video corpo

Laboratory sterilizer HT323
steamUHT

Laboratory sterilizer - HT323 - OMVE Lab & Pilot Equipment - steam / UHT
Laboratory sterilizer - HT323 - OMVE Lab & Pilot Equipment - steam / UHT
Laboratory sterilizer - HT323 - OMVE Lab & Pilot Equipment - steam / UHT - image - 2
Add to favorites
Compare this product

Characteristics

Laboratory/process
laboratory
Sterilization method
steam
Other characteristics
UHT
Temperature range

160 °C
(320 °F)

Weight

350 kg
(771.6 lb)

Width

1,300 mm
(51.18 in)

Height

2,000 mm
(78.74 in)

Description

Product description
Direct steam injection (DSI) requires highly accurate steam control. The addition of a flash tank and flash tank pump in many DSI systems complicates control and cleaning. OMVE has designed a fully sanitary DSI system with a high level of automation to simplify operation and hygiene management. The system is available as a standalone unit or can be fully controlled through the HT320 system. Nominal capacity ranges from 20 to 1000 L/h.

Unique features
  • Hygienic design
  • Extremely easy to operate
  • Fully CIP and SIP ready
  • High level of automation
  • 20 bar flash tank pump outlet pressure
  • 0.2 bar(a) vacuum for maximum cooling in the flash tank

Downloads
  • HT223 & HT323 DSI Systems: Advanced In-Line Sterilization Solutions (PDF)
  • Heat Treatment range (PDF)

Heat treatment range (related products)
  • HT223 Laboratory DSI System
  • HT207/HT208 Lab Can Retort
  • HT323 Direct UHT Pilot System with Steam Injection
  • HT226 SSHE System
  • HT324 Steam Infusion / Injection UHT Pilot System
  • HT220DSI Direct/ Indirect HTST/UHT Lab System
  • HT220 Indirect HTST/UHT Lab System
  • HT320 Indirect HTST/UHT Pilot System
  • HT326 Indirect UHT/HTST Pilot System with SSHE
  • HT205 Spray Pasteurizer

Technical specifications
  • Technology: Direct Steam Injection (DSI), fully sanitary design
  • Operation: High level of automation, user-friendly control
  • Integration: Available as standalone or fully controlled through HT320 system
  • Nominal capacity: 20–1000 L/h
  • Flash tank pump outlet pressure: 20 bar
  • Flash tank vacuum: 0.2 bar(a) for maximum cooling
  • CIP/SIP: Fully CIP and SIP ready
  • Design emphasis: Hygienic construction and easy cleaning
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.