OverviewThe German-made chlorine dioxide sensor CD4.2 is a membrane-covered amperometric 2-electrode sensor for ClO₂ measurement. It features automatic temperature compensation and rapid response time, delivering high-resolution results across models. Available with analog and digital outputs (including 4-20 mA versions), it provides galvanic isolation and is offered with IP65/IP68 protection. Suitable for monitoring water disinfection in swimming-pool, drinking, service and process water (measuring water must not contain surfactants). The sensor operates at 0-45 °C, pH 1–12 and up to 1.0 bar. Low slope drift and easy maintenance ensure reliable long-term performance.
Special features- Membrane-covered amperometric 2-electrode design
- Automatic temperature compensation
- Short / rapid response time
- High resolution (range-dependent)
- Available analog and digital outputs, including 4-20 mA
- Galvanic isolation
- IP65 / IP68 protection options
- Low slope drift, easy maintenance
Applications- Swimming-pool water monitoring
- Drinking water monitoring
- Service water and process water monitoring (no surfactants in measuring water)
Ambient conditions- No surfactants in the measuring water
- Maximum temperature: 45 °C
- Maximum pressure: up to 1.0 bar (dependent on mounting / retaining ring)
Technical SpecificationMeasurement Parameters: Chlorine dioxide
Measuring Ranges: 0.005…0.500 ppm / 0.005…2.000 ppm / 0.05…5.00 ppm / 0.05…10.00 ppm / 0.05…20.00 ppm
Lower Limit of Measurement: 0.005 mg/L (depending on the electrode)
Resolution: 0.001 mg/L or 0.01 mg/L (depending on the measuring range)
Response time: T90 ≈ 15 seconds
Drift: Approximately -1% per month (after calibration at 25 °C and pH = 7.2)
pH range: 1.0 - 12.0 (depending on the electrode)
Operating temperature: 0 - 45 °C
Flow rate: In flow chamber: 15-30 l/h (approx.)
Max. allowable working pressure: Operation without retaining ring: 0.5 bar (no pressure impulses and/or vibrations); Operation with retaining ring: 1 bar (no pressure impulses and/or vibrations)
Run-in time: First start-up approx. 1 h
Material: Semipermeable membrane, PVC-U, ABS
Zero point adjustment: Not necessary
Technical features- Model designation: CD4.2
- Measured parameter: Chlorine dioxide (ClO₂)
- Measuring ranges: multiple ranges from 0.005 ppm up to 20.00 ppm
- Detection limit: down to 0.005 mg/L (electrode-dependent)
- Resolution: 0.001 or 0.01 mg/L (range-dependent)
- Response time: ~15 seconds (T90)
- Drift: approx. -1% / month (after calibration)
- pH operating range: 1.0–12.0
- Operating temperature: 0–45 °C
- Flow cell: approx. 15–30 l/h
- Max. pressure: 0.5 bar (without retaining ring) / 1 bar (with retaining ring), no pressure impulses or vibrations
- Materials: semipermeable membrane, PVC-U, ABS
- Outputs: analog/digital options; 4-20 mA available
- Protection class options: IP65 / IP68
- Design features: galvanic isolation, low maintenance, no zero-point adjustment required