Ultrasonic sensing for boreholes and drilling equipmentThe BBUA-DH series provides 64 kHz and 90 kHz configurations for downhole drilling measurement, borehole-wall inspection, subsurface acoustic sensing and integration into drilling equipment. The two frequencies have different beam angles and electrical characteristics.
Frequency and operating configurationsCenter frequency | Half-power beam angle | Minimum impedance | Capacitance at 1 kHz | Peak operating voltage | Operating temperature | Pressure rating | Protection rating
64 kHz ±5% | 22° ±10% | 1,100 Ω ±20% | 1,200 pF ±20% | <2,250 Vpp | -40 to +80°C | ≤1 MPa | IP68
90 kHz ±5% | 17.1° ±10% | 180 Ω ±20% | 4,600 pF ±20% | <2,250 Vpp | -40 to +80°C | ≤1 MPa | IP68
Confirmed bandwidthFrequency | Bandwidth
90 kHz | ±20% at -3 dB
Applications and selection- Measurement during downhole drilling
- Inspection of borehole walls
- Subsurface acoustic sensing
- Integration into drilling equipment
Technical specifications- Series: BBUA-DH
- Available center frequencies: 64 kHz ±5%, 90 kHz ±5%
- Half-power beam angles: 22° ±10% (64 kHz), 17.1° ±10% (90 kHz)
- Minimum impedance: 1,100 Ω ±20% (64 kHz), 180 Ω ±20% (90 kHz)
- Capacitance at 1 kHz: 1,200 pF ±20% (64 kHz), 4,600 pF ±20% (90 kHz)
- Peak operating voltage: <2,250 Vpp
- Operating temperature: -40 to +80°C
- Pressure rating: ≤1 MPa
- Protection rating: IP68
- Confirmed bandwidth (example): 90 kHz ±20% at -3 dB