- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Plastic flow meter
Plastic flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Volumetric flow rate: 2 m³/h - 850 m³/h
Process temperature: 4 °C - 49 °C
Process pressure: 30 psi - 200 psi
... compressed air pipe. If the unit needs to be removed, blocking rings are available for most models. Available for measuring air flow in SCFM or m3/hr on 1/2" thru 8" Schedule 40 Iron Pipe, 25mm thru 101mm Aluminum Pipe ...
EXAIR

Volumetric flow rate: 2 m³/h - 850 m³/h
Process temperature: 20 °F - 120 °F
Process pressure: 0 psi - 250 psi
... compressed air pipe. If the unit needs to be removed, blocking rings are available for most models. Available for measuring air flow in SCFM or m3/hr on 1/2" thru 8" Schedule 40 Iron Pipe, 25mm thru 101mm Aluminum Pipe ...
EXAIR

Volumetric flow rate: 2 m³/h - 3,398 m³/h
Process temperature: 20 °F - 120 °F
Process pressure: 200 psi
... models. Available for measuring air flow in SCFM or m3/hr on 1/2" thru 8" Schedule 40 Iron Pipe, 25mm thru 101mm Aluminum Pipe and for Copper Pipe up to 4". Advantages Provides wireless monitoring of EXAIR flowmeters ...
EXAIR

Process temperature: -15 °C - 80 °C
... portable area velocity meter that measures flow using a submersible ultrasonic sensor. The unit is designed for flow surveys in open channels, partially-full sewer pipes, and surcharged ...

Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -40 °C - 150 °C
... from one transducer to another. The time between transmitted and received signals is measured by the flow meter. Mount the TTFM 6.1 Transit-Time Flow Meter ultrasonic ...

Volumetric flow rate: 0 l/min - 1.7 l/min
Process pressure: 100 bar
... This way e.g. motor and / or magnetic valve and the most different processes can be controlled. Flow meter for 0,04 - 1,67 l/min. Technical data: - Flow rate: min. 0,04 l/min - ...

Volumetric flow rate: 0.3 l/min - 8.3 l/min
Process pressure: 100 bar
... This way e.g. motor and / or magnetic valve and the most different processes can be controlled. Flow meter for 0,25 - 8,3 l/min. Technical data: - Flow rate: min. 0,25 l/min - ...

Process temperature: 0 °C - 50 °C
... Collector: 1 point: Relay Contact: 1 point. Serial Communications: RS- 232C or RS-485. Enclosure Rating: IP65. Materials: - Plastic ABS. Electrical Connections: - Screw terminais. Mounting: - Wall or pipe mount. Weight: 1.8 ...

Volumetric flow rate: 5 l/min - 120 l/min
Process pressure: 8 bar
... install on all Drum and container pumps: The new Lutz Flow Meter TR3 in PP or PVDF. A handy meter you can "count" on in any situation. The symmetrical measuring chamber allows the meter ...
Lutz Pumpen GmbH

Volumetric flow rate: 5 l/min - 120 l/min
Process temperature: 50 °C
Process pressure: 10 bar
... mount on all Drum- and container pumps: the new Lutz Flow Meter TR3 in PP or PVDF. A handy meter that you can "count on" in any situation. The symmetrical measuring chamber allows it ...
Lutz Pumpen GmbH

Volumetric flow rate: 5 l/min - 120 l/min
Process pressure: 8 bar
... mount on all Drum- and container pumps: the Lutz Flow Meter TR3 in PP or PVDF. A handy meter that you can "count on" in any situation. The symmetrical measuring chamber allows it to be ...
Lutz Pumpen GmbH

Volumetric flow rate: 0 l/min - 4,000 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0 psi - 150 psi
... also known as purge meters. Unlike conventional VA meters these new flow meters measure mass flow instead of volume flow. For easy ...
Mass Flow ONLINE BV

Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 10 bar
... also known as purge meters. Unlike conventional VA meters these new flow meters measure mass flow instead of volume flow. For easy ...
Mass Flow ONLINE BV

Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 10 bar
... also known as purge meters. Unlike conventional VA meters these new flow meters measure mass flow instead of volume flow. For easy ...
Mass Flow ONLINE BV

Volumetric flow rate: 0.5 l/min - 100 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0.9 bar - 7 bar
Panasonic has developed a new digital flow sensor with integrated display for a wide range of applications. The FM-200 series can control and effectively manage flows using a variety of output modes. The ...

Process temperature: 0 °C - 100 °C
Process pressure: 2 bar - 12 bar
Variable area flowmeter for basic water applications • Plastic tube with scale and a MIN/MAX switch • Very cost-effective flow indication • Thread: G1⁄2, G1, G2; or adhesive sleeve • ...

Volumetric flow rate: 0 l/min - 700 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 10 bar
The new KOBOLD flow meter Type MIK is used for measuring and monitoring smaller and medium-sized flow of conductivity liquids in pipes. The device operates according to the electromagnetic ...
KOBOLD Messring GmbH

Process temperature: 0 °F - 250 °F
Process pressure: 0 psi - 200 psi
... osimple means of panel mounting model P single flow tube meters Designed for low flowrates, the model P flowmeter is a precision instrument embodying the inherent ...

Volumetric flow rate: 0 l/min - 132.5 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 0 Pa - 1,000,000 Pa
... paddlewheel meter for liquid flow measurement. Design Features oSupports up to 23 Engineering Units (including one User Defined) oTwo programmable Totalizers (main and pilot) indicate total liquid ...

Volumetric flow rate: 7 l/min - 120 l/min
Process temperature: 16 °C
Process pressure: 20 bar
is a digital flow meter with turbine suitable for diesel monitoring and digital management of the fluid dispensed. PRECISION AND QUALITY The K24-A digital diesel flow meter ...

Volumetric flow rate: 0 l/min - 0.1 l/min
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 5 bar
Micro Flow Rate Liquid Flow Meter By combining a thermal MEMS sensor and a highly corrosion-resistant quartz glass flow path, the product can measure micro flow ...

Volumetric flow rate: 0 l/h - 12,500 l/h
Process temperature: 0 °C - 60 °C
Process pressure: 16 bar
... materials. The microflow sensor for magnetic flow meters MS600, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...

Volumetric flow rate: 0 m³/h - 180 m³/h
Process temperature: 0 °C - 50 °C
Process pressure: 6 bar
... electromagnetic meter. The plastic sensor for electromagnetic flow meters MS5000 CIAO, flow meters, energy meters, ...

Volumetric flow rate: 0.6 m³/h - 120 m³/h
Process temperature: -30 °C - 130 °C
Process pressure: 16 bar
... and flow rate IFX-M4-04 can be used to measure energy consumption for fluids, also other than water in closed or open ring energy systems and also for water consumption. The main features and advantages of the IFX ...

Volumetric flow rate: 0.1 l/min - 120 l/min
Process temperature: -20 °C - 80 °C
Process pressure: 0 bar - 30 bar
Flowmeter for liquids BSP threads Custom stairs The Flowmeter FLUP have high visibility on each side and a clear reading of the scale. Thanks to the conformation of the cone, at regular increases of ...

Volumetric flow rate: 0.1 l/min - 15 l/min
Process temperature: -25 °C - 125 °C
Process pressure: 10 bar
... transistor outputs are available on each flow meter. NSF Certified for Use in Food and Beverage Production Turbine Flow Measurement Low cost PVDF or PP body 1- 2% FSD Sapphire bearings Hall ...

Volumetric flow rate: 1.5 l/h - 60,000 l/h
Process temperature: 0 °C - 100 °C
Process pressure: 0 bar - 10 bar
Measuring tube: PA, PSU or PVC Floats: PVDF Inserts with damping feature for float in case of water hammer PVDF coated stainless steel guide rod for the dimensions DN50 and DN65 to stabilize the float Double scale ...

Volumetric flow rate: 1.5 l/h - 60,000 l/h
Process temperature: 0 °C - 100 °C
Process pressure: 0 bar - 10 bar
Measuring tube: PA, PSU or PVC Floats: PVDF Inserts with damping feature for float in case of water hammer PVDF coated stainless steel guide rod for the dimensions DN50 and DN65 to stabilize the float Double scale ...

Volumetric flow rate: 0 m³/h - 3,800 m³/h
Process temperature: 0 °C - 80 °C
Process pressure: 0 Pa - 1,500 Pa
... The venturi tube is a primary element for flow metering in tubings. The principle of the venturi tube allows for meterings with all media. The venturi tube described here is especially designed for air flow ...

Volumetric flow rate: 1 l/h - 250 l/h
Process temperature: -10 °C - 60 °C
Process pressure: 10 bar
Technical Data Service: gas & liquid Wetted parts material: Body- Polycarbonate (PC); O-Ring- Viton (standard); Float- SS316, POM Plastic Valve material: SS316 Connection material: SS316 Connection size: WN PT female; ...
Golden Mountain Enterprise

Volumetric flow rate: 0 l/h - 100 l/h
Process temperature: -24 °C - 54 °C
Process pressure: 10 bar
Technical Data Service: gas & liquid Wetted parts material: Body- Acrylic Plastic 0-ring- NBR (standard), Viton on request Float- SS316, Glass, POM Plastic Valve material: SS316 Connection material: SS316 ...
Golden Mountain Enterprise

Volumetric flow rate: 20 l/h - 500 l/h
Process temperature: -24 °C - 54 °C
Process pressure: 10 bar
Technical Data Service: Water, Air Wetted parts material: Body: Acrylic Plastic; O-Ring-Viton; Float-magnet cover with Nickel Connecting material: SS316 Connecting size: 1/4”, 3/8”NPT or PT female available Mounting: ...
Golden Mountain Enterprise

Volumetric flow rate: 5 l/min - 80 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 10 bar
... form a Kármán vortex street in the flow. The distance between the individual vortices is constant. The frequency at which the vortices flow past a sensor depends on the flow velocity ...
SIKA

Volumetric flow rate: 0.1 l/min - 250 l/min
Process temperature: -10 °C - 60 °C
Process pressure: 0 bar - 10 bar
Cost-optimized plastic design compact lightweight construction especially for series applications best price-performance ratio The sensors of the induQ® VMZ.2 series allow a flow- ...
SIKA

Volumetric flow rate: 1 l/min - 30 l/min
Process temperature: 0 °C - 85 °C
Process pressure: 10 bar
... applications high measuring accuracy, largely independent of the installation position due to integrated flow straightener Turbine flow sensors of the VTY series have been specially developed for ...
SIKA

Process temperature: -30 °C - 80 °C
... cycle operation for self-sufficient systems Flow metering at the highest technical level The NivuFlow 750 flow meter is the successor to the well-known OCM Pro CF. Compact dimensions ...
NIVUS GmbH

Process temperature: -20 °C - 70 °C
... velocity paths. The NivuFlow 650 operates over the full bi-directional flow range without causing obstruction or head loss where the large array of NIVUS transducer models permits flow measurement across ...
NIVUS GmbH

Process temperature: -20 °C - 70 °C
... Energy-saving cycle operation for self-sufficient systems Perfect flow measurement in full pipelines Insert or clamp-on The NivuFlow 600 system was developed particularly for flow measurement in ...
NIVUS GmbH

Volumetric flow rate: 0.5 l/min - 750 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
The Variable Area Flow Meters of the TFMV Series are designed for monitoring the single-stage and non-pulsating discharge of liquid or gas within a circuit. These flow meters ...

Volumetric flow rate: 0.1 l/min - 170 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
FMP...V - Variable area flow meters (panel type) The FMPV Series is a range of area flow meters from Elettrotec. It is suitable for monitoring the single-phase non-pulsating ...

Volumetric flow rate: 0.1 l/min - 170 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
FMP...VR - Variable area flow meters (panel type flow meters with regulating valve) The FMP VR Series is a range of variable area flow meters ...

Volumetric flow rate: 1.4 l/h - 500,000 l/h
Process temperature: -20 °C - 100 °C
Process pressure: 1.5 bar - 10 bar
... Stainless Steel AISI 316 and PP depending on flow medium and measuring range. All the flowmeters are equipped with min-max visual flow indicators fully adjustable. In ...

Volumetric flow rate: 1 l/min - 4,000 l/min
Process temperature: -20 °C - 65 °C
Process pressure: 6 bar
... moves in a transparent conical measurement tube, relative to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the ...

Volumetric flow rate: 2 l/h - 640 l/h
Process temperature: -20 °C - 100 °C
Process pressure: 10, 15 bar
... scale ●Set-point indicator ●Optionally switching outputCharacteristics A float moves in a transparent conical measurement tube, relative to the flow. The position of the float depends on the volume flow ...

Volumetric flow rate: 0 l/min - 700 l/min
Process temperature: 0 °C - 80 °C
Process pressure: 0 bar - 10 bar
The MIK Model is a plastic electromagnetic flow meter developed by Kobold. It comes with G ½ to G 2 ¾ male connections and an analog output. This unit is built with stainless steel and ...

Volumetric flow rate: 0.8 m³/h - 860 m³/h
Process temperature: 60 °C - 100 °C
Process pressure: 0 bar - 16 bar
The KOBOLD plastic stream meters of model KSM are based on the float standard with the float moving openly without erosion in the measuring tube. The materials are impervious to impact and compressive ...

Volumetric flow rate: 90 m³/h - 1,195 m³/h
Process temperature: -20 °C - 60 °C
Process pressure: 0 bar - 16 bar
... consumption of individual machines and analyze your leakage flows with just one measuring device. Advantages of the VA 525 flow sensor: - Measurement of mass flow rate, output of ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining