- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Flow meter with LCD display
Flow meters with LCD display
Volumetric flow rate: 0 l/min - 50 l/min
... primary volume flow meter offers easy-to-use calibrations with unmatched flow ranges, accuracy and portability. The FlexCal offers you: USB connectivity Flow rate ...
CleanAir Europe
Volumetric flow rate: 0 l/min - 30 l/min
Precision: 1 %
... piston flowmeters with Bios DryCal® technology in the DC-Lite and DC-2 digital flowmeters. They allow calibration of air sampling pumps, rotometers or other flow instruments. Depending ...
CleanAir Europe
Volumetric flow rate: 0 l/min - 30 l/min
Precision: 1 %
... ® technology in the DC-Lite and DC-2 digital flow meters is available in the Defender 510The Defender 510, 520 and 530+ calibrators make it easier than ever to calibrate air sampling ...
CleanAir Europe
Volumetric flow rate: 0.3 m³/h - 71 m³/h
Process temperature: -15 °C - 100 °C
Process pressure: 0 bar - 10 bar
EPR Paddle Wheel Flow Meter mainly by using the principle of rotating blades to measure flow. Mainly by the middle of the leaf blade and the leaf blade capacity calculated. In the structural ...
Volumetric flow rate: 0.2 l/min - 100 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 16 bar
... equipped with a display for immediate monitoring and simultaneous display of flow and temperature. Compact construction ideal for use in tight spaces, high shock and vibration resistance. PRODUCT ...
Riels Instruments
Volumetric flow rate: 0.9 m³/h - 26.5 m³/h
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... Electronic Flow Converter CV010 It can be supplied in the compact version connected directly to the body or in the separate version connected to the body with a special cable of minimum length 10 meters. The ...
Riels Instruments
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
... gallons [Mg], US oil barrels [OB], UK oil barrels [IB] Display - Yes Display version - Electronic Display technology - LCD B/W Touchscreen - No Display ...
Riels Instruments
AI.FFsonic MODEL Flow measurement at fixed transit time Speed range: max. ± 32m / s - Views: instantaneous flow, totalizer (volume) Outputs: 4 ÷ 20mA + 1 open collector + 1 relay Digital output ...
ASIT ITALIA
Process temperature: -30 °C - 160 °C
Precision: 1 %
... provides over 12 hours of continuous operation Measurement: non-invasive clamp-on transducer, no pressure drop, no pipe disturbance Menu support in multiple languages: English, Italian and other languages can be customized Large ...
ASIT ITALIA
Process temperature: -30 °C - 160 °C
Precision: 1 %
Repeatibility: 0.2 %
The AI.M-SONIC flow measurement system is an innovative modular system consisting of a small-sized module including display, omega bar mounting, digital and two clamp-on or insertion ...
ASIT ITALIA
Precision: 0.2 %
... ADVANTAGES OF ELECTROMAGNETIC FLOWMETERS OVER OTHER FLOWMETERS · There are no mechanical parts that prevent the flow and reduce the pressure. · Measurement scale; It is ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
... precise flow measurements can be made without the need for costly modifications on the existing line. There are no mechanical parts that prevent the flow or reduce the pressure. measurement scale; It ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
Mass flow rate: 2.2 kg/h - 243,954.9 kg/h
Volumetric flow rate: 0.5 m³/h - 14,000 m³/h
Process pressure: 1 bar - 25 bar
... password setup, the parameters setup, total flow reset and calibration can be set with different- level passwords, it is convenient for management * Three-Wire system supports RS485 communication * The display ...
ENELSAN ENDUSTRIYEL ELEKTRONIK SANAYII A.S.
... compressed air flow meter is designed to be easy to use, affordable and it's offering a wide measurement range. This makes it easy for you to choose the right flow meter, ...
Volumetric flow rate: 1 m³/h - 3,600 m³/h
Process pressure: 1.6 MPa - 16 MPa
Precision: 1.5, 1 %
Precession vortex flow meter adopts micro-processing technology, which has the advantages of strong function, wide flow range, simple operation and maintenance, and convenient installation ...
Volumetric flow rate: 1 l/h - 600 l/h
Process temperature: -20 °C - 60 °C
Process pressure: 2 bar - 25 bar
... with kinematics viscosity of 1.5 cSt to 6 cSt can be measured by DFM. DFM fuel flow meter is a tool for direct fuel consumption measurement, the data from the flow meter ...
Volumetric flow rate: 90 m³/h - 1,195 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... consumption of individual machines and analyze your leakage flows with just one measuring device. Advantages of the VA 525 flow sensor: - Measurement of mass flow rate, output of ...
Volumetric flow rate: 909 m³/h - 1,195 m³/h
Process temperature: -30 °C - 80 °C
Process pressure: 0 bar - 40 bar
... - Temperature range up to 80°C - Integrated display to show the measured values - Available from ½" to 2'' - Settings adjustable via the keys of the display - Main counter can be ...
Volumetric flow rate: 0 m³/h - 1,000 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 Pa - 3,500,000 Pa
... loss monitoring. It measures (bi-directional) mass flow, temperature, pressure, and total flow which is key data for point of use compressed air energy /technical gas management. On the bright blue display ...
Process temperature: -40 °C - 150 °C
Process pressure: 0 bar - 16 bar
Precision: 2 %
... with this 4-in-1 sensor: measure (bi-directional) flow, pressure, temperature, and total flow simultaneously. The patented VPFlowScope® DP is the ultimate measurement tool for saturated compressed air ...
The B-Alert is a flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. The display shows flow ...
Process temperature: -20 °C - 50 °C
... TX175 FLOW TRANSMITTERS The FM101 is an LCD digital panel meter for displaying process flow rates. Housed within a robust enclosure with a high ...
Process temperature: -10 °C - 100 °C
Process pressure: 0.2 MPa
Precision: 0.5 %
... 10 - 100°C / ±0.5% - Power supply - - 8-24 - Vdc Output - Analog / RS485 (Modbus) / l2C - - Optional interface - LCD display / 4~20mA / Bluetooth LE - - Working température - - -10-95 - °C Mechanical ...
SIARGO
Process temperature: -10 °C - 55 °C
Process pressure: 1, 1.5 MPa
Precision: 1.5 %
MF5100 series mass flow meters are designed for a large dynamic range (200:1) and high accuracy of 1.5% of reading in flow metering and control applications. With Siargo's proprietary MEMS ...
SIARGO
Process temperature: -20 °C - 70 °C
Process pressure: 1 MPa
Precision: 1.5 %
MF5600 series mass flow meters are designed for general purpose flow metering and control applications where a detachable meter heat is required for some distance data ...
SIARGO
Process temperature: -10 °C - 60 °C
Precision: 2 %
Repeatibility: 0.2 %
E3E Clip-on Ultrasonic Thermal Energy / BTU Flow Meter is simple and convenient to install, and it adopts POE power supply and Ethernet communication to realize cloud data storage. Our E3E adopts ultrasonic ...
Gentos
Process temperature: -10 °C - 60 °C
Precision: 2 %
Repeatibility: 0.2 %
... adopts ultrasonic transit time measurement principle, combined with Gentos patented flow algorithm technology, it realizes the accurate measurement of the fluid flow in the pipe. The product is simple ...
Gentos
Process temperature: -10 °C - 60 °C
Precision: 2 %
Repeatibility: 0.2 %
... pipe damage LCD colorful display screen 360°rotation adjustable display screen E3CL/E3RO Clip-on Ultrasonic Thermal Energy /BTU Flow Meter adopts ...
Gentos
Process temperature: -20 °C - 60 °C
Process pressure: 0.5 bar - 1.5 bar
Precision: 0.2 %
... performance ratio Instantaneous and totalized flow measurement No. 2 freely programmable relays MODBUS; Bluetooth communication protocol Remote control via Smartphone Flowmeter is an ultrasonic ...
Volumetric flow rate: 0 m³/h - 24,000 m³/h
Process temperature: -40 °C - 80 °C
Precision: 1 %
... Measurement range DN25 ÷ DN1200 Datalogger on SD card Backlit display Battery life: max 6h MODBUS RTU digital communication Description The SGM-101H flow measurement system ...
Process temperature: -10 °C - 80 °C
Precision: 1 %
Repeatibility: 0.2 %
Non-intrusive flowmeter for transit time for measurement of clean liquids. Electroinica mural with power to 220 Vac or 10/30 Vdc. Available with three types of sensors A (for pipes of 20 to 100 m), B (for pipes of 60 ...
Process pressure: 10.3 bar
Description Agrimag is the new Arkon electromagnetic flowmeter for agricultural applications. It is a low cost plastic electromagnetic flowmeter that is powered by 6 standard AA batteries (battery life ...
Arkon Flow Systems
... 10% to 100% of full scale range • - Power supply range is 9-35 VDC • - One frequency output, open collector • - LCD display 128x64 px graphical • - Empty pipe detection • - Body material: polypropylene • ...
Arkon Flow Systems
Process pressure: 10.3 bar
... full scale range • - Power supply range is 9-35 VDC • - 4-20mA current loop output • - RS485 Modbus RTU output • - LCD display 128x64 px graphical • - Empty pipe detection • - Body material: polypropylene • ...
Arkon Flow Systems
Volumetric flow rate: 0 l/min - 150 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 200 bar
Process temperature: -20 °C - 150 °C
Precision: 1, 0.5, 0.2 %
PT124B-502 intelligent integrated turbine flowmeter adopts advanced ultra-low power consumption single-chip microcomputer technology, with double-row LCD on-site display, with compact ...
Volumetric flow rate: 0.5 us gal/min - 20 us gal/min
Process pressure: 300 psi - 1,500 psi
Precision: 5 %
Variable Area Vane-Style Flowmeter for 0.5 - 20 GPM General Applications (SN) The SN series has the following characteristics and/or options: Local indication of flow rate. Mechanical pointer Mechanical ...
UNIVERSAL FLOW MONITORS
Volumetric flow rate: 0.3 m³/h - 1,600 m³/h
Process pressure: 100 Pa - 780 Pa
... years, and the memery can store data for 12 months ( a set of data per hour). The meter head can rotate freely and easy to reading data 1: strictly prohibit the flow meter on-line ...
Volumetric flow rate: 15 m³/h - 12,000 m³/h
Process temperature: -15 °C - 70 °C
Precision: 0.3 %
... process variable detected by the multivariable sensor to give an accurate mass flow rate. High-accuracy mass flow rate measurement This air monitoring and management flowmeter achieves ...
Azbil
Volumetric flow rate: 0 l/min - 20 l/min
Process temperature: -20 °C - 110 °C
Process pressure: 30, 10 bar
... Ultrasonic Flowmeter range Utilising patented technology that enables it to operate with excellent accuracy over very wide flow ranges, across the whole span, the Atrato range of inline flowmeters ...
... Flexible Digital Communications with HART, DE and Foundation Fieldbus Protocols Intuitive, versatile operator interface with large characters and back-lit LCD dispaly Optional I/O capability ...
Process temperature: -40 °C - 160 °C
Precision: 1, 1.5, 0.5, 0.2 %
... transit-time ultrasonic flowmeter with clamp-on sensors for non-invasive liquid measurement. Based on microprocessor and programmable flow measurement techniques the process flow can ...
ALIA GROUP INC
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining