Electrochemical chlorine sensor CP4MA*-AT
for process controlfor marine applications4-20 mA

Electrochemical chlorine sensor - CP4MA*-AT - DABECO Co.,Ltd - for process control / for marine applications / 4-20 mA
Electrochemical chlorine sensor - CP4MA*-AT - DABECO Co.,Ltd - for process control / for marine applications / 4-20 mA
Add to favorites
Compare this product

Characteristics

Technology
electrochemical
Applications
for marine applications, for process control
Output
4-20 mA
Protection class
ATEX
Other characteristics
for real-time measuring, maintenance-free, with temperature sensor
Measuring range (ppm)

Min.: 0 unit

Max.: 20 unit

Description

Overview
The CP4MA*-AT is a German-made membrane-covered amperometric potentiostatic 3-electrode sensor for continuous measurement of total chlorine in seawater and vessel ballast water. It features reduced pH dependence (pH 4–12), partial tolerance to surfactants, automatic temperature compensation and a stable 4–20 mA output. Certified ATEX/IECEx as intrinsically safe for Zone 1, it is designed for installation in a flow chamber (approx. 15–30 l/h) with a T90 response time of ≈ 2 minutes. Zero-point adjustment is not required; calibration is performed using the DPD-4 method.

Special features
  • ATEX / IECEx certified — intrinsically safe for Zone 1
  • Membrane-covered amperometric 3-electrode design
  • Reduced pH dependence (pH 4.0–12.0) and partial tolerance to surfactants
  • Automatic temperature compensation and low maintenance


Applications
Monitoring of seawater and vessel ballast water; onboard treatment and ballast water management systems; process control on marine vessels.

Ambient conditions
• Maximum temperature: 45 °C
• Operating temperature: 0–45 °C
• Maximum pressure: 0.5 bar (no pressure impulses or vibrations)
• Nominal pressure: 0.3 bar (no pressure impulses or vibrations)
• Flow rate in flow chamber: approx. 15–30 l/h
• Run-in time: first start-up approx. 2 h

Technical specification
The sensor measures total chlorine (optionally pH). Measuring ranges and performance depend on electrode configuration.
  • Model: CP4MA*-AT
  • Measuring parameters: Total chlorine (optional pH)
  • Measuring ranges: 0.005…2.000 ppm / 0.05…5.00 ppm / 0.05…10.00 ppm / 0.05…20.00 ppm
  • Lower limit of measurement: 0.005 mg/L (depending on electrode)
  • Resolution: 0.001 mg/L or 0.01 mg/L (depending on range)
  • Response time: T90 ≈ 2 minutes
  • Drift: approx. −1% per month (after calibration at 25 °C, pH 7.2)
  • pH range: 4.0–12.0 (depending on electrode)
  • Material: microporous hydrophilic membrane, PVC-U, PEEK, stainless steel 1.4571
  • Output: 4–20 mA
  • Max allowable working pressure: 0.5 bar (no impulses/vibrations)
  • Nominal pressure: 0.3 bar (no impulses/vibrations)
  • Zero point adjustment: not required
  • Certification: ATEX / IECEx (intrinsically safe for Zone 1)
  • Calibration method: DPD-4 method

Catalogs

No catalogs are available for this product.

See all of DABECO Co.,Ltd‘s catalogs

Other DABECO Co.,Ltd products

Disinfectant sensor

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.