Refrigerated compressed air dryer KD series
water-cooledmedium-size

Refrigerated compressed air dryer - KD series - Hangzhou Mairui Gas Engineering Equipment Co., Ltd - water-cooled / medium-size
Refrigerated compressed air dryer - KD series - Hangzhou Mairui Gas Engineering Equipment Co., Ltd - water-cooled / medium-size
Add to favorites
Compare this product

Characteristics

Technology
refrigerated
Other characteristics
water-cooled, medium-size
Capacity

Min.: 1,020 m³/h
(36,020.96 ft³/h)

Max.: 6,600 m³/h
(233,076.8 ft³/h)

Working pressure

Min.: 0.2 MPa

Max.: 1 MPa

Motor power

Min.: 3.1 kW
(4.21 hp)

Max.: 15 kW
(20.39 hp)

Weight

Min.: 165 kg
(363.8 lb)

Max.: 1,160 kg
(2,557.4 lb)

Description

Product Overview
These water-cooled refrigerated air dryers are offered in two subseries (KDL and KDH) and use a plate heat exchanger for efficient air cooling. Detailed cooling-water, air-connection, power, dimensions and weight data are provided per model.

How It Works & Product Features
  • Water-cooled refrigeration cycle with plate heat exchanger for effective heat transfer.
  • KDL and KDH configurations presented separately: KDL table focuses on cooling-water, air-connection and weight; KDH table includes precooling, cooling connections and dimensions.
  • Designed for medium-capacity compressed-air pretreatment where cooling water is available.


Main Technical Specifications
  • Rated flow range: 17 - 110 m3/min.
  • Working pressure: 0.2 - 1.0 MPa.
  • Power supply: 3-phase, 50 Hz, 380 V.
  • Refrigeration compressor power: 3.1 kW to 15.0 kW depending on model.
  • Air connections: DN65 to DN150.


Models & Specifications — KDL Water-Cooled Subseries (table)
Model | Flow (m3/min) | Working Pressure | Power Supply | Refrigeration Compressor Power (kW) | Cooling-Water Connection / Flow | Air Connection | Weight (kg)
KDL-150W | 17 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 3.1 | RC1" / 1.8 t/h | DN65 | 165
KDL-200W | 23 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 3.6 | RC1" / 2.4 t/h | DN65 | 195
KDL-250W | 27 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 4.5 | RC1" / 3 t/h | DN80 | 280
KDL-300W | 34 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 5.4 | RC1-1/2" / 3.7 t/h | DN80 | 360
KDL-400W | 45 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 7.4 | RC1-1/2" / 5.5 t/h | DN100 | 450
KDL-500W | 55 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 8.0 | RC1-1/2" / 6 t/h | DN100 | 580
KDL-600W | 65 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 9.4 | RC1-1/2" / 7 t/h | DN125 | 650
KDL-800W | 87 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 11.0 | RC1-1/2" / 9 t/h | DN150 | 750
KDL-1000W | 110 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 15.0 | RC2" / 12 t/h | DN150 | 960

Models & Specifications — KDH Water-Cooled Subseries (table)
Model | Flow (m3/min) | Working Pressure | Power Supply | Refrigeration Compressor Power (kW) | Precooling / Cooling-Water Connection and Flow | Air Connection | Dimensions L×W×H (mm) | Weight (kg)
KDH-150W | 17 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 3.1 | Precooling: ZG1-1/2" / 3 t/h; Cooling: RC1" / 1.8 t/h | DN65 | 700 × 800 × 1240 | 210
KDH-200W | 23 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 3.6 | Precooling: ZG1-1/2" / 3.6 t/h; Cooling: RC1" / 2.4 t/h | DN65 | 750 × 800 × 1240 | 260
KDH-250W | 27 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 4.5 | Precooling: ZG1-1/2" / 4 t/h; Cooling: RC1" / 3 t/h | DN80 | 750 × 800 × 1240 | 320
KDH-300W | 34 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 5.4 | Precooling: ZG1-1/2" / 5.0 t/h; Cooling: RC1-1/2" / 3.7 t/h | DN80 | 850 × 900 × 1340 | 460
KDH-400W | 45 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 7.4 | Precooling: ZG2" / 6.5 t/h; Cooling: RC1-1/2" / 5.5 t/h | DN100 | 850 × 950 × 1490 | 550
KDH-500W | 55 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 8.0 | Precooling: ZG2" / 8.2 t/h; Cooling: RC1-1/2" / 6 t/h | DN100 | 1000 × 1100 × 1560 | 640
KDH-600W | 65 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 9.4 | Precooling: ZG2" / 9.9 t/h; Cooling: RC1-1/2" / 7 t/h | DN125 | 1400 × 900 × 1640 | 760
KDH-800W | 87 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 11.0 | Precooling: ZG2" / 11.5 t/h; Cooling: RC1-1/2" / 9 t/h | DN150 | 1700 × 1000 × 1740 | 870
KDH-1000W | 110 | 0.2 - 1.0 MPa | 3-phase / 50 Hz / 380 V | 15.0 | Precooling: ZG2-1/2" / 13 t/h; Cooling: RC2" / 12 t/h | DN150 | 2100 × 1800 × 1850 | 1160

Applications
Designed for medium-capacity compressed-air pretreatment where cooling water is available, such as industrial compressed-air stations, process plants and central utilities.

Technical Specifications
  • Series: KDL and KDH water-cooled refrigerated air dryers with plate heat exchanger.
  • Rated flow range: 17 - 110 m3/min (models KDL‑150W/KDH‑150W to KDL‑1000W/KDH‑1000W).
  • Working pressure: 0.2 - 1.0 MPa.
  • Power supply: 3-phase, 50 Hz, 380 V.
  • Refrigeration compressor power: 3.1 kW to 15.0 kW depending on model.
  • Cooling-water connections and flows vary by model (examples: RC1" / 1.8 t/h up to RC2" / 12 t/h). KDH models include separate precooling and cooling connections.
  • Air connections: DN65 to DN150.
  • Dimensions and weights are model-specific; weight range approx. 165 kg to 1160 kg.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.