IMA2 LVDT amplifiers are complete signal processing units for inductive transducers. The amplifier is preset according the ordered version and powers the connected LVDT by default. Most of commonly used ...

signal amplifier / measuring / DC / multi-channel
signal amplifier
SIQUAD DC8

Voltage: 0.01 V - 100 V
Current: 4 mA - 20 mA

Measurement amplifier plug-in unit 19" technology 3 HE / 5 TE 8-channel DC amplifier 24 bit for voltage and/or current signals, 0.01.. 100 V, 0/4..20 mA 8 isolated channels with common ...

measuring amplifier / isolated / electronic
measuring amplifier
HSI Modules

HSI, HIGH-SPEED AMPLIFIERS UP TO 2 MHZ The single channel, analog high-speed isolation amplifiers have an analog ±5 V output and provide a bandwidth up to 2 MHz. The modules plug into many DEWETRON instruments ...

load cell amplifier / voltage / current / electronic
load cell amplifier
ATM 04 ANA

Voltage: 24 V
Current: 1 A
Power: 2 W

NBC Elettronica presents ATM04 ANA load cells digital amplifier. It provides analog output (voltage/current). It has a 7mm high LED display with 7 red segments and 5 digits. Three mechanical buttons are provided with ...

voltage amplifier / measuring / acquisition / electronic
voltage amplifier
MA-U

Voltage: 10 V
Frequency: 50 kHz

... for sensor supply - DC or AC decoupled - reusable for other measuring tasks CONDITIONED TO VOLTAGE. The measuring amplifier MA-U adjusts voltage signals to the 5V input of a PC data acquisition system. To emphasize ...

power amplifying integrated circuit / operational / high-current / isolated
power amplifying integrated circuit
PA01 / PA73

Voltage: 60 V
Current: 5 A

... regulators and motor/synchro drivers. These power amplifiers are internally compensated for all gain settings. The PA01 and PA73 are a hybrid product design and are housed in an electrically isolated, ...

See the other products
Apex Precision Product
strain gauge sensor amplifier / signal / electronic / adjustable
strain gauge sensor amplifier
AME2

Voltage: 10 V
Current: 4 mA - 20 mA

The amplifier AME2 has been designed for amplifying small sensor signals of full bridge strain gauges to standardized voltage and current levels. The narrow design of the AME2 amplifier is exceptionally ...

current amplifier / isolated / IP66
current amplifier

Current: 4 mA - 20 mA

AMPBOX is a current loop amplifier for the complete range of solar radiometers. Most radiometers have no power supply, the measured radiation is used to create an output signal in the mV range and amplification is often ...

signal amplifier / switching / isolation / digital
signal amplifier
KFD-2, KFA-6

Voltage: 230, 24 V
Current: 20 mA - 23 mA
Power: 1 W

... short-circuit (LK). The input is safely isolated from the output and mains according to DIN EN 50 020. Output and mains are isolated from each other according to IEC 661140. The device is fitted with ...

signal amplifier / isolation / with relay output / isolated
signal amplifier
SEM1630

Voltage: 250 V
Current: 1 A

... Thermocouple,mV,mA Input Dual Relay Outputs 250V AC @ 1A Relay Contacts isolated from each other Galvanic Isolation Simple USB Configuration Port The SEM1630 is a DIN rail mounted trip amplifier ...