OverviewThe Germany-made P9.3 PAA sensor adopts a membrane-covered amperometric 2-electrode system to accurately measure peracetic acid concentration in aqueous solutions. It delivers temperature-compensated analog outputs and Modbus RTU digital signals. Calibration is possible via downstream devices or by direct one-key calibration with compatible transmitters. The sensor tolerates water temperatures up to 60 °C, uses a chemical- and surfactant-resistant elastomer membrane, and provides low-maintenance operation. Typical accuracy is <2–3% (for the 2000 mg/L range) and response time T90 varies from approx. 45 s to 3.5 min depending on temperature. IP65/IP68 protection options, EMC and RoHS compliance, and flexible connectivity make it suitable for industrial water treatment applications such as bottle washing machines and CIP plants.
Special features- Membrane-covered amperometric 2-electrode system
- High temperature tolerance up to 60 °C (measuring water)
- Resistant elastomer membrane against chemicals and surfactants
- Temperature-compensated analog and Modbus RTU digital outputs
ApplicationsIndustrial water treatment: electroplating, pharmaceutical, food & beverage, dairy and chemical industries; examples include bottle washing machines and CIP plants.
Process conditions- Max. measuring water temperature: 60 °C (no ice crystals in the measuring water)
- Max. ambient temperature: 55 °C
- Max. pressure: 1 bar (installation-dependent; operation with retaining ring: -1.0 bar / -0.5 bar at low flow; avoid pressure surges and vibrations)
- Flow rate (face velocity): approx. 15–30 L/h in flow cell; small flow rate dependence
Technical specification (summary)- Measurement parameter: Peracetic acid (PAA)
- Measuring ranges / resolution: 0–200 ppm (0.1 ppm); 5–2000 ppm (1 ppm); 0.005–2 % (20000 ppm: 0.001 % / 10 ppm)
- Accuracy: <2–3% (for 2000 mg/L range)
- Response time (T90): approx. 45 s (at 50 °C) to 3.5 min (at 10 °C)
- Measuring water temperature: 0…+60 °C
- Ambient temperature: 0…+55 °C
- Temperature compensation: automatic via integrated sensor (avoid sudden temperature changes)
- Max. allowed working pressure: see process conditions (installation-dependent)
- pH range: pH 1 – pH 8
- Run-in time: 200 mg/L ~ 3 h; 2000 mg/L ~ 1 h; 20000 mg/L ~ 30 min
- Zero point adjustment: not necessary
- Protection class: IP65 / IP68 options (5‑pole M12 plug-on flange IP68; 2‑pole terminal with mA-hood IP65)
- Materials: elastomer membrane, PEEK, stainless steel 1.4571
- Outputs: temperature-compensated analog signals; Modbus RTU digital signals
- Compliance: EMC, RoHS
Technical specifications- Model: P9.3
- Measurement: Peracetic acid (PAA)
- Protection: IP65 / IP68
- Connectivity: analog temperature-compensated outputs, Modbus RTU
- Maintenance: low