Product overviewSliding door sensor combining active infrared presence detection and microwave motion detection. The OAM-DUAL II ensures safety across and around the threshold while providing reliable activation for convenient door operation.
- BLUEZONE (lookback) safety detection
- Safety/Lookback function
- Motion Detection
- Mounting up to 3.5 meters
Safety/Lookback functionThe active infrared presence detection provides two safety rows in front of the threshold. Rows can be adjusted precisely and shifted ±6° relative to the door. The Bluezone/Lookback feature adds an extra detection row that monitors the threshold; this row is automatically disabled when the presence area is cleared and the doors begin to close, removing the need for separate safety beams.
Motion DetectionThe wide microwave motion detection field detects approach from any angle and triggers rapid opening. Presence and motion areas are adjustable independently. A DIP switch selects infrared area behavior: safety only or safety plus activation. The uni-directional option allows faster closing when traffic moves away from the door to reduce energy consumption.
Easy installationMountable between 2.0 m and 3.5 m, the unit provides two relay outputs: one for safety and one for motion/activation. Installation is simplified by accessible DIP switches and shutters for quick adjustment across applications. Use of an OPTEX infrared finder is recommended to set the presence area.
QualityOPTEX automatic door sensors are designed for long-term operation and include a 3-year full replacement warranty.
Technical specifications- Model: OAM-DUAL II
- Activation Output: Form C relay, 50V 0.3A Max. (Resistance Load)
- Color options: Black
- Depth angle adjustment: AIR area -6° to +6°, Radar area +25° to +45°
- Detection area: See detection area (adjustable)
- Detection method: Active infrared reflection and Microwave Doppler Effect
- IP rating: IP54
- Mounting height: 2.0 m to 3.5 m (6'7" to 11'6")
- Noise level: < 70 dBA
- Operating humidity: < 80% (non-condensing)
- Operating temperature: -20°C to +55°C (-4°F to 131°F)
- Output hold time: Approx. 500 ms
- Power consumption: < 2.5 W (< 4 VA at AC)
- Power supply: 12 to 24VAC ±10% (50 / 60Hz), 12 to 30VDC ±10%
- Response time: < 300 ms
- Safety Output: Form C relay, 50V 0.3A Max. (Resistance Load)
- Transmitter frequency: 24.2 GHz
- Transmitter radiated power: < 20 dBm
- Weight: 270 g (9.5 oz)
- Note 1: Specifications are subject to change without notice due to improvements.
- Note 2: For full specifications and additional notes consult the product manual.