- Detection - Measurement >
- Electrical Measurements >
- Precision current sensor
Precision current sensors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 10 A
... Product Category: Current Sense Transformer Part Number: 53060C Manufacturer: Murata Manufacturing Co., Ltd. Product Details: - Current sense transformers are used for measuring alternating ...
Murata Power Solutions
Primary current: 2 mA - 15 mA
... Residual current detection options for IEC based requirements are 30mA AC & 6mA DC or 20mA AC & 6mA DC for UL requirements. It can not only detect AC ...
IVY METERING
Primary current: 3 mA - 100 mA
... Type A RCD functionality with 6mA DC leakage detection in a single unit. IEC 62955 Compliance: Meets the requirements of IEC 62955, the international standard for RCMU in EV charging stations. Enhanced DC ...
IVY METERING
Primary current: 100 A
... D129072 is a split-core current sensor with M-bus communication. Its structural design ensures fast speed load and unload under constant power, which greatly improves the construction efficiency. With M-BUS communication, ...
IVY METERING
Primary current: 50 A - 600 A
... Presentation
Open-loop Hall-effect
current
sensors with Ø21 mm opening for primary
currents from 50 to 600 A (depending on model).
Description
The MTCCO series of Hall-effect
current ...
Primary current: 0 A - 3,000 A
... Connector for connection to MEP-1 analyzer. - Precision: Class 0.5% across the entire scale. - Integration: Thanks to their opening core, the installation of current sensors is possible without disconnecting ...
Primary current: 300 A
... The DC Hall effect current sensor is a current sensor made by using the open-loop Hall effect. The primary and secondary are completely insulated. It is mostly utilized ...
Primary current: 4,000 A
... 4000 A/333 mV Ø180 mm 12 Vdc converter Rogowski loop Rogowski loops are a new generation of flexible current transformers that allow users to easily pass the product around the cable or bar, even in confined spaces. Rogowski loops ...
Primary current: 100 A - 500 A
... Hall Current Sensor is a new generation Open loop Split core current sensor based on Hall effect principle. It can accurately measure DC, AC, and pulse current as well ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 300 A - 2,000 A
... SCK18 Series is open-loop current sensor develops on hall effect principle. There is galvanic isolation between primary and secondary circuit of the sensor, it can measure DC, AC or pulse ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 100 A
... effect current sensors for DC and AC, Pulse current measurement in PCB and panel mount versions. This SCK28 series is a open loop current sensor ...
Shenzhen Socan Technologies Co.,Ltd
Primary current: 500, 1,000, 2,000 A
... AC/DC CURRENT SENSOR CT6877 Raising the Bar for High-Accuracy Measurement Overview Hioki pass-through AC/DC current sensors are best-in-class devices for use with power ...
Primary current: 50, 100 A
... The sensors in the QI-HSC series measure DC and AC currents with high accuracy and a wide range of measurements. The QI-HSC use the Hall effect measurement technique ...
Primary current: 5 A - 2,500 A
Primary current: 5, 50, 100, 200, 400 A
... DENTs SRS (small) & SRL (large) Series hinged split-core current transformers are designed for Revenue Grade IEEE Class Metering applications that require maximum accuracy and precision. The superior performance, robust ...
DENT INSTRUMENTS
Primary current: 100 A - 1,600 A
... Just open the sensor and wrap it around the power cable you want to measure. Thereby it is the perfect sensor for energy audits. This current sensor can also be used ...
Primary current: 0 A - 100,000 A
... large conductors. Specifications: Current Range: 10A to 100kA Rated output: 0.333Vac at rated current with Integrator,100mV/per 1000A @ 50Hz without integrator Accuracy:±1% from 5% to 120% of rated current ...
Jiangyin Spark Electronic Technology Co.,LTD
Primary current: 25 A - 100 A
... Effect Current Sensor) adopts the Hall Effect to measure the AC and DC current of the power grid in real time. Using precision constant current ...
Mianyang Weibo Electronic Co., Ltd
Primary current: 5 A - 30,000 A
... The MICATU Medium Voltage & Current Sensor System utilizes a 100% “all-optical” measurement platform for unparalleled accuracy and precision of both voltage and current across multiple ...
MICATU, Inc.
... and economical without special magnets. Precision Products’ line of rugged ZED3X non-contact displacement sensors are IP-67 rated with hermetic options available. For installation versatility, ZED3X sensors ...
ZSY Group Ltd.
Primary current: 6 A - 1,000 A
... of current sensors for DC and AC measurement in PCB and panel mount versions. The VAC-invented principle of a closed loop current sensor with a magnetic ...
Primary current: 50 A
... multi-range current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic ...
Rongtech Industry (Shanghai) Inc.,
Primary current: 100 A - 100,000 A
... Measuring range: - 100 A - 200 kA Current: - AC / DC Sensitivity: - 150 mV / kA at 50 Hz Diameter: 170 mm (6.7") inner & 200 mm (7.9") outer Cable length: - 2 m (78.7") ...
Matuschek Meßtechnik GmbH
Primary current: 6 A - 50 A
... controls the powerful flow of current. It uses closed loop fluxgate system.It gives best result at +105℃ and -40℃. Consist of Multi-Busbar,F02 and F03 with source access. It has four main models with primary nominal current ...
Primary current: 5 A - 30 A
... details. Features •Input current from 5 Amp to 30 Amp •Output 0.333 Volt AC at rated current •Phase angle < 1 degrees measured at 50% rated current •Linearity accuracy ± 1% •Accuracy ...
Manutech Europe
Primary current: 0 A - 30 A
... This device is a AC current isolation transducer, input and output are not common-grounded, input signal is AC current, output signal is 0-5V. With characteristics of high precision, ...
Primary current: 50, 100 A
... MONITOR Control the production of energy, Track and analyze a consumption. Current transducer: Operating temperature: -25°C / +60°C Fire resistance: UL94-V0 Precision: +/- 2% About 70 cm of cable Version 100 ...
Primary current: 100 A
... The ESS 076 smart current sensor measures the AC current of cables without contact. Measured data is output in analog (4-20 mA signal) or digital (IO-Link) form. Measured and processed ...
Primary current: 0 A - 500 A
... BMS-HCT 500 is a type of current detector comprises of large current fuse and high precision Hall current sensor. It is used in conjunction with BMS-LA500 (Lead-acid ...
Primary current: 1 A - 5,000 A
... CSN® Current Sensors are used for current measurement in control and protection systems in power transmission links (AC and DC applications). The CSN® type Current ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group