Characteristics

Type
electric, pneumatic
Movement
linear
Other characteristics
high-performance, for fire and smoke protection
Pressure

Max.: 20.7 bar
(300.2 psi)

Min.: 20.7 bar
(300.2 psi)

Description

Product subtitle
Auxiliary releasing device for dry pilot actuation of deluge and preaction valves

Overview
The Tyco Model DP-2 Dry Pilot Actuator is an auxiliary releasing device designed for use with Tyco deluge and preaction valves having dry pilot release systems. Additionally, the DP-2 is used for Tyco preaction valves with double-interlock electric/pneumatic release. The Model DP-2 actuates these automatic water control valves upon release of air (nitrogen) pressure.

Application / Compatibility
For use with deluge or preaction fire protection systems and compatible Tyco valves

Certifications
UL and C-UL Listed; FM Approved

Features
  • Maximum water pressure: 300 psi (20.7 bar)
  • UL and C-UL Listed; FM Approved
  • High air-to-water ratio performance (22 psi / 175 psi)
  • AMD-3 Nitrogen Maintenance Device recommended for systems requiring dew point control below -20°F (-29°C)

Benefits
  • Industry-leading warranty — Johnson Controls stands behind its products (see terms for details)
  • Proven performance — Tyco® products have protected facilities for over 130 years
  • Broad product portfolio — integrates with a wide range of Tyco fire protection solutions

Technical specifications
  • Model: DP-2
  • Function: Auxiliary releasing device / dry pilot actuator for deluge and preaction valves
  • Actuation medium: Release of air (nitrogen) pressure
  • Max water pressure: 300 psi (20.7 bar)
  • Max system air/nitrogen pressure: 300 psi (20.7 bar)
  • Air/water ratio: 22 psi / 175 psi
  • Approvals: UL, C-UL, FM
  • Recommended ancillary device: AMD-3 Nitrogen Maintenance Device for dew point control below -20°F (-29°C)