Open programmable and configurable FSoE Masteer module for operation on EtherCAT networks
14 safe digital inputs
Up to 5 safe cut-off channels
2 Relay outputs
Fast channel task with guaranteed processing time of 4 ms
Easy integration of safe drives (Safe Drive Profile)
Safety control suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
Optional: kinematics module, FSoE-/ PROFIsafe slave stack
Ethernet-based fieldbus interface, safe / non-safe
Memory card for safety program
Characteristic of the module
Connection of max. 32 FSoE slave modules
Safe logic processing of input, output, status and activation signals
Simple and transparent programming and parameterization in the EtherCAT environment with SafePLC2
Fast response time with integrated Fast channel task with guaranteed processing time of 4 ms
Central or decentralized drive monitoring possible
Complete set of Drive monitoring of single axes and calculated axes (based on kinematics function)
Temporary deterministic data exchange and central parametrization that can be adapt to converter/manufacture
Profiles specifically adaptable to inverter types / manufacturers for process data exchange and central parameterization
Safe cross communication (SMMC: Safe Master-Master Communication) for data exchange between FSoE Master via EAP
Storage of safe parameters in SCU master
Coded status display via front-side 7 segment display and status LEDs
Multifunction button (Quit, Start, Reset) can be operated from the front side