Radar level transmitter EchoPro® EchoPro® LR21
liquidanalogHART

radar level transmitter
radar level transmitter
radar level transmitter
Add to favorites
Compare this product
 

Characteristics

Technology
radar
Medium
liquid
Interface
analog, 4-20 mA, HART
Other characteristics
stainless steel, ATEX, intrinsically safe, IP67
Level range

Min.: 0.3 m
(0'11" )

Max.: 20 m
(65'07" )

Process pressure

Min.: -1 bar
(-14.5 psi)

Max.: 5 bar
(72.52 psi)

Process temperature

Min.: -40 °C
(-40 °F)

Max.: 150 °C
(302 °F)

Description

The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or HART communicator. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks. FEATURES 316L antenna with PTFE inner shield for corrosive media Configuration via push button display or HART communicator 26 GHz. pulse radar is unaffected by vapor or condensation 12” (30cm) dead band enables utilization of the entire tank LCD displays level in feet or meters with percent of span bar Optional display mode indicates the echo signal return curve Auto-temperature compensation for accurate measurement Fail-safe diagnostics with selectable signal fail-safe outputs Recognition, storage and rejection of false echo signal returns IP67 stainless enclosure with polycarbonate display window SPECIFICATIONS Frequency: 26 GHz. Accuracy: ± 3mm Dead band: 12” (30cm) Beam angle: – 30: 12º, – 40: 8º Configuration: Push button, HART Memory: Non-volatile Display type: LCD, dot matrix Display units: Feet and meters Display bar: Percent of span Display graph: Echo signal curve Supply voltage: 21.6 to 26.4 VDC Max. consumption: 22.5 mA Signal invert: 4-20 mA, 20-4 mA Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA

Catalogs

No catalogs are available for this product.

See all of Flowline‘s catalogs

Other Flowline products

Liquid & Solids Level Transmitters

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.