Transformers

Do you need help making a decision?  Take a look at our buying guide
255 companies | 1,616 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
Search
Transformers | Choosing the Right Transformer
There are 5 main types of transformers. The differences between each transformer are related to the types of applications possible. Current transformers: these are transformers in which the secondary current is proportional to the primary current. They can be used with all low-frequency alternating currents. Power transformers: these are distribution transformers with a voltage of one phase higher than 1,000V. They are used to transport electricity over long...
current transformer
current transformer
TQ30

... The very compact ELEQ TQ30 split-core current transformer is especially designed for connection to digital measurement systems. The TQ30 is supplied with color coded secondary leads. All current transformers are capable ...

See the other products
ELEQ
distribution transformer
distribution transformer
TER series

Electric power: 1 kVA - 160 kVA
Primary voltage: 950 V - 6,600 V

... Single-phase sets for sigle-phase networks : 1 to 50 kVA o Single-phase transformers for three-phase networks : 1 to 50 kVA o Three-phase transformers for three-phase networks : 5 to 160 kVA * ...

See the other products
Augier
measurement transformer
measurement transformer
SPT-0375

Primary voltage: 115 V - 460 V
Secondary voltage: 333 mV
Primary current: 4 mA - 20 mA

... Magnelab SPT-0375 Transformer When you are asked what is a potential transformer, simply show them the SPT-0375 voltage transformer. It offers output AC voltage that is linearly proportional to the ...

See the other products
Manutech Europe
isolation transformer
isolation transformer

Electric power: 30 W - 30,000 W
Primary voltage: 230, 400 V
Secondary voltage: 48, 12, 24 V

... Compliant with standard EN 61558-2-6 • Standard voltages • Other voltages available on request • Electrostatic screen available on request • Ambient temperature 40 °C • Protection rating IP00 • Electrical protection rating I • Thermal insulation ...

See the other products
ced
power transformer
power transformer

Primary voltage: 7.4 kV

... Breathing type transformers • Designed to work with a 24 pulse converter • Suitable to operate in parallel with an identical transformers in order to achieve power source close to 48 pulse • Copper windings • IP55 ...

See the other products
CELME SRL
instrument transformer
instrument transformer

Primary voltage: 0.6 kV

... 1 - Current transformers : from low voltage up to 36 kV - wire wounded or ring type - indoor or outdoor - single or multiple cores - ratio, accuracy and burden on demand ...

current transformer
current transformer
IJCT-24-1

Primary current: 40 A - 80 A

... Operating temperature: -40~65℃ Primary Current (Amp.)50/60Hz: 40A-80A Accuracy @RL≦10Ω: Class 2% Turns ratio: 1:1000; 1:2000; 1:2500; 1:3000 ...

current transformer
current transformer
AK 12

Primary current: 5 A - 600 A

... We produce supporting type current transformers for indoor installation. They contain up to five cores for revenue metering and protection purposes, constructed from high quality siliceousor nickel steel laminations. All active parts ...

See the other products
TWB SA
current transformer
current transformer
LMK series

... LMK3-0.66 series transformer is indoors type current transformer,is applicable for circuit of rated frequency 50Hz or60Hz,rated voltage is 0.66kV and below. It is used to transmit signal to measure meter,or relau protection,control ...

See the other products
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
power transformer
power transformer

... The earthing transformer is used to provide a grounding neutral point for the three-phase power grid, which can be connected to the ground directly, through the arc suppression coil, through the small resistance and through the current-limiting ...

See the other products
BEIJING POWER EQUIPMENT GROUP CO LTD
power transformer
power transformer

... Our encapulated transformers are including EI series and switching series. SMP Module Series 3.3W & 5W EE20/6mm Series EE20/10mm Series EI30/5mm Series EI30/10.5mm Series EI30/12.5mm Series EI30/15.5mm Series EI30/18mm Series EI38/13.6mm ...

See the other products
Dongguan Wahhing Electrical Appliance Co., Ltd.
power transformer
power transformer

... Low frequency (50/60hz) transformers make up the widest and most complete range of Comelit products. It includes laminate and toroid core solutions, encapsulated and non, for PCB assembly, panel assembly, outputs with leads and with ...

See the other products
Comelit s.p.a
electrical power supply transformer
electrical power supply transformer
IRC CONNECT IRC-B

Electric power: 18 W
Primary voltage: 100 V - 240,000 V
Secondary voltage: 6 V

... More than a cable replacement General Overview IRC-Connect transforms your transducer into a smart wireless transducer that makes work in cramped spaces much easier. This is more than just a cable eliminator and comes packed with functionality that ...

step-up transformer
step-up transformer
MAGNUS

Primary voltage: 230, 115 V
Secondary voltage: 0 V - 2,000 V
Primary current: 1 A - 10 A

... excitation curves for instrument transformers • Demagnetize current transformer cores • Conduct turn ratio tests on voltage transformers • Two-handed control enhances personal safety ...

current transformer
current transformer
HF

... When a current transformer is used instead of a quadrupole, the current transformer can be placed around a coupling capacitor terminal or around a part of the test object itself. A current transformer ...

control transformer
control transformer
IPC 300

Electric power: 38,000, 21,000, 26,600, 14,700 W
Primary voltage: 20 V - 400 V
Primary current: 100, 200, 70 A

... The JUMO IPC 300 is an electronic transformer for controlling heating loads. Due to the amplitude control, the mains current is proportional to the required performance. This reduces interference (flicker, harmonics) and energy costs ...

current transformer
current transformer
CTW1 series

Primary voltage: 500 V
Secondary voltage: 0.5, 0.2 V
Primary current: 100 A - 800 A

... The CTW Series are clamp-on current transformers that can be installed much easier than conventional current transformers, whereby saving installation cost. These transformers are particularly useful ...

power transformer
power transformer
Ha-VIS pCon 7000

Primary voltage: 110 V
Secondary voltage: 24 V

... Category Accessories Type of accessory DC-DC-converter Fixing Wall mounting flat Power consumption 950,000 h Material (hood/housing) Metal Colour (hood/housing) Black RoHS compliant ELV status compliant China RoHS e REACH Annex ...

See the other products
HARTING
power transformer
power transformer
S13-M.RL-30~2500/10

Electric power: 0.1 W - 21,200 W
Output power kVA: 30 kVA - 2,500 kVA

... an experienced and reliable manufacturer and supplier of power transformer. ZTT transformers always play a key role in the reliable transmission and distribution of power. ZTT transformer range covers ...

current transformer
current transformer
855-305/100-201

Output power kVA: 0.25 kVA
Primary current: 100 A
Secondary current: 5 A

... WAGO's plug-in current transformers (855 Series) are inductive, single-conductor current transformers. Due to the measurement principle used, these current transformers are exclusively designed for AC ...

power transformer
power transformer

... of AC and DC transformers that responds to today’s process requirements: •Manual gun transformers •Robotic gun transformers. •Machine transformers In addition to our transformer ...

measurement transformer
measurement transformer
HZG Dry Type

... of transformer. This series products have features of light weight, small volume, beautiful appearance, stable performance, convenient usage and carrying, especially suitable for site operation, are new generation high voltage testing ...

See the other products
Huazheng Electric
measurement transformer
measurement transformer
HZJ Oil Type

Electric power: 1,500 W - 250,000 W
Primary voltage: 200 V - 400 V
Secondary voltage: 50 kV - 250 kV

... Structure The transformer is constructed from high-quality cold-rolled silicon steel sheets, available as HZJ alternating current test transformers and HZJZ alternating and direct current amphibious light high voltage ...

See the other products
Huazheng Electric
immersed transformer
immersed transformer
HZJ series

Output power kVA: 1.5 kVA - 250 kVA
Primary voltage: 200 V - 500 V
Secondary voltage: 50,000 V - 250,000 V

... immersed high voltage testing transformer is engineered to deliver reliable and accurate performance, making it an essential tool for testing and measuring high voltage equipment and components. Structure The transformer ...

See the other products
Huazheng Electric
current transformer
current transformer
SC30 ... 50

Primary current: 60 A - 1,000 A

... Split-Core Current Transformers Thanks to their compact design, split-core current transformers are especially well suited for use in difficult to access locations and tight spaces. Split-core current transformers ...

current transformer
current transformer
TR-AMP series

Primary voltage: 4 kV
Secondary voltage: 4 kV

... Case in self-extinguishing UL94-V0 material Isolation voltage between primary and secondary: 4KV ...

instrument transformer
instrument transformer
HJ series

Primary voltage: 6 kV - 220 kV

... >

  • Calibration standard for voltage transformers in power supply and production departments
  • On-site field calibration and verification
  • Laboratory reference transformer and test transformer

Documentation
    ...

    current transformer
    current transformer
    HL series

    ... The HL Standard Current Transformer is a calibration standard designed for verification and error testing of current transformers. It consists of a primary winding and a secondary winding and supports self‑calibration ...

    power transformer
    power transformer
    ETR series

    Output power kVA: 1 kVA - 600 kVA
    Primary voltage: 230, 400 V
    Secondary voltage: 230, 400 V

    ... 2500V ●Supply transformers ●Voltage changing transformers Provide isolation between network installations and sensitive electronic loads. Insulated aluminum or copper windings are wound on a high efficiency sheet ...

    exhibit your products

    & reach your clients in one place, all year round

    Exhibit with us
    DirectIndustry RFQ: Free quotation comparison tool
    Receive and compare quotations for free
    Describe your project
    We select
    the best suppliers
    Compare quotations and complete your purchase