- Electricity - Electronics >
- Energy: Production and Distribution >
- Two-winding transformer
Two-winding transformers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 0.025 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24, 230, 115 V
... Safety and circuit separation transformers from 25 to 2500 VA Universal range 25 VA to 2500 VA - Double winding Fixing on omega rail (depending on model) or panel (screw) Secondary earthing by plug-in jumpers (depending ...
Electric power: 20,000 kVA - 600,000 kVA
... System / Two winding transformers have Delta stabilizing winding that is offered to some transformers for the harmonic suppression. ...
Electric power: 50 W - 2,000,000 W
Primary voltage: 1 V - 1,000 V
Secondary voltage: 1 V - 1,000 V
... Our 1-Ph and 3-Ph insulation transformers are designed to meet the following priority requirements: Anti-jamming screening between the primary and secondary windings Cooling: air type Power: up to 2000 kVA Frequency: ...
Output power kVA: 7.4 kW - 626.7 kW
... a series of transformer products, including 6300~80,000kVA double- winding and three- winding non-excitation voltage-regulating power transformer, 6300~80,000kVA double- winding ...
Output power kVA: 30 kVA - 1,600 kVA
Primary voltage: 23 kV
Secondary voltage: 0.4 kV
... – Power
Transformers
·IEC 60076-11 – Dry-type Power
Transformers
·IEEE C57.12 series – Distribution
Transformers
·IEC 60296 – Mineral insulating oils
A 23 kV distribution
transformer ...
Dowei Electric
Output power kVA: 30 kVA - 1,600 kVA
Primary voltage: 12 kV
Secondary voltage: 0.4 kV
... 2500 kVA
·3150 kVA
·5000 kVA
Main Components
·Amorphous alloy core
·High-voltage
winding
·Low-voltage
winding
·
Transformer tank
·Insulating oil or dry-type insulation ...
Dowei Electric
Output power kVA: 75 kVA - 5,000 kVA
Primary voltage: 15 kV
Secondary voltage: 0.4 kV
... medium-voltage feeder supplying the
transformer.
·Loop-feed:
Two incoming feeders allowing the
transformer to remain energized from an alternate source if one feeder is isolated.
Pad-mounted ...
Dowei Electric
Output power kVA: 1 kVA - 800 kVA
Frequency: 50 Hz - 400 Hz
... Description
Three-phase
transformer with separate primary and secondary
windings, rated from 1 kVA to 800 kVA. Designed for industrial applications requiring frequency support from 50 Hz up to 400 Hz and available ...
Output power kVA: 3.2 kVA
Primary voltage: 380, 400, 415 V
Secondary voltage: 30, 22 V
... TD series power transformer serves as isolation power-supply which is suitable for AC circuits, and rated voltage is or below. This kind of transformer is manufactured with advanced process and précisé design. Features 1.Hi-B ...
Primary voltage: 480, 600 V
Secondary voltage: 280, 120, 240 V
... purpose isolation transformers are used to lower distribution voltages (480V or 600V) to lower voltages (typically 120/240V or 280Y/120) for power distribution within commercial or industrial buildings. These “ two windings” ...
... These transformers are manufactured to VDE 0570/IEC 61558 and meet the conditions for normal use without special requirements. The power values listed refer to the version with separate windings and in the case of ...
Getra
Output power kVA: 630 kVA - 31,500 kVA
Primary voltage: 35 kV
Frequency: 60, 50 Hz
... SummarThe 35kV transformer, the use of company-specific calculation and verification procedures, the transformer core, coils, active part, leading tanks and other components for a full range of optimized design and verification, ...
Output power kVA: 3 kVA - 40 kVA
Primary voltage: 415, 230 V
Primary current: 7.22 A - 173.91 A
... Larger single-phase Transformers using UI two limb construction. The Transformers conform to IEC61558 and IEC60076 and are available with a range of voltage and connection options. • Control Transformer ...
Primary voltage: 230 V
Secondary voltage: 115 V
Frequency: 60, 50 Hz
... Medical isolation transformers have been manufactured with strengthened isolation. The transformers’ leakage current between the primary and secondary windings. A transformer used ...
Muuntosähkö Oy - Trafox
Output power kVA: 50 kVA - 2,500 kVA
Secondary voltage: 1.1 kV - 36 kV
Frequency: 50, 60 Hz
... STD Cast Resin Transformers have at least one of the two windings embedded on an autoclave mould, at vacuum values close to zero with epoxy resin. The other winding can also be cast in ...
Electric power: 0 W - 500,000 W
... Technical features Power : Up to 500 kVA Frecuency : 50-60 Hz Isolators : Class F or H Winding : Class HC-200ºC Protection degree : IP-00 to IP-65 Nema 1 to Nema 4X Environment Temperature : 40ºC Standards : UNE-EN 61558-2-1 UNE ...
Electric power: 1 W - 100,000 W
Primary voltage: 1 kV - 63 kV
Secondary voltage: 120 V - 52,000 V
... ELETTRO know-how since 1969, our HV/LV dry-type transformers offer partial discharges < 5 pC, below the required 10 pC normative requirements, to guarantee an optimised lifetime of the dry-type transformer. Description The ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group